Evaluation of Two Commercial Kits for Rapid Pathogen Identification Directly From Positive Blood Cultures by Matrix-Associated Laser Desorption/Ionization Time-of-Flight Mass Spectrometry
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: A bloodstream infection is a life-threatening medical emergency, with a mortality rate of up to 30%. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) can be used to identify pathogens directly from positive blood cultures. Two commercial preparation kits, SepsiTyper (Bruker Daltonics, Germany) and SepsiPrep (ASTA Corp., Korea), and two MALDI-TOF MS systems, MALDI Biotyper Sirius (BrukerDaltonics, Germany) and VITEK MS PRIME (bioMérieux, France), are available in Korea. We examined these kits and MALDI-TOF MS systems to analyze their performance. Methods: We assessed the effectiveness of direct identification using 47 blood cultures and 3 bile cultures positive for microbial growth. The VIRTUO system (bioMérieux, France) was used to incubate the samples after they were collected in Bact/ALERT aerobic and anaerobic bottles. The manufacturers’ protocols were followed for both the SepsiTyper and SepsiPrep kits. Results: The SepsiTyper yielded considerably more accurate identifications than did the SepsiPrep, when utilized in MALDI-TOF MS systems (P = 0.0044). However, the SepsiPrep was easier to use and the results more quickly obtained than with the SepsiTyper. The MALDI Biotyper Sirius produced more accurate identifications with the SepsiTyper than did the VITEK MS PRIME (P = 0.0736). The SepsiTyper enabled the accurate identification of five of sixpolymicrobial cases, utilizing either the MALDI-TOF MS systems. Conclusions: Among the pathogen ID kits tested in this study, the SepsiTyper with MALDI Biotyper Sirius performed the best. In clinical laboratories utilizing VITEK MS PRIME, it is recommended that the either the SepsiTyper or SepsiPrep kit be used for direct identification, while considering certain limitations in terms of performance.
Abstract
Background: A bloodstream infection is a life-threatening medical emergency, with a mortality rate of up to 30%. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) can be used to identify pathogens directly from positive blood cultures. Two commercial preparation kits, SepsiTyper (Bruker Daltonics, Germany) and SepsiPrep (ASTA Corp., Korea), and two MALDI-TOF MS systems, MALDI Biotyper Sirius (BrukerDaltonics, Germany) and VITEK MS PRIME (bioMérieux, France), are available in Korea. We examined these kits and MALDI-TOF MS systems to analyze their performance. Methods: We assessed the effectiveness of direct identification using 47 blood cultures and 3 bile cultures positive for microbial growth. The VIRTUO system (bioMérieux, France) was used to incubate the samples after they were collected in Bact/ALERT aerobic and anaerobic bottles. The manufacturers’ protocols were followed for both the SepsiTyper and SepsiPrep kits. Results: The SepsiTyper yielded considerably more accurate identifications than did the SepsiPrep, when utilized in MALDI-TOF MS systems (P = 0.0044). However, the SepsiPrep was easier to use and the results more quickly obtained than with the SepsiTyper. The MALDI Biotyper Sirius produced more accurate identifications with the SepsiTyper than did the VITEK MS PRIME (P = 0.0736). The SepsiTyper enabled the accurate identification of five of sixpolymicrobial cases, utilizing either the MALDI-TOF MS systems. Conclusions: Among the pathogen ID kits tested in this study, the SepsiTyper with MALDI Biotyper Sirius performed the best. In clinical laboratories utilizing VITEK MS PRIME, it is recommended that the either the SepsiTyper or SepsiPrep kit be used for direct identification, while considering certain limitations in terms of performance.
