Performance Evaluation of Anyplex plus MTB/NTM and AdvanSure TB/NTM for the Detection of Mycobacterium tuberculosis and Nontuberculous Mycobacteria

1

조회

0

다운로드

4

인용

0

참고문헌

키워드

초록

Background: Polymerase chain reaction (PCR) methods from direct specimen are widely used for the rapid and accurate detection of mycobacteria infection. In this study, we evaluated two domestically developed detection kits for Mycobacterium tuberculosis (MTB) and nontuberculous mycobacteria (NTM) using real-time PCR. Methods: A total of 348 samples from patients with suspected tuberculosis were tested with real-time PCR over seven months. We performed real-time PCR using the recently developed Anyplex plus MTB/NTM Detection kit (Seegene) with the CFX 96TM Real- time PCR System (Bio-Rad Laboratories) and the conventional AdvanSure TB/NTM real-time PCR kit (LG Life Sciences) with the SLAN Real-time PCR detection system (LG Life Sciences) to evaluate their performance for detecting MTB and NTM. Results: The two real-time PCR systems showed 96.8% concordance rate for MTB-positive, NTM-positive, and negative results. Based on culture results, the sensitivity and specificity for the detection of MTB using PCR were 71.0% and 94.9% for Anyplex plus, and 78.1% and 93.9% for AdvanSure, respectively. For the detection of NTM, the sensitivity and specificity were 33.3% and 98.4% for Anyplex plus, and 51.7% and 97.9% for AdvanSure. Both PCR systems showed high MTB positive results in bronchial washing and sputum samples. Conclusion: In detecting MTB and NTM, Anyplex plus MTB/NTM (Seegene) and AdvanSure TB/NTM real-time PCR (LG Life Sciences) showed high concordance rate with each other in all samples. Therefore both detection kits can be used as rapid and reliable detection tool for MTB. (Ann Clin Microbiol 2015;18:-51)

Abstract

Background: Polymerase chain reaction (PCR) methods from direct specimen are widely used for the rapid and accurate detection of mycobacteria infection. In this study, we evaluated two domestically developed detection kits for Mycobacterium tuberculosis (MTB) and nontuberculous mycobacteria (NTM) using real-time PCR. Methods: A total of 348 samples from patients with suspected tuberculosis were tested with real-time PCR over seven months. We performed real-time PCR using the recently developed Anyplex plus MTB/NTM Detection kit (Seegene) with the CFX 96TM Real- time PCR System (Bio-Rad Laboratories) and the conventional AdvanSure TB/NTM real-time PCR kit (LG Life Sciences) with the SLAN Real-time PCR detection system (LG Life Sciences) to evaluate their performance for detecting MTB and NTM. Results: The two real-time PCR systems showed 96.8% concordance rate for MTB-positive, NTM-positive, and negative results. Based on culture results, the sensitivity and specificity for the detection of MTB using PCR were 71.0% and 94.9% for Anyplex plus, and 78.1% and 93.9% for AdvanSure, respectively. For the detection of NTM, the sensitivity and specificity were 33.3% and 98.4% for Anyplex plus, and 51.7% and 97.9% for AdvanSure. Both PCR systems showed high MTB positive results in bronchial washing and sputum samples. Conclusion: In detecting MTB and NTM, Anyplex plus MTB/NTM (Seegene) and AdvanSure TB/NTM real-time PCR (LG Life Sciences) showed high concordance rate with each other in all samples. Therefore both detection kits can be used as rapid and reliable detection tool for MTB. (Ann Clin Microbiol 2015;18:-51)

참고문헌 (12)

