국가지정 입원치료 격리병상 시설적격성 및 환경개선효과 분석에 관한 연구
A Study on the Facility Eligibility Inspection & Effect of Environment Improvement for National Inpatient Isolation Units
0
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Purpose: This study is for the facility eligibility and improvement evaluation analysis for the patient care environment of 7 facilities which has national inpatient isolation units. Methods: For the evaluation, first of all, the patient care environment of national inpatient isolation units are scrutinized by the checklist which is used on from 2014 with the 4 fields of criteria : architectural planning and layout, general requirement and condition for operating the negative pressured isolated patient room, HVAC system, and waste water discharging system. Finally, the evaluation results are compared with that of 2014. Results: The result shows that the average value of facility eligibility is 89.3 percent and which is 8.9 percent higher than the value before the MERS occurred. Implications: It is clear that facility remodeling of 7 institutions is being performed continuously, and the result of facility eligibility evaluation is reflected on design of a new 21 national inpatient isolation units those are going to be constructed from 2016. Therefore, it is expected that this study is used as a practical reference to establish the criteria of patient care environment management and safety management for both infectious disease outbreak and general service condition.
Abstract
Purpose: This study is for the facility eligibility and improvement evaluation analysis for the patient care environment of 7 facilities which has national inpatient isolation units. Methods: For the evaluation, first of all, the patient care environment of national inpatient isolation units are scrutinized by the checklist which is used on from 2014 with the 4 fields of criteria : architectural planning and layout, general requirement and condition for operating the negative pressured isolated patient room, HVAC system, and waste water discharging system. Finally, the evaluation results are compared with that of 2014. Results: The result shows that the average value of facility eligibility is 89.3 percent and which is 8.9 percent higher than the value before the MERS occurred. Implications: It is clear that facility remodeling of 7 institutions is being performed continuously, and the result of facility eligibility evaluation is reflected on design of a new 21 national inpatient isolation units those are going to be constructed from 2016. Therefore, it is expected that this study is used as a practical reference to establish the criteria of patient care environment management and safety management for both infectious disease outbreak and general service condition.
참고문헌 (10)
- CDC, "Guidelines for Environmental Infection Control in Health-Care Facilities", ~ (2003)
- CDC, "Biosafety in Microbiological and Biomedical Laboratories", ~ (2007)
- European Network for Highly Infectious Diseases, "Manual for the safe and appropriate management of Highly Infectious Disease patients in isolation facilities", ~
- 홍진관, "국가지정 입원치료 격리병상 시설적격성 평가분석에 관한 연구", 설비공학 논문집, 27(10), pp.506~514 (2015), 대한설비공학회[DOI]
- KCDC, "Guidelines for laboratory biosafety", ~ (2008)
- KCDC, "SARS, AI in human, PI, National inpatient isolation units management guideline", ~ (2011)
- KCDC, "Statement of verification for biosafety level3 laboratory", ~ (2012)
- "Laboratory Biosafety Guidelines, Health Canada", ~ (2004)
- Minister of Health and Welfare, "Guideline for recombinant gene experiment", ~ (2014)
- WHO, "Laboratory Biosafety Manual", ~ (2004)