본문 바로가기
KERD
논문KCI 등재

Prediction of Software-Based Sentence-in-Noise Recognition Thresholds of Hearing-Impaired Listeners

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

Purpose: Although hearing-impaired (HI) listeners often have difficulty understanding in noise as their primary complaints, the speech-in-noise intelligibility test is not conducted as a standard audiologic test battery. This study investigated whether the speech audiometry in quiet accurately reflects the sentence-in-noise intelligibility of HI listeners. Methods: Sixty-two HI listeners participated. All the HI listeners had symmetrical high-frequency hearing loss and bilaterally worn hearing aids. Twenty-five normal-hearing (NH) listeners also participated as a control group. The unaided word and sentence recognition scores (WRS and SRS) were obtained in quiet at individually determined most comfortable loudness level. With bilateral hearing aids, the aided WRS and SRS were evaluated at a normal conversational level. The software-based Korean Matrix sentence in noise test was administered at a fixed level (65 dB SPL) of noise while adjusting the sentence level adaptively based on the listener’s response. The signal-to-noise ratio (SNR) required to achieve 50% intelligibility (speech recognition thresholds, SRTs) was obtained. Results: On average, the aided SRT of HI listeners was 0.1 dB SNR, and the mean SRT of NH adults was -8.91 dB SNR. The Matrix sentence-in-noise intelligibility was not sufficiently explained by the unaided WRS or unaided SRS. Conclusion: A traditional measure of the unaided speech-in-quiet recognition cannot accurately predict the aided speech-in-noise intelligibility. Clinically, a software-based sentence-in-noise intelligibility test is recommended to directly confirm the actual benefits of hearing aid in noisy situations.

Abstract

Purpose: Although hearing-impaired (HI) listeners often have difficulty understanding in noise as their primary complaints, the speech-in-noise intelligibility test is not conducted as a standard audiologic test battery. This study investigated whether the speech audiometry in quiet accurately reflects the sentence-in-noise intelligibility of HI listeners. Methods: Sixty-two HI listeners participated. All the HI listeners had symmetrical high-frequency hearing loss and bilaterally worn hearing aids. Twenty-five normal-hearing (NH) listeners also participated as a control group. The unaided word and sentence recognition scores (WRS and SRS) were obtained in quiet at individually determined most comfortable loudness level. With bilateral hearing aids, the aided WRS and SRS were evaluated at a normal conversational level. The software-based Korean Matrix sentence in noise test was administered at a fixed level (65 dB SPL) of noise while adjusting the sentence level adaptively based on the listener’s response. The signal-to-noise ratio (SNR) required to achieve 50% intelligibility (speech recognition thresholds, SRTs) was obtained. Results: On average, the aided SRT of HI listeners was 0.1 dB SNR, and the mean SRT of NH adults was -8.91 dB SNR. The Matrix sentence-in-noise intelligibility was not sufficiently explained by the unaided WRS or unaided SRS. Conclusion: A traditional measure of the unaided speech-in-quiet recognition cannot accurately predict the aided speech-in-noise intelligibility. Clinically, a software-based sentence-in-noise intelligibility test is recommended to directly confirm the actual benefits of hearing aid in noisy situations.

참고문헌 (24)