  1. Joint Committee for the Revision of Korean Guidelines for Tuberculosis Korea Centers for Disease Control and Prevention, "Korean Guidelines for Tuberculosis", Korea Centers for Disease Control and Prevention, 30~31 (2014)
  2. Jang MA, "Annual report on the external quality assessment of diagnostic genetics in Korea", J Lab Med Qual Assur, 36, pp.71~83 (2014)
  3. Korea Centers for Disease Control and Prevention, "Manual of Laboratory Tests for Tuberculosis", Korea Centers for Disease Control and Prevention, 75~80 (2013)
  4. Joint Committee for the Revision of Korean Guidelines for Tuberculosis Korea Centers for Disease Control and Prevention, "Korean Guidelines for Tuberculosis", Korea Centers for Disease Control and Prevention, 227~228 (2014)
  5. Shinnick TM, "National plan for reliable tuberculosis laboratory services using a systems approach. Recommendations from CDC and the Association of Public Health Laboratories Task Force on Tuberculosis Laboratory Services", MMWR Recomm Rep, 54, pp.1~12 (2005)
  6. Centers for Disease Control and Prevention, "Updated guidelines for the use of nucleic acid amplification tests in the diagnosis of tuberculosis", MMWR Morb Mortal Wkly Rep, 58, pp.7~10 (2009)
  7. Broccolo F, "Rapid diagnosis of mycobacterial infections and quantitation of Mycobacterium tuberculosis load by two real-time calibrated PCR assays", J Clin Microbiol, 41, pp.4565~4572 (2003)
  8. 장호은, "실시간-중합효소연쇄반응을 이용한 결핵균의 검출", Annals of Laboratory Medicine, 28(2), pp.103~108 (2008), 대한진단검사의학회
  9. 임진숙, "Multicenter Evaluation of Seegene Anyplex TB PCR for the Detection of Mycobacterium tuberculosis in Respiratory Specimens", Journal of Microbiology and Biotechnology, 24(7), pp.1004~1007 (2014), 한국미생물·생명공학회[DOI]
  10. 이준형, "핵균 검출과 항결핵제 감수성 검사를 위한 Anyplex Plus MTB", NTM 및 MDR-TB Detection 키트의 성능 평가, 2014, pp.17(4), 115~122[DOI]
  11. 이혜영, "Assessment of the Quantitative Ability of AdvanSure TB", NTM Real-Time PCR in Respiratory Specimens by Comparison with Phenotypic Methods, 2014, pp.34(1), 51~55[DOI]
  12. 조선영, "Comparison of Diagnostic Performance of Three Real-Time PCR Kits for Detecting Mycobacterium Species", Yonsei Medical Journal, 52(2), pp.301~306 (2011), 연세대학교의과대학

관련 논문AI추천

결핵균과 비결핵 항산균 검출을 위한 AdvanSure TB/NTM Plus Real-Time PCR의 평가소민경, 이미애, 정혜선, 함초롱대한임상미생물학회 · Annals of Clinical Microbiology2020 · 제23권 제2호Comparison of AdvanSure TB/NTM PCR and COBAS TaqMan MTB PCR for Detection of Mycobacterium tuberculosis Complex in Routine Clinical Practice기승정, 서순팔, 신종희, 양동욱, 원은정, 조원형, 최현정대한진단검사의학회 · Annals of Laboratory Medicine2015 · 제35권 제3호핵균 검출과 항결핵제 감수성 검사를 위한 Anyplex Plus MTB/NTM 및 MDR-TB Detection 키트의 성능 평가김보현, 이미경, 이준형대한임상미생물학회 · Annals of Clinical Microbiology2014 · 제17권 제4호Multicenter Evaluation of Seegene Anyplex TB PCR for the Detection of Mycobacterium tuberculosis in Respiratory Specimens구선회, 김자영, 김종완, 김지명, 손용학, 임진숙, 임춘화, 조현정한국미생물·생명공학회 · Journal of Microbiology and Biotechnology2014 · 제24권 제7호LG AdvanSure TB/NTM Real-Time PCR Kit의 항산균 진단 수행 능력 평가어영, 김영근, 김효열, 오기진, 윤갑준, 장인호, 황상선대한임상미생물학회 · Annals of Clinical Microbiology2011 · 제14권 제2호Clinical Usefulness of Real-time PCR and Amplicor MTB PCRAssays for Diagnosis of Tuberculosis김미경, 서동춘, 이미애, 정채림대한임상미생물학회 · Annals of Clinical Microbiology2008 · 제11권 제1호

이 간행물의 다른 논문 (5건)