Some results of experimental investigation conducted to assess the effect of cement composite strength and ductility on the shear behavior and crack-damage mitigation of stud connections between existing reinforced concrete frame in school buildings and seismic strengthening elements from cyclically direct shear tests are described. The cement composite strengths include 50 for medium strength and 70 MPa for high strength. Two types of cement composites, strain-hardening cement composite (SHCC) and non-shrinkage mortar, are used for stud shear connection specimens. The special SHCCs are reinforced with hybrid 0.2% polyethylene (PE) and 1.3% polyvinyl alcohol (PVA) fibers at the volume fraction and exhibits tensile strain capacity ranging from 0.2 to 0.5%. Test result indicates that SHCC improves the seismic performance and crack-damage mitigation of stud shear connections compared with stud connections with non-shrinkage mortar. However, the performance enhancement in SHCC stud connections with transverse and longitudinal reinforcements is less notable for those without additional reinforcement.
Abstract
Some results of experimental investigation conducted to assess the effect of cement composite strength and ductility on the shear behavior and crack-damage mitigation of stud connections between existing reinforced concrete frame in school buildings and seismic strengthening elements from cyclically direct shear tests are described. The cement composite strengths include 50 for medium strength and 70 MPa for high strength. Two types of cement composites, strain-hardening cement composite (SHCC) and non-shrinkage mortar, are used for stud shear connection specimens. The special SHCCs are reinforced with hybrid 0.2% polyethylene (PE) and 1.3% polyvinyl alcohol (PVA) fibers at the volume fraction and exhibits tensile strain capacity ranging from 0.2 to 0.5%. Test result indicates that SHCC improves the seismic performance and crack-damage mitigation of stud shear connections compared with stud connections with non-shrinkage mortar. However, the performance enhancement in SHCC stud connections with transverse and longitudinal reinforcements is less notable for those without additional reinforcement.
참고문헌 (7)
- "Result notice of the promotion of public facilities seismic strengthening existing measures in 2011" (2012)[URL]
- 이강석, "비선형요구내력스펙트럼을 이용한 저층 R", C 건물의 내진성능 평가법, 2011, pp.15(3), 106~115[DOI]
- Ahn, Tae-Sang, "Efficient Seismic Retrofit of Retrofit of Existing Structures", Journal of the Architectural Institute of Korea, 52(10), pp.62~69 (2008)
- 류승현, "국내 기존 학교건축물의 내진보강 후 비선형 거동특성", 한국구조물진단유지관리공학회 논문집, 15(1), pp.243~253 (2011), 한국구조물진단유지관리공학회
- 윤길호, "현장타설 끼움 전단벽 및 철골가새를 활용한 기존 학교 건물의 내진보강", 교육시설, 19(4), pp.21~28 (2012), 한국교육시설학회[DOI]
- Japan civil Manabu Concert, "Multiple Fine Cracks Type Fiber Reinforced Cement Composite Material Design", Construction Guidelines (draft), 16~18 (2008)
- Japan General Building Research Laboratory structural part, "Seismic strengthening design and construction guidelines of the wall of the sim concrete", ~ (2001)