본문 바로가기
KERD
논문KCI 등재

PCB 비파괴 검사에 있어서 단일 에너지 소스와이중 에너지 소스의 영상비교를 위한 엑스선 스펙트럼 분석

Energy Spectrum Analysis between Single and Dual Energy Source X-ray Imaging for PCB Non-destructive Test

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Reliability of printed circuit board (PCB), which is based on high integrated circuittechnology, is having been important because of development of electric and self-driving car. Inorder to answer these demand, automated X-ray inspection (AXI) is best solution for PCB nondestructivetest. PCB is consist of plastic, copper, and, lead, which have low to high Z-numbermaterials. By using dual energy X-ray imaging, these materials can be inspected accurately andefficiently. Dual energy X-ray imaging, that have the advantage of separating materials, however,need some solution such as energy separation method and enhancing efficiency because PCB hasmaterials that has wide range of Z-number. In this work, we found out several things by analysisof X-ray energy spectrum. Separating between lead and combination of plastic and copper is onlypossible with energy range not dose. On the other hand, separating between plastic and copperis only with dose not energy range. Moreover the copper filter of high energy part of dual X-rayimaging and 50 kVp of low energy part of dual X-ray imaging is best for efficiency.

Abstract

Reliability of printed circuit board (PCB), which is based on high integrated circuittechnology, is having been important because of development of electric and self-driving car. Inorder to answer these demand, automated X-ray inspection (AXI) is best solution for PCB nondestructivetest. PCB is consist of plastic, copper, and, lead, which have low to high Z-numbermaterials. By using dual energy X-ray imaging, these materials can be inspected accurately andefficiently. Dual energy X-ray imaging, that have the advantage of separating materials, however,need some solution such as energy separation method and enhancing efficiency because PCB hasmaterials that has wide range of Z-number. In this work, we found out several things by analysisof X-ray energy spectrum. Separating between lead and combination of plastic and copper is onlypossible with energy range not dose. On the other hand, separating between plastic and copperis only with dose not energy range. Moreover the copper filter of high energy part of dual X-rayimaging and 50 kVp of low energy part of dual X-ray imaging is best for efficiency.

참고문헌 (8)

  1. 문순환, "AFVI를 위한 PCB PAD의 자동 광학 검사", J. Opt. Soc. Korea Summer Meeting (2006)
  2. 이준재, "B-spline 표면 근사화 기반의 3차원 솔더 페이스트 검사", Journal of the Korean Society for Industrial and Applied Mathematics, 10(1-1), pp.31~45 (2006), 한국산업응용수학회
  3. 한종철, "Single-shot dual-energy x-ray imaging with a flat-panel sandwich detector for preclinical imaging", Current Applied Physics, 14(12), pp.1734~1742 (2014), 한국물리학회
  4. Kim KH, "New sandwich type detector module and its characteristics for dual x-ray baggage inspection system", Nucl. Sci. Symp. Conf. Rec., NSS'07, 2, pp.1191~1194 (2007)
  5. Macdonald RD, "Design and implementation of a dual-energy X-ray imaging system for organic material detection in an airport security application", Photonics West 2001Electron. Imaging. Int. Soc. Opt. Photonics, pp.31~41 (2001)
  6. Rebuffel V, "Dual-energy X-ray imaging:benefits and limits", Insight Nondestr. Test. Condition Monit., 49(10), pp.589~594 (2007)
  7. Dual Energy X Ray Absorptiometry for Bone Mineral Density and Body Composition Assessment, "Shepherd JA", International Atomic Energy Agency, 30~35, pp.IAEA Human Health Series No. 15 (2010)
  8. Yun S, "Feasibility of active sandwich detectors for single-shot dual-energy imaging", Proc. SPIE, Med. Imaging Phy. Med. Imaging, 9033, pp.99335T~90335T (2014)

관련 논문AI추천

이 간행물의 다른 논문 (7건)