국제표준 기반의 공간선량계 (서베이미터)의 방사선 성능시험 및 평가 기술 연구

A Study on the Radiation Performance Testing and Evaluation Technology for Survey Meter Based on International Standards

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

The goal of this study is to secure the technology to carry out international standardsbased measurements, testing, and verification of survey meters and radiation safety managementequipment for safe management of radiation. Based on IEC 60846-1, the international standardfor evaluating the performance of radiation devices, we derived radiation performancerequirements and test methods for dose dependability, energy dependance, direction dependency,linearity, accuracy, overload, reaction time, and alarm. Performance evaluation was conductedusing the test methods that were derived by using gamma and x-ray reference survey devicesbased on international standards. Based on this, we first secured the technology level andperformance criterion for the commercialized domestic survey meter, then we verified whetherthe survey meter conforms to the standard requirement by evaluating it with the test method andperformance standard stipulated in the international standard. We were able to verify that theperformance condition proposed by the manufacturer was more narrowly specified compared tothe IEC performance condition. In general, an empirical evaluation of the technical specificationsrecommended by the manufacturer and the test items specified by IEC confirmed that they weresatisfied within the reference conditions. It is expected that the result of this research on theintroduction of a radiation equipment evaluation system suitable for these international standardswill secure the technology to carry out international standards based measurements, testing, andverification of radiation protection measurement equipment for radiation safety management.

Abstract

The goal of this study is to secure the technology to carry out international standardsbased measurements, testing, and verification of survey meters and radiation safety managementequipment for safe management of radiation. Based on IEC 60846-1, the international standardfor evaluating the performance of radiation devices, we derived radiation performancerequirements and test methods for dose dependability, energy dependance, direction dependency,linearity, accuracy, overload, reaction time, and alarm. Performance evaluation was conductedusing the test methods that were derived by using gamma and x-ray reference survey devicesbased on international standards. Based on this, we first secured the technology level andperformance criterion for the commercialized domestic survey meter, then we verified whetherthe survey meter conforms to the standard requirement by evaluating it with the test method andperformance standard stipulated in the international standard. We were able to verify that theperformance condition proposed by the manufacturer was more narrowly specified compared tothe IEC performance condition. In general, an empirical evaluation of the technical specificationsrecommended by the manufacturer and the test items specified by IEC confirmed that they weresatisfied within the reference conditions. It is expected that the result of this research on theintroduction of a radiation equipment evaluation system suitable for these international standardswill secure the technology to carry out international standards based measurements, testing, andverification of radiation protection measurement equipment for radiation safety management.

참고문헌 (7)

  1. "ANSI", HPS N13.11:2009, Personnel Dosimetry Performance - Criteria for Testing
  2. "Radiation protection instrumentation - Ambient and", or directional dose equivalent (rate) meters and, IEC 60846-1:2009, ~
  3. "Radiation protection instrumentation - Measurement of personal dose equivalents Hp (10) and Hp (0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters", IEC 61526:2010, ~
  4. "General requirements for the competence of testing and calibration laboratories", ISO
  5. "Radiological protection - X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 1: Radiation characteristics and production methods", ISO 4037-4:2019, ~
  6. "Nuclear energy - Reference beta-particle radiation - Part 1: Methods of production", ISO 6980-1:2006, ~
  7. "Reference neutron radiations - Part 1: Characteristics and methods of production", ISO 8529-1:2001, ~

관련 논문AI추천

기준 방사선장 구축을 위한 방사선 조사장치의 특성 및선질 평가에 대한 연구권다영, 노성진, 민제호, 한기택(사)한국방사선산업학회 · 방사선산업학회지2022 · 제16권 제4호저선량과 고선량 측정구간 변환이 가능한 모바일 방사선 측정시스템 개발 및 평가김보길, 김석현, 김정훈, 이건주, 이홍연, 한상준대한방사선과학회 · Journal of Radiological Science and Technology2022 · 제45권 제1호원자력 시설 주변 방사선량 감시를 위한 양방향 이동형 방사선측정 시스템 개발김보길, 김재욱, 문주현, 이홍연, 주한영, 최진식(사)한국방사선산업학회 · 방사선산업학회지2022 · 제16권 제4호방사성 금속폐기물 오염도 측정 및 분류 시스템 구축을 위한 검출기 성능평가노성진, 임영기, 한기택(사)한국방사선산업학회 · 방사선산업학회지2021 · 제15권 제4호Ambient dose equivalent monitoring in the vicinity of a nuclear facility with dosemeters based on Geiger-Müller tubesĐaletić Miloš, Komatina Ivana, Kržanović Nikola, Radumilo Vesna, Živanović Miloš한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제5호국제표준규격의 137Cs 감마선장에서 전리함선량계 종류에 따른 공기커마율 측정 및 평가결과의 유효성 검증안현, 강영록, 계용욱, 김효진, 목성윤, 백정화, 이지은, 이창근, 장희진, 조월순(사)한국방사선산업학회 · 방사선산업학회지2025 · 제19권 제3호