끼움벽과 단주효과를 고려한 학교건축물의 내진성능평가
Seismic Performance Evaluation of School Building Short Column Effect
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
In the case of low-rise buildings in seismic performance evaluation, lateral force resistance of the pillars affects the seismic performance of the building. Evaluation of the seismic performance of the column is determined by the holding performance is evaluated by comparing the shear strength and bending strength it was destroyed bylow intensity. In case of the school building, in order to install the large windows for ventilation and lighting of the partition walls are located between the pillars. The case of the pillars of these, shear failure occurs in the event of an earthquake is often, in the seismic performance evaluation, partition wall and the wall of the shim is evaluated ignoring, pillar of the general pillars If you have to calculate the results of the seismic performance distorted that are destroyed by bending behavior can be evaluated as often. Results of the study, when assessed by distinguishing the effective length of the column, it was found that when a seismic load is applied, it is possible to accurately predict the failure mode, reliable results of seismic performance evaluation of the school building.
Abstract
In the case of low-rise buildings in seismic performance evaluation, lateral force resistance of the pillars affects the seismic performance of the building. Evaluation of the seismic performance of the column is determined by the holding performance is evaluated by comparing the shear strength and bending strength it was destroyed bylow intensity. In case of the school building, in order to install the large windows for ventilation and lighting of the partition walls are located between the pillars. The case of the pillars of these, shear failure occurs in the event of an earthquake is often, in the seismic performance evaluation, partition wall and the wall of the shim is evaluated ignoring, pillar of the general pillars If you have to calculate the results of the seismic performance distorted that are destroyed by bending behavior can be evaluated as often. Results of the study, when assessed by distinguishing the effective length of the column, it was found that when a seismic load is applied, it is possible to accurately predict the failure mode, reliable results of seismic performance evaluation of the school building.
참고문헌 (9)
- Oh, Chang-Hak, "Lesson of Wenchuan Earthquake in China", Jourmal of KSEA, 32(87), pp.32~35 (2008)
- 김해진, "아라미드 스트립을 이용한 학교건축물의 내진성능 보강방안에 관한 실험적 연구", 한국안전학회지, 25(3), pp.100~106 (2010), 한국안전학회
- Nehrp Guidelines for the Seismic Rehabilitation of Buildings, FEMA 273, "Applied Technology Council (ATC-33 Project)", Buildings Seismic Safety Council, ~
- Eval uation of Earthquake Damaged Concrete and Masonry Wall buildings, FEMA 306, "Applied Technology Council (ATC-43 Project)", The Partnership for Response and Recovery, ~
- 유한국, "상세재해지도를 고려한 경기지역 학교건축물의 내진성능평가", 한국안전학회지, 24(4), pp.66~73 (2009), 한국안전학회
- Concrete Design Code, "Korea Concrete Institute", ~ (2012)
- Korea Building Code, "Ministry of Land, Infrastructure and Transport", ~ (2009)
- Sinan Altin, "An experimental study on strengthening of masonry infilled RC frames using diagonal CFRP strips", Composites Part B: engineering, 39(4), pp.680~693 (2008)
- Sheilh, S.A., "A Performance -Based Approach for the Design of Confining in Tie Columns", ACI Structural Journal, pp.421~431 (1997)