본문 바로가기
KERD
논문KCI 등재

방사성동위원소 위치에 따른 산업용 SPECT 성능에미치는 영향

Effect of Radioisotope Position on Performance of Industrial SPECT

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Demand of fluid flow visualization has increased in industrial processes, because medicalimaging technology is highly developed. As a part of the industrial process imaging technology,industrial single photon emission computed tomography (SPECT) system was developed to measurethe cross-sectional distribution of the process fluid. The SPECT consists of 36 NaI (Tl) detectorswith the hexagonal configuration. Reconstructed images were acquired for various positionsof radioactive source to estimate SPECT device performance. To evaluate the reliability of theexperimental results, the Monte Carlo simulation results are compared with experimental results. In general, the experimental and simulation results were consistent. However, as the source positionwas getting far from the center of the reactor, the accuracy of reconstructed images was compromised. It seems to be due to the inconsistent spatial resolution of the collimators according tothe source position.

Abstract

Demand of fluid flow visualization has increased in industrial processes, because medicalimaging technology is highly developed. As a part of the industrial process imaging technology,industrial single photon emission computed tomography (SPECT) system was developed to measurethe cross-sectional distribution of the process fluid. The SPECT consists of 36 NaI (Tl) detectorswith the hexagonal configuration. Reconstructed images were acquired for various positionsof radioactive source to estimate SPECT device performance. To evaluate the reliability of theexperimental results, the Monte Carlo simulation results are compared with experimental results. In general, the experimental and simulation results were consistent. However, as the source positionwas getting far from the center of the reactor, the accuracy of reconstructed images was compromised. It seems to be due to the inconsistent spatial resolution of the collimators according tothe source position.

참고문헌 (7)

  1. 문진호, "방사성동위원소를 이용한 정유설비 내 촉매유동 특성 및수직밀도 분포 측정", 방사선산업학회지, 5(4), pp.317~323 (2011), (사)한국방사선산업학회
  2. 정성희, "감마선을 이용한 가동 중 증류탑 진단실험", 공업화학, 13(1), pp.19~24 (2002), 한국공업화학회
  3. Childlow K, "Rapid emission tomography reconstruction", Proceedings of the Third International Workshop on Volume Graphics 2003, pp.15~26 (2003)
  4. Hjertaker B, "Level measurement and control strategies for subsea separators", J. Electron. Imaging, 10, pp.679~689 (2001)
  5. Industrial process gamma tomography, "IAEA", 46~47, pp.IAEATECDOC-1589 (2008)
  6. Lange K, "EM reconstruction algorithms for emission and transmission tomography", J. Comput. Assist. Tomogr, 8(2), pp.306~316 (1984)
  7. Legoupil S, "Determination of the detection process in an experimental tomograph for industrial flow visualization using radioactive tracers", IEEE Nucl. Sci, 43(2), pp.751~760 (1996)

관련 논문AI추천

이 간행물의 다른 논문 (12건)