심전도 모니터링 스마트 의류 디자인을 위한 바디매핑 기반 전극 위치 연구
A Study of Electrode Locations for Design of ECG Monitoring Smart Clothing based on Body Mapping
0
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
The increase in the need for a 24 hour monitoring of biological signals has been accompanied by an increasing interest in wearable systems that can register ECG at any time and place. ECG-monitoring clothing is a wearable system that records heart function continuously, but there have been difficulties in making accurate measurements due to motion artifacts. Although various factors may cause noise in measurements due to motion, the variations in the body surface and clothing during movements that cause eventual the shifting and displacement of the electrodes is particularly noteworthy. Therefore, this study used biomedical body mapping and a motion-capture system to measure and analyze the changes in the body surface and garment during movements. It was deduced that the area where the friction and separation between the garment and skin is the lowest would be the appropriate location to place the ECG electrodes. For this study, 5 male and 5 female in their 20s were selected as subjects, and through their selected body movements, the changes in the garment and skin were analyzed using the motion-capture system. As a result, the area below the chest circumference and the area below the shoulder blades were proposed as the optimal location of electrode for ECG monitoring.
Abstract
The increase in the need for a 24 hour monitoring of biological signals has been accompanied by an increasing interest in wearable systems that can register ECG at any time and place. ECG-monitoring clothing is a wearable system that records heart function continuously, but there have been difficulties in making accurate measurements due to motion artifacts. Although various factors may cause noise in measurements due to motion, the variations in the body surface and clothing during movements that cause eventual the shifting and displacement of the electrodes is particularly noteworthy. Therefore, this study used biomedical body mapping and a motion-capture system to measure and analyze the changes in the body surface and garment during movements. It was deduced that the area where the friction and separation between the garment and skin is the lowest would be the appropriate location to place the ECG electrodes. For this study, 5 male and 5 female in their 20s were selected as subjects, and through their selected body movements, the changes in the garment and skin were analyzed using the motion-capture system. As a result, the area below the chest circumference and the area below the shoulder blades were proposed as the optimal location of electrode for ECG monitoring.
참고문헌 (24)
- 조하경, "체표 변화에 기반한 심전도 모니터링 의류의 센싱 위치 연구", 한국의류산업학회지, 17(5), pp.844~853 (2015), 한국의류산업학회
- Hakyung Cho, "A Study on the Optimal Positions of ECG Electrodes in a Garment for the Design of ECG-Monitoring Clothing for Male", Journal of Medical Systems, 39(9), pp.1~14 (2015), Springer Nature[DOI]
- 조하경, "생체신호 측정을 위한 기능성 의류의 디자인 연구-심전도 센싱 의류를 중심으로-", 감성과학, 13(3), pp.467~474 (2010), 한국감성과학회
- Alper Cömert, "Effect of pressure and padding on motion artifact of textile electrodes", BioMedical Engineering OnLine, 12(1), pp.26~ (2013), Springer Nature[DOI]
- D.D. Finlay, "Optimal Electrocardiographic Lead Systems: Practical Scenarios in Smart Clothing and Wearable Health Systems", IEEE Transactions on Information Technology in Biomedicine, 12(4), pp.433~441 (2008), Institute of Electrical & Electronics Engineers (IEEE)[DOI]
- G. F. Fletcher, "Exercise Standards for Testing and Training: A Statement for Healthcare Professionals From the American Heart Association", Circulation, 104(14), pp.1694~1740 (2001), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Jang, S. E., "Effect of fabric elasticity and body movement on performance of electrocardiogram signal monitoring clothing", master, pp.2006
- 정연희, "휴대용 심전도 기기와 직물형 전극을 이용한 생체정보 측정용 밀착 의복 개발", 한국의류학회지, 34(1), pp.112~125 (2010), 한국의류학회[DOI]
- 정연희, "심전도 측정을 위한 밀착 의복 연구-패턴 축소 및 주관적 평가를 중심으로-", 한국의류학회지, 36(11), pp.1174~1185 (2012), 한국의류학회[DOI]
- 강다혜, "섬유전극을 기반으로 한 라이프스타일 모니터링용 ECG-센싱의류의 프로토타입 연구", 감성과학, 11(3), pp.419~426 (2008), 한국감성과학회
- Hye Ran Koo, "The Effect of Textile-Based Inductive Coil Sensor Positions for Heart Rate Monitoring", Journal of Medical Systems, 38(2), pp.1~12 (2014), Springer Nature[DOI]
- 구혜란, "비접촉식 심장활동 모니터링 기능 의복형 웨어러블 시스템의 모듈 효과 탐색", 한국의류학회지, 39(3), pp.369~378 (2015), 한국의류학회
- Koo, S. M., "A study on the design of re-modularized smart clothing for ECG-sensing", master, pp.2008
- Lee, Y. J., "Development of textile electrode measuring system for biopotential signals", master, pp.2010
- 이명호, "전기용량성 섬유 압력센서를 이용한 호흡측정 시스템", 전기학회 논문지 P권, 59(1), pp.58~63 (2010), 대한전기학회
- Mohindra, R., "Use of body-surface potential mapping and computer model simulations for optimal programming of cardiac resynchronization therapy devices", Proceeding of Conference of Computers in Cardiology, pp.69~72 (2007), IEEE
- "Motion capture system" (2011)[URL]
- Joseph P. Ornato, "80-Lead body map detects acute ST elevation myocardial infarction missed by standard 12-lead electrocardiography", Journal of the American College of Cardiology, 39(s2), pp.332~ (2002), Elsevier BV[DOI]
- Wesley H. Self, "Body surface mapping in the ED evaluation of the patient with chest pain: use of the 80-lead electrocardiogram system", The American Journal of Emergency Medicine, 24(1), pp.87~112 (2006), Elsevier BV[DOI]
- Sobieszczanska, M., "Appraisal of BSPM obtained from the limited lead system", The Anatolian Journal of Cardiology, 7, pp.11~13 (2007)
- H.‐Y. Song, "Textile electrodes of jacquard woven fabrics for biosignal measurement", Journal of the Textile Institute, 101(8), pp.758~770 (2010), Informa UK Limited[DOI]
- Tysler, M., "Noninvasive assessment of local myocardium repolarization changes using high resolution surface ECG mapping", Physiological Research, 56, pp.133~141 (2007)
- Watkins, S. M., "Clothing: The portable environment" (1984), Iowa State University Press
- 안유진, "전기방사에 이은 무전해 은도금을 통한 전도성 나노 섬유 웹의 제조와 ECG 측정용 건식 전극으로의 응용", 한국섬유공학회지, 49(1), pp.47~55 (2012), 한국섬유공학회[DOI]