외부온도 노출에 대한 PCM 축냉 덕트의 성능 특성에 대한 해석적 연구

Performance Characteristics of Phase-Change Material Cold-Storage Duct Exposed to Outside Temperature

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류과학기술학

초록

Recently, side-by-side refrigerators are becoming commercialized because of their left and right compartments. In addition, refrigerators and freezers are becoming commercialized because they can be opened from the top and bottom. However, when a power failure occurs or the set temperature is reached, a refrigerator is not supplied with power. At this time, when the refrigerator is used, the food becomes stale owing to the high external temperature. Hence, a phase-change material (PCM) cold-storage duct needs to be utilized in a refrigerator to prevent this situation. In this study, temperature variations of a PCM cold-storage duct were analyzed when refrigeration inside was exposed to the outdoor temperature. The PCM cold-storage duct was exposed to 25 °C for 60 min. The PCM cold-storage temperature changed from 1.5 to 4.8 °C at the top and bottom, respectively, and -14.7 to -8.2 °C at the left and right sides, respectively. Additionally, the cooling air in the PCM cold-storage duct started to coagulate from the upper side having a large heat-exchange area and solidified from the side to the center with the coagulation nucleus.

Abstract

Recently, side-by-side refrigerators are becoming commercialized because of their left and right compartments. In addition, refrigerators and freezers are becoming commercialized because they can be opened from the top and bottom. However, when a power failure occurs or the set temperature is reached, a refrigerator is not supplied with power. At this time, when the refrigerator is used, the food becomes stale owing to the high external temperature. Hence, a phase-change material (PCM) cold-storage duct needs to be utilized in a refrigerator to prevent this situation. In this study, temperature variations of a PCM cold-storage duct were analyzed when refrigeration inside was exposed to the outdoor temperature. The PCM cold-storage duct was exposed to 25 °C for 60 min. The PCM cold-storage temperature changed from 1.5 to 4.8 °C at the top and bottom, respectively, and -14.7 to -8.2 °C at the left and right sides, respectively. Additionally, the cooling air in the PCM cold-storage duct started to coagulate from the upper side having a large heat-exchange area and solidified from the side to the center with the coagulation nucleus.

참고문헌 (4)

  1. XU LEI, "냉동트럭용 강제대류방식 PCM 냉동모듈의 방냉성능 최적화에 관한 연구", 설비공학 논문집, 25(11), pp.624~630 (2013), 대한설비공학회[DOI]
  2. Jun, Y. H., "Development and Field Test of the PCM Cold Stroage System to apply Nighttime Electric Power to Refrigeration Warehouse", Proceeding of SAREK, pp.751~754 (2015)
  3. Jun, Y. H., "Development and Field Test of a Refrigeration Truck Using a Forced Convection Type PCM Cold Storage System", SAREK Summer Annual Conference, pp.130~133 (2016)
  4. ANSYS Inc, "ANSYS Fluent Theory Guide Release 15.0", ~ (2013)

관련 논문AI추천

이 간행물의 다른 논문 (12건)