Background: Timely intervention in the treatment of bloodstream infection is important for prescription of appropriate antimicrobials. With prompt determination of the antimicrobial susceptibility of a causative agent, rapid antimicrobial susceptibility test (AST) can help select the appropriate antimicrobial therapy. This clinical study is for evaluation of the clinical performance of the QMAC-dRAST for rapid AST directly from positive blood culture (PBC)s with Gram-positive cocci. Methods: A total of 115 PBC samples with Gram- positive organisms (76 Staphylococcus spp. and 39 Enterococcus spp.) were evaluated by the QMAC- dRAST system, and their pure culture isolates were evaluated by the MicroScan WalkAway (Beckman Coulter, USA) as the comparative AST system. Thirteen antimicrobial agents were included, and the agreement and discrepancy rates of the QMAC- dRAST system (Quantamatrix Inc., Republic of Korea) compared to the MicroScan WalkAway were calculated. To resolve discrepancies, the broth microdilution method was performed. Results: The QMAC-dRAST system exhibited a categorical agreement rate of 94.9% (1,126/1,187) and an essential agreement rate of 98.3% (1,167/1,187). The QMAC-dRAST system yielded very major (false- susceptible) errors at 1.0% (5/485), major (false-resistant) errors at 1.3% (9/693), and minor errors at 4.0% (47/1,187) compared to the MicroScan WalkAway. The QMAC-dRAST system significantly eliminated 30 hours of total turnaround time by combination of direct inoculation of PBC and an image-based approach. Conclusion: The results of the QMAC-dRAST system were highly accurate. Thereby, the QMAC-dRAST may provide essential information to accelerate therapeutic decisions for earlier and adequate antibiotic treatment and patient management in clinical settings. (Ann Clin Microbiol 2018;21:-19)

Abstract

Background: Timely intervention in the treatment of bloodstream infection is important for prescription of appropriate antimicrobials. With prompt determination of the antimicrobial susceptibility of a causative agent, rapid antimicrobial susceptibility test (AST) can help select the appropriate antimicrobial therapy. This clinical study is for evaluation of the clinical performance of the QMAC-dRAST for rapid AST directly from positive blood culture (PBC)s with Gram-positive cocci. Methods: A total of 115 PBC samples with Gram- positive organisms (76 Staphylococcus spp. and 39 Enterococcus spp.) were evaluated by the QMAC- dRAST system, and their pure culture isolates were evaluated by the MicroScan WalkAway (Beckman Coulter, USA) as the comparative AST system. Thirteen antimicrobial agents were included, and the agreement and discrepancy rates of the QMAC- dRAST system (Quantamatrix Inc., Republic of Korea) compared to the MicroScan WalkAway were calculated. To resolve discrepancies, the broth microdilution method was performed. Results: The QMAC-dRAST system exhibited a categorical agreement rate of 94.9% (1,126/1,187) and an essential agreement rate of 98.3% (1,167/1,187). The QMAC-dRAST system yielded very major (false- susceptible) errors at 1.0% (5/485), major (false-resistant) errors at 1.3% (9/693), and minor errors at 4.0% (47/1,187) compared to the MicroScan WalkAway. The QMAC-dRAST system significantly eliminated 30 hours of total turnaround time by combination of direct inoculation of PBC and an image-based approach. Conclusion: The results of the QMAC-dRAST system were highly accurate. Thereby, the QMAC-dRAST may provide essential information to accelerate therapeutic decisions for earlier and adequate antibiotic treatment and patient management in clinical settings. (Ann Clin Microbiol 2018;21:-19)

참고문헌 (22)

