본문 바로가기
KERD
논문KCI 등재

미신고지역의 환경 방사선 검출을 위한 전개형 검출기 개발

Development of Deployable Detector for Environmental Radiation Detection in Unknown Areas

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

For the denuclearization, nuclear activities must be reported and the reporteddocuments must be confirmed through nuclear disarmament verification process. Samplingfrom undeclared area is an essential task of the verification to obtain information about theconcealment of nuclear material. However, it is not possible to get the environmental radioactivityinformation of undeclared areas, so the safety of workers for sampling cannot be guaranteed. Therefore, before collecting samples, it is necessary to secure the information about radioactivityof the sampling region through the radiation measurement. In this study, we propose a compactgamma detection probe that can be transported by drones and distributed over a wide area in ashort period of time. A plastic scintillator was applied to reduce weight and increase efficiency. In addition, the total weight and power consumption of the probe were optimized by applying ameasurement method that counts photons generated from the scintillator. The performance of theprobe was evaluated under the same dose conditions as the actual measurement environment. Itwas confirmed that the probe developed in this study exceeded more than twice the count value ofbackground radiation at 25 meters. In addition, it was confirmed that the count value increased ata linear rate as the dose rate. As a result, it is possible to estimate the dose rate from the measuredcount value.

Abstract

For the denuclearization, nuclear activities must be reported and the reporteddocuments must be confirmed through nuclear disarmament verification process. Samplingfrom undeclared area is an essential task of the verification to obtain information about theconcealment of nuclear material. However, it is not possible to get the environmental radioactivityinformation of undeclared areas, so the safety of workers for sampling cannot be guaranteed. Therefore, before collecting samples, it is necessary to secure the information about radioactivityof the sampling region through the radiation measurement. In this study, we propose a compactgamma detection probe that can be transported by drones and distributed over a wide area in ashort period of time. A plastic scintillator was applied to reduce weight and increase efficiency. In addition, the total weight and power consumption of the probe were optimized by applying ameasurement method that counts photons generated from the scintillator. The performance of theprobe was evaluated under the same dose conditions as the actual measurement environment. Itwas confirmed that the probe developed in this study exceeded more than twice the count value ofbackground radiation at 25 meters. In addition, it was confirmed that the count value increased ata linear rate as the dose rate. As a result, it is possible to estimate the dose rate from the measuredcount value.

참고문헌 (15)

  1. 김정호, "플라스틱 섬광체를 이용한 방사선 검출기의 검출 효율을 높이기 위한 섬광체 연마 기술 연구", 전기전자학회논문지, 18(4), pp.456~462 (2014), 한국전기전자학회[DOI]
  2. 박혜민, "감마선 분광분석을 위한 실리콘 광 증배소자 기반 Ce:GAGG 섬광검출기의 분광특성 연구", 방사선방어학회지, 40(2), pp.73~78 (2015), 테스트학회
  3. 소동섭, "프로그램 93+ 2 IAEA 보장조치 강화방안과 그 대책", 1996 춘계학술발표회 논문집 한국원자력학회, pp.463~468 (1996)
  4. 신상훈, "감마선 분포 측정을 위한 섬광필름 기반의 감마 영상 검출기 제작 및 성능평가", 센서학회지, 24(3), pp.202~207 (2015), 한국센서학회[DOI]
  5. Blix H, "Verification of nuclear non-proliferation: Securing the future", IAEA Bulletin, 34(1), pp.2~5 (1992)
  6. Carlson J, "Verification of DPRK Nuclear Disarmament: The Pros and Cons of Non-Nuclear-Weapon States (specifically, the ROK) Participating in This Verification Program", J-PAND, 2(2), pp.535~554 (2019)
  7. Delacroix D, "Radionuclide and radiation protection data handbook 2002", Radiation Protection Dosimetry, 98(1), pp.1~168 (2002)
  8. Knoll GF, "Radiation detection and measurement" (2010), John Wiley & Sons
  9. 이덕재, "현장 중심의 화학테러·사고 대응을 위한 피해 영향 범위 평가 개선 방안 연구", 융합정보논문지, 10(8), pp.127~136 (2020), 중소기업융합학회[DOI]
  10. Verification Technologies for the International Nuclear Nonproliferation Regime, "Miller KA", Los Alamos National Lab, ~, pp.No. LAUR-13-22697 (2013)
  11. Oldham M, "Initial experience with optical-CT scanning of RadBall Dosimeters", JPCS, 250(1), pp.012079~ (2010), IOP Publishing
  12. 박혜민, "진단용 무선 감마선 프로브 개발 및 유용성 평가", 전자공학회논문지, 52(2), pp.173~181 (2015), 대한전자공학회
  13. Rose M, "Infotech@ Aerospace 2011", pp.1557~ (2011)
  14. Vax E, "ERMS-Environmental Radiation Monitoring System" (2008)
  15. Yamamoto S, "A compact and high efficiency GAGG well counter for radiocesium concentration measurements", Nucl. Instrum. Methods A, 753, pp.19~23 (2014)

관련 논문AI추천

저선량과 고선량 측정구간 변환이 가능한 모바일 방사선 측정시스템 개발 및 평가김보길, 김석현, 김정훈, 이건주, 이홍연, 한상준대한방사선과학회 · Journal of Radiological Science and Technology2022 · 제45권 제1호원자력 시설 주변 방사선량 감시를 위한 양방향 이동형 방사선측정 시스템 개발김보길, 김재욱, 문주현, 이홍연, 주한영, 최진식(사)한국방사선산업학회 · 방사선산업학회지2022 · 제16권 제4호Development of a drone-mounted remote radiation imaging system문진호, 박영주, 서동휘, 염정열, 이기성, 이인범, 이학재, 전강우, 정만희, 정성희, 정재원한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제5호중성자선과 감마선 동시측정이 가능한 휴대용 계측시스템 개발에 관한 연구김재현, 김희경, 박수연, 정영석, 홍용호대한방사선과학회 · Journal of Radiological Science and Technology2020 · 제43권 제6호Real-time wireless marine radioactivity monitoring system using a SiPM-based mobile gamma spectroscopy mounted on an unmanned marine vehicle장미, 백승재, 서정민, 이민선, 임종명, 차혜미, Kim Soo Mee한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제6호현장형 사용후핵연료 연소도 측정 시스템 개발을 위한 예비실험김태영, 박혜민, 송양수, 이운장, 장대헌, 함철민(사)한국방사선산업학회 · 방사선산업학회지2025 · 제19권 제1호

이 간행물의 다른 논문 (15건)