A60급 구획 적용 격벽 관통용 관의 열전달 특성 II: 관 재질 및 단열재 종류에 따른 방화시험

Heat Transfer Characteristics of Bulkhead Penetration Piece for A60 Class Compartment II: Fire Resistance Test for Piece Material and Insulation Types

0

조회

0

다운로드

7

인용

0

참고문헌

키워드

주제분류해양공학

초록

In the case of a fire accident on a ship or an offshore plant, the design of the bulkhead penetration piece must be verified via a fire test procedure (FTP), as specified by the Maritime Safety Committee (MSC). The purpose of this study is to verify both the numerical analysis results and the design specifications for penetration pieces that could be applied to the A60 class bulkhead division. In this study, the FTP was carried out in accordance with the test procedure prescribed in the MSC regulation. In order to review the fire resistance performance according to the material type, bulkhead penetration pieces for the FTP were made from brass, carbon steel for machine structures (S45C), and austenite stainless steel (SUS316). In addition, spray-type insulation and mechanical fastener-type insulation were applied to investigate the fire resistance performance according to the type of insulation. To verify the heat transfer numerical analysis results for the A60 class bulkhead penetrating piece from this test study, the design specifications of the penetrating piece material and the insulation type applicable to a ship and an offshore plant were identified.

Abstract

In the case of a fire accident on a ship or an offshore plant, the design of the bulkhead penetration piece must be verified via a fire test procedure (FTP), as specified by the Maritime Safety Committee (MSC). The purpose of this study is to verify both the numerical analysis results and the design specifications for penetration pieces that could be applied to the A60 class bulkhead division. In this study, the FTP was carried out in accordance with the test procedure prescribed in the MSC regulation. In order to review the fire resistance performance according to the material type, bulkhead penetration pieces for the FTP were made from brass, carbon steel for machine structures (S45C), and austenite stainless steel (SUS316). In addition, spray-type insulation and mechanical fastener-type insulation were applied to investigate the fire resistance performance according to the type of insulation. To verify the heat transfer numerical analysis results for the A60 class bulkhead penetrating piece from this test study, the design specifications of the penetrating piece material and the insulation type applicable to a ship and an offshore plant were identified.

참고문헌 (9)

  1. 최정민, "FRP 선박 기관실 난연성 향상을 위한 추가 방열재의 화재성능비교", 한국마린엔지니어링학회지, 38(9), pp.1150~1155 (2014), 한국마린엔지니어링학회[DOI]
  2. 최태진, "코밍 방열 두께 및 블레이드 방열 유무에 따른 방화 댐퍼의 내화성능에 관한 실험적 연구", 한국마린엔지니어링학회지, 37(4), pp.431~437 (2013), 한국마린엔지니어링학회[DOI]
  3. Grigonis, M., "Fire Resistance Tests of Various Fire Protective Coatings", Materials Science, 17(1), pp.93~98 (2011)
  4. International Organization for Standardization, "Fire Resistance Tests - Elements of Building Construction", ISO 834-1, ~ (1999)
  5. 장성철, "해양플랜트용 H-120 Class 파이어 댐퍼의 성능 실험", 한국기계가공학회지, 13(2), pp.131~136 (2014), 한국기계가공학회[DOI]
  6. "Overview of materials for Brass" (2019)[URL]
  7. MSC, "Adoption of the International Code for Application of Fire Test Procedures", MSC.307(88), ~ (2010)
  8. 박우창, "A60급 구획 적용 격벽 관통용 관의 열전달 특성 I: 관의 설계에 따른 과도 열해석", 한국해양공학회지, 32(5), pp.310~323 (2018), 한국해양공학회[DOI]
  9. Yu, J. S., "An Experimental Study on Fire-Resistant Boom", Journal of the Korean Society of Marine Environmental Engineering, 3(2), pp.25~32 (2000)