인프라 독립형 가변안내표지판의 효율적 전력 운영 방안 연구
A Study of Effective Power Management for Infrafree Variable Message Sign
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Although the demand of Variable Message Sign(VMS) has become pervasive in fulfilling the ITS policy, there are still several unsolved problematic issues. The most critical ones of them are inequality and inefficiency of providing traffic information. This paper proposes the Infra-free Variable Message Sign in order to provide useful informations such as road condition, weather, and traffic of the area, where constructing the infrastructure of communication and power supply is relatively very hard. First of all, the characteristics of infra-free Variable Message Sign are studied and analyzed in deep because of differences between normal Variable Message Sign and Infra-free Variable Message Sign in the configuration and the operating method due to the nature of the Infra-free Variable Message Sign. Futhermore, for effective power management of operating Infra-free Variable Message Sign with limited power acquired through stand-alone PV system, new battery connection structure and dynamically variable power managements for the differently shown messages on Variable Message Sign are proposed. The proposed structure in this paper can be applied to not only power management for Infra-free Variable Message Sign but also power management for the various applications using parallel connection battery system.
Abstract
Although the demand of Variable Message Sign(VMS) has become pervasive in fulfilling the ITS policy, there are still several unsolved problematic issues. The most critical ones of them are inequality and inefficiency of providing traffic information. This paper proposes the Infra-free Variable Message Sign in order to provide useful informations such as road condition, weather, and traffic of the area, where constructing the infrastructure of communication and power supply is relatively very hard. First of all, the characteristics of infra-free Variable Message Sign are studied and analyzed in deep because of differences between normal Variable Message Sign and Infra-free Variable Message Sign in the configuration and the operating method due to the nature of the Infra-free Variable Message Sign. Futhermore, for effective power management of operating Infra-free Variable Message Sign with limited power acquired through stand-alone PV system, new battery connection structure and dynamically variable power managements for the differently shown messages on Variable Message Sign are proposed. The proposed structure in this paper can be applied to not only power management for Infra-free Variable Message Sign but also power management for the various applications using parallel connection battery system.
참고문헌 (12)
- K. Chatterjee, "Driver response to variable message sign information in Lond", Transportation Research Part C: Emerging Technologies, 10(2), pp.149~169 (2002)
- 정헌영, "VMS(Variable Message Sign)를 통한 교통정보 제공이 운전자의 운행경로 전환에 미치는 영향 분석", 대한토목학회 논문집D, 31(2), pp.193~201 (2011), 대한토목학회
- 조덕기, "PV시스템 설치를 위한 경사면 태양광에너지 분석에 관한 연구", 한국태양에너지학회 논문집, 27(1), pp.11~18 (2007), 한국태양에너지학회
- 지식경제부, "태양광발전 용어 모음 2010년 최종판" (2010)
- 권오상, "독립형 태양광 조명 시스템의 설계 및 성능 평가 연구", 한국태양에너지학회 논문집, 24(4), pp.1~10 (2004), 한국태양에너지학회
- 국토해양부, "도로안전시설 설치 및 관리지침 제 4편-6도로전광표지", ~ (2009)
- Duryea, S., "A battery management system for stand-alone photovoltaic energy systems", Industry Applications Magazine, IEEE, 7(3), pp.67~72 (2001)
- P. Harnish, "The lead acid battery for solar applications", Renewable Energy World, pp.40~42 (1998)
- 기상청, "기상연보" (2007)
- 기상청, "기상연보" (2008)
- 기상청, "기상연보" (2009)
- 기상청, "기상연보" (2010)