본문 바로가기
KERD
논문KCI 등재

쇄골 골절 부위에 따른 축사방향 촬영 최적화 연구

Optimization of Axio-oblique Projection according to Clavicle Fracture Site

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Treatment of clavicle fractures requires more precise imaging for accurate diagnosisand treatment, depending on the tendency to change from conservative to surgical treatment. Inaddition, an accurate examination method considering the sigmoidal anatomy and distortion of theclavicle is needed. Therefore, the clavicle study was taken separately before and AP, PA, Oblique,and axial projection. The purpose of the present invention is to provide an accurate imagingmethod according to the fracture pattern by verifying an examination method simultaneously axialimages in a patient̓s oblique position. Sixteen models of Robison clavicle fracture classificationwere made using a 3D printer. In the experimental method, an image was obtained by providing anangle of incidence toward the head from 0~30° in units of 10°. Images were acquired from 0 to 30°in 10° increments toward the head of each rotation angle at 10, 20, 30 and 40° rotational angles. Inthe image evaluation, each radiotechnologist who had more than 10 years of experience evaluatedeach image three times. Evaluation items are 1) Can you accurately assess the alignment? 2) Arethe descriptions of shortening and clavicle fractures well represented? Was evaluated on a 5-pointscale. The patient̓s posture provided an angle of incidence at the oblique position, which waseffective in aligning, shortening, and fracture shape of the midshaft and lateral fractures of theclavicle. The midhaft fracture was especially effective for simple and multigragmnetary fractures. Axio-oblique projection of clavicle fractures is an effective test.

Abstract

Treatment of clavicle fractures requires more precise imaging for accurate diagnosisand treatment, depending on the tendency to change from conservative to surgical treatment. Inaddition, an accurate examination method considering the sigmoidal anatomy and distortion of theclavicle is needed. Therefore, the clavicle study was taken separately before and AP, PA, Oblique,and axial projection. The purpose of the present invention is to provide an accurate imagingmethod according to the fracture pattern by verifying an examination method simultaneously axialimages in a patient̓s oblique position. Sixteen models of Robison clavicle fracture classificationwere made using a 3D printer. In the experimental method, an image was obtained by providing anangle of incidence toward the head from 0~30° in units of 10°. Images were acquired from 0 to 30°in 10° increments toward the head of each rotation angle at 10, 20, 30 and 40° rotational angles. Inthe image evaluation, each radiotechnologist who had more than 10 years of experience evaluatedeach image three times. Evaluation items are 1) Can you accurately assess the alignment? 2) Arethe descriptions of shortening and clavicle fractures well represented? Was evaluated on a 5-pointscale. The patient̓s posture provided an angle of incidence at the oblique position, which waseffective in aligning, shortening, and fracture shape of the midshaft and lateral fractures of theclavicle. The midhaft fracture was especially effective for simple and multigragmnetary fractures. Axio-oblique projection of clavicle fractures is an effective test.

참고문헌 (9)

  1. Allman FL Jr, "Fractures and ligamentous injuries of the clavicle and its articulation", J. Bone Joint Surg. Am, 49(4), pp.774~784 (1967)
  2. Court-Browm CM, "Rockwood and green’s fractures in adults", pp.1427~1429 (2015), Wolters Kluwer Healt
  3. 문성철, "쇄골 외측 단 골절의 긴장대 강선 고정술: 방사선학적 분석 및 임상적 결과", 대한골절학회지, 27(2), pp.127~135 (2014), 대한골절학회
  4. Neer CS 2nd, "Fractures of the distal third of the clavicle", Clin. Orthop. Relat. Res, 58, pp.43~50 (1968)
  5. 오주한, "쇄골 골절 치료의 최근 경향", 대한 견주관절 학회지, 15(1), pp.43~51 (2012), 대한견주관절학회
  6. 오왕균, "보급형 3D 프린터로 제작한 쇄골 골절 모델을 이용한 정형외과 수술에 대한 유용성과 활용가능성 평가", 방사선기술과학, 37(3), pp.203~209 (2014), 대한방사선과학회
  7. Reza Omid, "Measurement of Clavicle Fracture Shortening Using Computed Tomography and Chest Radiography", Clinics in Orthopedic Surgery, 8(4), pp.367~372 (2016), 대한정형외과학회
  8. 박득현, "응급센터에 내원한 외상환자에서 간과된 골절의 요인 분석", 대한외상학회지, 22(1), pp.37~43 (2009), 대한외상학회
  9. Robinson CM, "Fracture of the clavicle in the adult", J. Bone Joint Sur. Br, 80, pp.476~484 (1998)

관련 논문AI추천

이 간행물의 다른 논문 (16건)