  1. Akeroyd, M. A., "International Collegium of Rehabilitative Audiology (ICRA) recommendations for the construction of multilingual speech tests. ICRA Working Group on multilingual speech tests", International Journal of Audiology, 54(Suppl 2), pp.17~22 (2015)
  2. Brand, T., "Efficient adaptive procedures for threshold and concurrent slope estimates for psychophysics and speech intelligibility tests", The Journal of the Acoustical Society of America, 111(6), pp.2801~2810 (2002)
  3. 변성완, "전국의 수련 병원에서 사용하고 있는 한국어 단음절어음표의실태 및 어음 빈도 분석", 대한이비인후-두경부외과학회지, 48(9), pp.1086~1090 (2005), 대한이비인후과학회
  4. 한영권, "A Study on the Korean Conversation Speech Level and Spectrum in Sound-Treated Environment", Audiology and Speech Research, 16(2), pp.133~139 (2020), 한국청각언어재활학회
  5. Hey, M., "Investigation of a matrix sentence test in noise : Reproducibility and discrimination function in cochlear implant patients", International Journal of Audiology, 53(12), pp.895~902 (2014)
  6. International Organization for Standardization, "ISO 8253-1:2010. Acoustics-Audiometric Test Methods-Part 1: Pure-Tone Air and Bone Conduction Audiometry", ISO, ~ (2010)
  7. Killion, M. C., "Fitting hearing aids using clinical prefitting speech measures : An evidence-based review", Journal of the American Academy of Audiology, 16(7), pp.439~447 (2005)
  8. Killion, M. C., "Development of a quick speech-in-noise test for measuring signal-to-noise ratio loss in normal-hearing and hearing-impaired listeners", The Journal of the Acoustical Society of America, 116(4 Pt 1), pp.2395~2405 (2004)
  9. 김경현, "한국어 Matrix 문장 검사 도구 평가: 목록 간 동질성과 단어 위치의 영향에 대한 검증", Audiology and Speech Research, 14(2), pp.100~107 (2018), 한국청각언어재활학회
  10. 김나경, "고정된 신호대잡음비에서의 소음 하 문장인지도의 신뢰도와 타당도에 관한 연구", Audiology and Speech Research, 13(1), pp.62~69 (2017), 한국청각언어재활학회
  11. Kollmeier, B., "The multilingual matrix test: Principles, applications, and comparison across languages: A review", International Journal of Audiology, 54(Suppl 2), pp.3~16 (2015)
  12. Lee, J. H., "Korean Speech Audiometry(KSA)" (2010), Hakjisa
  13. 이재희, "변동형 소음 하 문장인지 평가 도구의 비교", Audiology and Speech Research, 13(1), pp.9~18 (2017), 한국청각언어재활학회
  14. McCormack, A., "Why do people fitted with hearing aids not wear them?", International Journal of Audiolo, 52(5), pp.360~368 (2013)
  15. McRackan, T. R., "Clinical implications of word recognition differences in earphone and aided conditions", Otology and Neurotology, 37(10), pp.1475~1481 (2016)
  16. Mendel, L. L., "Current considerations in pediatric speech audiometry", International Journal of Audiology, 47(9), pp.546~553 (2008)
  17. Mendel, L. L., "Audiologic Evaluation and Management and Speech Perception Assessment" (1997), Singular Publishing
  18. Moon, S. K., "The Korean hearing in noise test", International Journal of Audiology, 47(6), pp.375~376 (2008)
  19. Nilsson, M., "Development of the hearing in noise test for the measurement of speech reception thresholds in quiet and in noise", The Journal of the Acoustical Society of America, 95(2), pp.1085~1099 (1994)
  20. Taylor, B., "Speech-in-noise tests: How and why to include them in your basic test battery", The Hearing Journal, 56(1), pp.40~46 (2003)
  21. Theunissen, M., "Sentence recognition in noise : Variables in compilation and interpretation of tests", International Journal of Audiology, 48(11), pp.743~757 (2009)
  22. Wardenga, N., "Do you hear the noise? The German matrix sentence test with a fixed noise level in subjects with normal hearing and hearing impairment", International Journal of Audiology, 54(Suppl 2), pp.71~79 (2015)
  23. Wilson, R. H., "Clinical experience with the words-in-noise test on 3430 veterans : Comparisons with pure-tone thresholds and word recognition in quiet", Journal of the American Academy of Audiology, 22(7), pp.405~423 (2011)
  24. Yi, D., "Study on the construction and optimization of the Korean matrix sentence materials", Master, pp.2016

관련 논문AI추천