통기구 유무와 옷 길이 차이에 따른 건설현장 작업복의 온열생리반응
Thermo-physiological Responses by Presence of Vents and Difference in Clothing Length for Construction Site Working Clothes
0
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
This study examined thermo-physiological responses according to the design change of construction site working clothes (control (C) working clothes; prototype (P) working clothes). We measured rectal temperature, skin temperature, micro-climate within the clothes and sweat rate. In the evaluation of physiological functionality, based on pattern improvement in working clothes, P working clothes showed significantly lower rectal temperatures, trunk and thigh skin temperatures than C working clothes. It is preferable that rectal temperature should be kept low during work that is not favorable to an increase in body temperature. P working clothes were more physiologically functional than C working clothes. In addition, P working clothes showed significantly lower temperatures in the trunk and thigh parts in a micro climate temperature. We could explain that the side seam zipper on the pants and the gusset on armpit parts create an air permeability effect of lowering the temperature of micro-climate. Aggressive ventilation through the slit of the garment is an important factor for the restoration of the physiological function of the worker at rest between work. Sweat rate showed a higher level in C working clothes than P working clothes. When working in a hot environment, workwear needs to be designed so that the worker is not exposed to thermal stress. Therefore, it was evaluated that the P work clothes used in this study alleviated the physiological burdens of heat.
Abstract
This study examined thermo-physiological responses according to the design change of construction site working clothes (control (C) working clothes; prototype (P) working clothes). We measured rectal temperature, skin temperature, micro-climate within the clothes and sweat rate. In the evaluation of physiological functionality, based on pattern improvement in working clothes, P working clothes showed significantly lower rectal temperatures, trunk and thigh skin temperatures than C working clothes. It is preferable that rectal temperature should be kept low during work that is not favorable to an increase in body temperature. P working clothes were more physiologically functional than C working clothes. In addition, P working clothes showed significantly lower temperatures in the trunk and thigh parts in a micro climate temperature. We could explain that the side seam zipper on the pants and the gusset on armpit parts create an air permeability effect of lowering the temperature of micro-climate. Aggressive ventilation through the slit of the garment is an important factor for the restoration of the physiological function of the worker at rest between work. Sweat rate showed a higher level in C working clothes than P working clothes. When working in a hot environment, workwear needs to be designed so that the worker is not exposed to thermal stress. Therefore, it was evaluated that the P work clothes used in this study alleviated the physiological burdens of heat.
참고문헌 (30)
- Adams, P. S., "A model for protective clothing effects on performance", International Journal of Clothing Science and Technology, 6(4), pp.6~14 (1994)[DOI]
- Amorim, F. T., "Is sweat rate during steady state exercise related to maximum oxygen uptake?", Journal of Thermal Biology, 31(6), pp.521~525 (2006)[DOI]
- Atmaca, I., "Predicting the effect of relative humidity on skin temperature and skin wettedness", Journal of Thermal Biology, 31(5), pp.442~452 (2006)[DOI]
- 배현숙, "산업현장의 작업환경 및 공정에 따른 작업복 착의실태-기계·자동차·조선업을 중심으로-", 한국의류학회지, 34(8), pp.1378~1391 (2010), 한국의류학회
- 배현숙, "조선업 작업장의 작업환경 및 산업용 보호복의 착의실태", 한국의류학회지, 36(5), pp.512~522 (2012), 한국의류학회[DOI]
- Che, J. D., "A study on the efficiency plan of safety management in small and medium construction spot", pp.1995
- Cho, J. W., "A study on causal effects of safety training and safetyawareness of construction industry workers affecting industrial incidents", pp.2009
- Choi, J. W., "Health hazardous substances in construction work in Korea", Korean Industrial Hygiene Association Journal, 10(1), pp.74~83 (2000)
- 최정화, "여름철건축현장 작업자의 작업복 착의 실태 및 작업 환경에 관한 연구", 한국의류학회지, 31(11), pp.1520~1529 (2007), 한국의류학회
- Cooper, J. M., "Kinesiology (3rd ed.)" (1972), Mosby
- Havenith, G., "Male and female upper body sweat distribution during running measured with technical absorbents", European Journal of Applied Physiology, 104(2), pp.245~255 (2008)[DOI]
- Inoue, Y., "Regional differences in the sweating responses of older and younger men", Journal of Applied Physiology, 71(6), pp.641~710 (1991)[DOI]
- Inoue, Y., "Seasonal variation in sweating responses of older and younger men", European Journal of Applied Physiology and Occupational Physiology, 70(1), pp.6~12 (1995)[DOI]
- Inukai, Y., "Effects of body posture on local sweating and sudomotor outflow as estimated using sweat expulsion", Autonomic Neuroscience: Basic and Clinical, 119(1), pp.48~55 (2005)[DOI]
- 주동엽, "장기간의 중강도 유산소성 운동이 심부온과 피부온에 미치는 영향", 한국 스포츠 리서치, 14(5), pp.77~90 (2003), 한국스포츠리서치
- 정지연, "건설현장 근로자의 안전의식과 안전교육 활성화 방안", 한국안전학회지, 28(1), pp.47~51 (2013), 한국안전학회
- Ke, Y., "An improved experimental method for local clothing ventilation measurement", International Journal of Industrial Ergonomics, 44(1), pp.75~81 (2014)[DOI]
- 김희은, "운동시 피부온의 변화에 대한 서모그래피 활용 분석", 한국의류산업학회지, 14(1), pp.130~135 (2012), 한국의류산업학회
- Kim, K. H., "Effect of uniform style and temperature change on physiological responses during submaximal exercise", Journal of the Korean Society Living Environment System, 6(2), pp.52~57 (1999)
- 김영관, "고구려의 청주지역 진출 시기", 선사와 고대, (25), pp.657~674 (2006), 한국고대학회[DOI]
- 이효정, "동작가동성이 향상된 작업복 하의 개발을 위한 시판 제품의 착용감 및 여유량 평가", 한국의류학회지, 41(4), pp.752~770 (2017), 한국의류학회
- Lee, M. K., "Wear sensation in accordance with clothing shapes of aerobic wear", Journal of the Korean Society Living Environment System, 4(4), pp.57~68 (1997)
- Nakayama, T., "Fall in skin temperature during exercise observed by thermograph", The Japanese Journal of Physiology, 31(5), pp.757~763 (1981)[DOI]
- Nam, S. N., "The heart rate and rectal temperature study of the different fabric sportswear during 60% <TEX>$VO_2$<", TEX> maximal exercise, 1994, pp.1(1), 23~29
- Nielsen, R., "Work clothing", International Journal of Industrial Ergonomics, 7, pp.77~85 (1991)[DOI]
- 박진아, "기계, 조선산업 용접 및 사상공정 근로자의 작업복 착의실태와 착용감 및 동작성능 연구", 패션 비즈니스, 15(2), pp.145~159 (2011), 한국패션비즈니스학회
- 박진아, "3차원 가상착의 시뮬레이션을 이용한 20~50대 연령별 남성 작업복 점퍼 패턴 설계 및 외관평가", 패션 비즈니스, 16(1), pp.103~120 (2012), 한국패션비즈니스학회
- 박혜원, "공단근로자의 작업복 디자인 실태 및 선호도 연구", 패션 비즈니스, 12(2), pp.134~152 (2008), 한국패션비즈니스학회
- Yang, J., "Integrating a human thermoregulatory modal with a clothing model to predict core and skin temperatures", Applied Ergonomics, 61, pp.168~177 (2017)[DOI]
- Yeon, S. M., "Effect of slit ventilation system in sportswear on physiological responses", pp.2004