The density profile measurement technology by gamma transmission has been widelyused to diagnose processes in the field of refinery and petrochemical industry. This technology canreveal a clue and position of abnormal phenomenon of industrial processes during their operation. In this paper, the feasibility of the gamma transmission technology for detecting changes in theamount of fluid in a distillation column was evaluated by using Monte Carlo simulations. The simulationsassumed that 60Co (1.17, 1.33 MeV) sources and NaI (Tl) detectors (Φ5×5 cm) are locatedin opposite sides of a column and it concurrently moves in vertical direction. To determine thedependency of a spatial resolution on aperture size of a collimator, the simulation model for atray in a column were simulated with the aperture sizes of 1 and 2 cm. The thickness of the highdensity area including a tray and fluid was 7.6 cm in the simulation. The spatial resolution of thetray was 8.2 and 8.5 cm, respectively. As a result, it was revealed that the conventional density profilemeasurement technique is not able to show the deviation of liquid level on a tray in a column

Abstract

The density profile measurement technology by gamma transmission has been widelyused to diagnose processes in the field of refinery and petrochemical industry. This technology canreveal a clue and position of abnormal phenomenon of industrial processes during their operation. In this paper, the feasibility of the gamma transmission technology for detecting changes in theamount of fluid in a distillation column was evaluated by using Monte Carlo simulations. The simulationsassumed that 60Co (1.17, 1.33 MeV) sources and NaI (Tl) detectors (Φ5×5 cm) are locatedin opposite sides of a column and it concurrently moves in vertical direction. To determine thedependency of a spatial resolution on aperture size of a collimator, the simulation model for atray in a column were simulated with the aperture sizes of 1 and 2 cm. The thickness of the highdensity area including a tray and fluid was 7.6 cm in the simulation. The spatial resolution of thetray was 8.2 and 8.5 cm, respectively. As a result, it was revealed that the conventional density profilemeasurement technique is not able to show the deviation of liquid level on a tray in a column

참고문헌 (7)

  1. 김재호, "Gamma Absorption Technique를 이용한 Trayed Column의 가동 중 내부 밀도분포 측정에 의한유체 유동상태 진단", 방사선방어학회지, 33(1), pp.35~40 (2008), 대한방사선방어학회
  2. 정성희, "감마선을 이용한 가동 중 증류탑 진단실험", 공업화학, 13(1), pp.19~24 (2002), 한국공업화학회
  3. SY MINH TUAN HOANG, "EXPERIMENTAL VALIDATION OF THE BACKSCATTERINGGAMMA-RAY SPECTRA WITH THE MONTE CARLO CODE", Nuclear Engineering and Technology, 43(1), pp.13~18 (2011), 한국원자력학회
  4. Johnson P, "Some applications of radioisotopes in the chemical industry", Chem. Ind, 19, pp.750~756 (1963)
  5. Kim HS, "Study of flow characteristics in a secondary clarifier by numerical simulation and radioisotope tracer technique", Appl. Radiat. Isot, 63, pp.519~526 (2005)
  6. Kim JB, "Development of transportable gamma-ray tomographic system for industrial application", Nucl. Instrum. Methods Phys. Res. A, 693, pp.203~208 (2012)
  7. Legoupil S, "Determination of the detection process in an experimental tomograph for industrial flow visualization using radioactive tracers", IEEE Trans. Nucl. Sci, 43(2), pp.751~760 (1996)

관련 논문AI추천

이 간행물의 다른 논문 (18건)