본문 바로가기
KERD
논문KCI 등재

수정체 방사선 방호에 관한 규제기준 및 기술기준 검토

Review on Regulatory and Technical Standards of Radiation Protection for Lens of the Eye Si Young Kim1,*, Seok-Ju

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

of the eye for radiation workers from 150 to 20 mSv in April 2011. This trend of lowering the equivalentdose limit for radiation workers has been observed worldwide, including international organizations such as theInternational Atomic Energy Agency (IAEA), International Organization for Standardization (ISO) and the EuropeanCommission (EC). In 2016, the Nuclear Safety and Security Commission of South Korea published research resultsthat included a proposal for lowering the equivalent dose limit of lens of the eye for radiation workers in line with theICRP recommendation. However, as of now, South Korea’s Nuclear Safety Act and related regulations still specifyan annual equivalent dose limit of lens of the eye as 150 mSv for radiation workers. The IAEA and ISO have issuedguidelines regarding radiation protection for lens of the eye and recommended a dose level for the lens of the eye at 5or 6 mSv per year for periodic monitoring of the equivalent dose for the lens of the eye.

Abstract

of the eye for radiation workers from 150 to 20 mSv in April 2011. This trend of lowering the equivalentdose limit for radiation workers has been observed worldwide, including international organizations such as theInternational Atomic Energy Agency (IAEA), International Organization for Standardization (ISO) and the EuropeanCommission (EC). In 2016, the Nuclear Safety and Security Commission of South Korea published research resultsthat included a proposal for lowering the equivalent dose limit of lens of the eye for radiation workers in line with theICRP recommendation. However, as of now, South Korea’s Nuclear Safety Act and related regulations still specifyan annual equivalent dose limit of lens of the eye as 150 mSv for radiation workers. The IAEA and ISO have issuedguidelines regarding radiation protection for lens of the eye and recommended a dose level for the lens of the eye at 5or 6 mSv per year for periodic monitoring of the equivalent dose for the lens of the eye.

참고문헌 (20)

  1. The 2007 Recommendations of the International Commission on Radiological Protection, "ICRP", ~, pp.ICRP 103 (2007)
  2. 1990 Recommendations of the International Commission on Radiological Protection, "ICRP", ~, pp.ICRP 60 (1991)
  3. ICRP statement of tissue reactions and early and late effects of radiation in normal tissues and organs - Threshold doses for tissue reactions in a radiation protection context, "ICRP", ~, pp.ICRP 118 (2012)
  4. ICRP 103 신권고 및 IAEA GSR Part 3 국내도입을 위한 기술기준 최적화 연구개발, "원자력안전위원회", 대한방사선방어학회, ~, pp.대한방사선방어학회, 2016-25호 (2017)
  5. Minamoto A, "Cataracts in atomic bomb survivors", International Journal of Radiation Biology, 80, pp.339~345 (2004)
  6. Hall P, "Lenticular opacities in individuals exposed to ionising radiation in infancy", Radiation Research, 152, pp.190~195 (1999)
  7. Radiation Protection and Safety of Radiation Sources:International Basic Safety Standards, "IAEA", IAEA, ~, pp.General Safety Requirements Part 3 (2014)
  8. EU, "Council Directive 2013", 59 EURATOM laying down basic safety standards for protection against the dangers arising from exposure to ionising radiation, and repealing Directives 89, Euratom, 90, pp.641, Euratom, 96[DOI]
  9. Staff Requirements - SECY-08-0197 - Options to Revise Radiation Protection Regulations and Guidance with Respect to the 2007 Recommendations of the International Commission on Radiological Protection, "U. S. NRC", U.S. Nuclear Regulatory Commission, ~, pp.SRM-SECY-08-0197 (2007)
  10. U. S. Federal Register, "Advance notice of proposed rulemaking;request for comments. 79(143)", 43284~43300 (2014)
  11. U. S. Federal Register, "Rulemaking Activities Being Discontinued by the NRC. 81(249)", 95410~95412 (2016)
  12. ISO, "Radiological protection - Procedures for monitoring the dose to the lens of the eye, the skin and the extremities", ISO 15382:2015, ~ (2015)
  13. Lie Ø, "Assessment of Effective Dose and dose to the lens of the eye for the interventional cardiologist", Radiation Protection Dosimetry, 132(3), pp.313~318 (2008)
  14. Implications for Occupational Radiation Protection of the New Dose Limit for the Lens of the Eye, "IAEA", ~, pp.IAEA TECDOC 1731 (2013)
  15. Gualdrini G, "Fluence to Hp(3) conversion coefficients for neutrons from thermal to 15 MeV", Radiation Protection Dosimetry (2013)[DOI]
  16. IRPA, "IRPA Guidance on implementation for eye dose monitoring and eye protection of workers", ~ (2017)
  17. Yokoyama, "The Japan health physics society guideline on dose monitoring for the lens of the eye", Journal of Radiation Protection and Research, 47(1), pp.1~7 (2022)
  18. "Guideline on dose monitoring for the lens of eye" (2020)[URL]
  19. Jacques Dubeau, "Current stauts of eye-lens dosimetry in Canada", Journal of Radiological Protection, 42 (2022)
  20. CNSC, "Dosimetry, volume 1: Ascertaining Occupational Dose. REGCOD-2.7.2", ~ (2021)

관련 논문AI추천

이 간행물의 다른 논문 (11건)