참고문헌 (19)
- Hattori H, "Epidemiology and risk factors for mortality in bloodstream infections : a single-center retrospective study in Japan", Am J Infect Control, 46, pp.e75~e79 (2018)
- Evans L, "Surviving sepsis campaign : international guidelines for management of sepsis and septic shock 2021", Intens Care Med, 47, pp.1181~1247 (2021)
- Yoon EJ, "Bloodstream infections and carbapenem-resistant Enterobacteriaceae in South Korea", Lancet Infect Dis, 19, pp.931~932 (2019)
- Fre´de´ric S, "Bacterial rapid identification with matrix assisted laser desorption", ionization time-of-flight mass spectrometry : development of an ‘inhouse method’ and comparison with Bruker Sepsityper® kit, 2015, pp.70, 325~330
- Yoo IY, "Clinical performance of ASTA SepsiPrep kit in direct bacterial identification and antimicrobial susceptibility test using MicroIDSys Elite and VITEK-2 system", J Clin Lab Anal, 35, pp.e23744~ (2021)
- Ponderand L, "Evaluation of Rapid Sepsityper® protocol and specific MBT-Sepsityper module(Bruker Daltonics)for the rapid diagnosis of bacteremia and fungemia by MALDI-TOF-MS", Ann Clin Microbiol Antimicrob, 19, pp.60~ (2020)
- Lin HH, "Evaluation of the Rapid Sepsityper protocol and specific MBT-Sepsityper module for the identification of bacteremia and fungemia using Bruker Biotyper MALDI-TOF MS", J Microbiol Immunol Infect, 55, pp.1330~1333 (2022)
- Pranada AB, "Identification of micro-organism from positive blood cultures : comparison of three different short culturing methods to the Rapid Sepsityper workflow", J Med Microbiol, 71, pp.001571~ (2022)
- Fothergill A, "Rapid identification of bacteria and yeasts from positive-blood-culture bottles by using a lysis-filtration method and matrix-assisted laser desorption ionization-time of flight mass spectrum analysis with the SARAMIS database", J Clin Microbiol, 51, pp.805~809 (2013)
- Morgenthaler NG, "Rapid identification of pathogens in positive blood culture of patients with sepsis : review and meta-analysis of the performance of the Sepsityper kit", Int J Microbiol, 2015, pp.1~10 (2015)
- Godmer A, "Revisiting species identification within the Enterobacter cloacae complex by matrix-assisted laser desorption ionization–time of flight mass spectrometry", Microbiol Spectr, 9, pp.e00661-21~ (2021)
- Brady M, "Attributable mortality of hospital-acquired bloodstream infections in Ireland", J Hosp Infect, 96, pp.35~41 (2017)
- Dat VQ, "Bacterial bloodstream infections in a tertiary infectious diseases hospital in Northern Vietnam: aetiology, drug resistance, and treatment outcome", BMC Infect Dis, 17, pp.493~ (2017)
- Goto M, "Overall burden of bloodstream infection and nosocomial bloodstream infection in North America and Europe", Clin Microbiol Infect, 19, pp.501~509 (2013)
- Chen JHK, "Direct bacterial identification in positive blood cultures by use of two commercial matrix-assisted laser desorption ionization–time of flight mass spectrometry systems", J Clin Microbiol, 51, pp.1733~1739 (2013)
- Schieffer KM, "Multicenter evaluation of the SepsityperTM extraction kit and MALDI-TOF MS for direct identification of positive blood culture isolates using the BD BACTECTM FX and VersaTREK® diagnostic blood culture systems", J Appl Microbiol, 116, pp.934~941 (2014)
- Jamal W, "Rapid identification of pathogens directly from blood culture bottles by Bruker matrix-assisted laser desorption laser ionization-time of flight mass spectrometry versus routine methods", Diagn Microbiol Infect Dis, 76, pp.404~408 (2013)
- Prod’hom G, "Matrix-assisted laser desorption ionization-time of flight mass spectrometry for direct bacterial identification from positive blood culture pellets", J Clin Microbiol, 48, pp.1481~1483 (2010)
- Tadros M, "Evaluation of MALDI-TOF mass spectrometry and Sepsityper Kit™for the direct identification of organisms from sterile body fluids in a Canadian pediatric hospital", Can J Infect Dis Med Microbiol, 24, pp.191~194 (2013)