  1. Schefold JC, "Sepsis: time has come to focus on the later stages", Med Hypotheses, 71, pp.203~208 (2008)[DOI]
  2. Gherardi G, "Comparative evaluation of the Vitek-2 Compact and Phoenix systems for rapid identification and antibiotic susceptibility testing directly from blood cultures of Gram-negative and Gram-positive isolates", Diagn Microbiol Infect Dis, 72, pp.20~31 (2012)[DOI]
  3. Barenfanger J, "Clinical and financial benefits of rapid bacterial identification and antimicrobial susceptibility testing", J Clin Microbiol, 37, pp.1415~1418 (1999)
  4. Munoz-Davila MJ, "Comparative evaluation of Vitek 2 identification and susceptibility testing of Gram-negative rods directly and isolated from BacT", ALERT-positive blood culture bottles, 2012, pp.31, 663~669
  5. Bazzi AM, "Direct identification and susceptibility testing of positive blood cultures using high speed cold centrifugation and Vitek II system", J Infect Public Health, 10, pp.299~307 (2017)[DOI]
  6. 조성진, "Direct Identification and Antimicrobial Susceptibility Testing of Bacteria From Positive Blood Culture Bottles by Matrix-Assisted Laser Desorption", Ionization Time-of-Flight Mass Spectrometry and the Vitek 2 System, 2016, pp.36(2), 117~123[DOI]
  7. Pulido MR, "Progress on the development of rapid methods for antimicrobial susceptibility testing", J Antimicrob Chemother, 68, pp.2710~2717 (2013)[DOI]
  8. Ling TK, "Evaluation of the VITEK 2 system for rapid direct identification and susceptibility testing of gramnegative bacilli from positive blood cultures", J Clin Microbiol, 41, pp.4705~4707 (2003)[DOI]
  9. de Cueto M, "Use of positive blood cultures for direct identification and susceptibility testing with the Vitek 2 system", J Clin Microbiol, 42, pp.3734~3738 (2004)[DOI]
  10. Ligozzi M, "Evaluation of the VITEK 2 system for identification and antimicrobial susceptibility testing of medically relevant gram-positive cocci", J Clin Microbiol, 40, pp.1681~1686 (2002)[DOI]
  11. Funke G, "Use of the BD PHOENIX Automated Microbiology System for direct identification and susceptibility testing of gram-negative rods from positive blood cultures in a three-phase trial", J Clin Microbiol, 42, pp.1466~1470 (2004)[DOI]
  12. Chen JR, "Rapid identification and susceptibility testing using the VITEK 2 system using culture fluids from positive BacT", ALERT blood cultures, 2008, pp.41, 259~264
  13. Choi J, "Direct, rapid antimicrobial susceptibility test from positive blood cultures based on microscopic imaging analysis", Sci Rep, 7, pp.1148~ (2017)[DOI]
  14. Choi J, "Rapid antibiotic susceptibility testing by tracking single cell growth in a microfluidic agarose channel system", Lab Chip, 13, pp.280~287 (2013)[DOI]
  15. Choi J, "A rapid antimicrobial susceptibility test based on single-cell morphological analysis", Sci Transl Med, 6, pp.267ra174~ (2014)[DOI]
  16. CLSI, "Performance standards for antimicrobial susceptibility testing: Twenty-four informational supplement. CLSI document M100-S24", Clinical and Laboratory Standards Institute, ~ (2014)
  17. Mittman SA, "Comparison of BD Phoenix to Vitek 2, MicroScan MICroSTREP, and Etest for antimicrobial susceptibility testing of Streptococcus pneumoniae", J Clin Microbiol, 47, pp.3557~3561 (2009)[DOI]
  18. Hansen DS, "Direct identification and susceptibility testing of enteric bacilli from positive blood cultures using VITEK (GNI+", GNS-GA), 2002, pp.8, 38~44
  19. Lupetti A, "Saponin promotes rapid identification and antimicrobial susceptibility profiling of Gram-positive and Gram-negative bacteria in blood cultures with the Vitek 2 system", Eur J Clin Microbiol Infect Dis, 32, pp.493~502 (2013)[DOI]
  20. Idelevich EA, "Acceleration of antimicrobial susceptibility testing of positive blood cultures by inoculation of Vitek 2 cards with briefly incubated solid medium cultures", J Clin Microbiol, 52, pp.4058~4062 (2014)[DOI]
  21. Howard WJ, "Vitek GPS card susceptibility testing accuracy using direct inoculation from BACTEC 9240 blood culture bottles", Diagn Microbiol Infect Dis, 24, pp.109~112 (1996)[DOI]
  22. Woods GL, "Evaluation of MicroScan rapid gram-positive panels for detection of oxacillin-resistant staphylococci", J Clin Microbiol, 32, pp.1058~1059 (1994)

관련 논문AI추천

Performance Evaluation of QMAC-dRAST Using Consecutive Positive Clinical Blood Culture Samples권미정, 김대원, 변정현, 용동은, 이혁민, 진봉환, 최희강, 홍기호대한진단검사의학회 · Laboratory Medicine Online2023 · 제13권 제2호European Committee on Antimicrobial Susceptibility Testing-Recommended Rapid Antimicrobial Susceptibility Testing of Escherichia coli, Klebsiella pneumoniae, and Staphylococcus aureus From Positive Blood Culture Bottles용동은, 이혁민, Hong Ki Ho, Kwon Mijung, Park Jong-Min대한진단검사의학회 · Annals of Laboratory Medicine2023 · 제43권 제5호Clinical Usefulness of the QMAC-dRAST System for AmpC β-lactamase-Producing Enterobacterales권미정, 김대원, 변정현, 용동은, 이혁민, 진봉환, 최희강, 홍기호대한임상미생물학회 · Annals of Clinical Microbiology2022 · 제25권 제4호Direct Identification and Antimicrobial Susceptibility Testing of Bacteria From Positive Blood Culture Bottles by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry and the Vitek 2 System박강균, 박동진, 박연준, 조성진, 한경자대한진단검사의학회 · Annals of Laboratory Medicine2016 · 제36권 제2호Same-Day Identification and Antimicrobial Susceptibility Testing of Bacteria in Positive Blood Culture Broths Using Short-Term Incubation on Solid Medium with the MicroFlex LT, Vitek-MS, and Vitek2 Systems김명숙, 용동은, 이경원, 하지혜, 한금희, 홍성국대한진단검사의학회 · Annals of Laboratory Medicine2018 · 제38권 제3호A Direct Rapid Phenotypic Antimicrobial Susceptibility Test Enables Early Selection of Optimal Antibiotics to Treat Bacteremia in COVID-19 Patients박도현, Chang Euijin, Choe Pyoeng Gyun, Kang Chang Kyung, Kim Nam Joong, Kim Taek Soo, Oh Myoung-Don, Park Wan Beom대한감염학회 · Infection and Chemotherapy2021 · 제53권 제4호