본문 바로가기
KERD
논문KCI 등재

신속한 적조 예찰이 가능한 형광 측정시스템 개발

Development of a Fluorescence Measurement System Capable of Rapid Red Tide Monitoring

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류공학일반

초록

The occurrence of harmful algae on the coast of Korea has been a cause of damage to the aquaculture industry and deterioration ofthe coastal ecosystem environment. A method is required to predict their outbreak in real-time at the site. Therefore, this study attemptedto develop a small hybrid optical sensor and real-time monitoring system based on LiDAR that can be used in the field and laboratoryand can be applied to various platforms. FMS-L specifically suggested the amount of Chlorophyll a (Chl a) in the sample by measuring andanalyzing the fluorescence emitted by the irradiating light. The accuracy of FMS-L was verified by measuring the concentrations of standardChlorophyll a substances and Margalfidinium polykirkoids. In addition, the precision was verified by comparing the measurement results ofFMS-L using commercial equipment Phyto-PAM-II. This equipment is compact and easy to move. Therefore, it can be easily applied to fieldsurveys, allows short time measurements (10 s), and can be applied at a distance of 10 m from the measurement site.

Abstract

The occurrence of harmful algae on the coast of Korea has been a cause of damage to the aquaculture industry and deterioration ofthe coastal ecosystem environment. A method is required to predict their outbreak in real-time at the site. Therefore, this study attemptedto develop a small hybrid optical sensor and real-time monitoring system based on LiDAR that can be used in the field and laboratoryand can be applied to various platforms. FMS-L specifically suggested the amount of Chlorophyll a (Chl a) in the sample by measuring andanalyzing the fluorescence emitted by the irradiating light. The accuracy of FMS-L was verified by measuring the concentrations of standardChlorophyll a substances and Margalfidinium polykirkoids. In addition, the precision was verified by comparing the measurement results ofFMS-L using commercial equipment Phyto-PAM-II. This equipment is compact and easy to move. Therefore, it can be easily applied to fieldsurveys, allows short time measurements (10 s), and can be applied at a distance of 10 m from the measurement site.

참고문헌 (3)

  1. H. J. Yoon, "Meteorological information for red tide : Technical development of red tide prediction in the Korean coastal areas by eteorological factors", J. Korea Inst. Inf. Commun. Eng., 9(4), pp.844~853 (2005)
  2. E. Kim, "Characteristics of Backscattering of Harmful Algae Using Underwater Ultrasound", J. Acoust. Soc. Korea, 24(8), pp.447~453 (2005)

관련 논문AI추천

이 간행물의 다른 논문 (9건)