수치해석 및 모형실험을 통한 초고층 공동주택의 화재안전성 평가
Numerical Study and Model Experiment on the Fire Safety Assessment of a High-Rise Building
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
In this study a sixty six-storied high-rise building was selected as a target model, and the fire safety was assessed by using evacuation simulations in accordance with the number of evacuation floors. Also the propagation of toxic gas was analyzed by scale model experiments and numerical simulations. As results of the evacuation simulation about the actual high-rise building, case 3 with two evacuation floor(20th floor, 40th floor) was considered as the most effective, when considering the investment costs and the safety of evacuation. As a result of model experiments and simulations, it was confirmed that the time of upward moving of toxic gas takes longer, as the number of evacuation floors increases.
Abstract
본 연구에서는 지상 66층 초고층 공동주택을 대상모델로 선정하여 피난대피층 수에 따라 총 4가지 피난대피 시뮬레이션을 통해 화재안전성을 평가하였다. 또한 모형실험과 수치 시뮬레이션을 통해 유해가스 전파특성을 분석하였다. 본 연구에서 실제 초고층공동주택을 대상으로 한 피난대피시뮬레이션 수행 결과, 투자비용과 피난안정성을 고려하였을 때, 피난대피층이 2개(20층, 40층)인 case 3이 가장 효과적이라고 판단된다. 또한 모형실험과 시뮬레이션 결과 피난대피층의 수가 증가함에 따라 유해가스의 유동시간이 길어지는 것을 확인할 수 있었다.
참고문헌 (6)
- 국토해양부, "제정 2009.7.16. 제34조(직통계단의 설치). 건축법시행령 제21629호", ~ (2009)
- 박현구, "초고층 공동주택의 건축적 특성 분석", 한국주거학회논문집, 18(1), pp.11~18 (2007), 한국주거학회
- 이승철, "계단형 공동주택 화재 시 독성가스 전파 저감에 관한 수치해석적 연구", 춘계학술논문발표회 논문집, pp.255~258 (2008), 한국화재소방학회
- 최재필, "초고층 건축물의 ‘대피층’ 및 ‘대피공간’ 개념 도입 방안", 대한건축학회논문집 계획계, 21(11), pp.147~154 (2005), 대한건축학회
- 홍이표, "계단형 공동주택 화재 시 재실자 피난특성 및 연기거동에 관한 연구", 한국화재소방학회 춘계학술논문발표회 논문집, pp.156~161 (2006)
- 황재호, "화재피난 시뮬레이션" (2009), 동화기술