본문 바로가기
KERD
논문KCI 등재

태양전지 모듈의 발전량 분석 장치 개발에 관한 연구

A Study on Development of Power Analysing Device for PV Module

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타공학

초록

This study was conducted to estimate the relative performance of modules with changed characteristics due to long term exposure to the outdoor environment, with a specially made test device for simultaneous measurement of real time power output from the photovoltaic array, taking into account the inclined panel, direct irradiation, power being generated, temperature as well as the optimal analysis timing. In terminology description, M is an abbreviation of module and Group A, Group B are 10 modules series connection (1∼10 of M), (11∼20 of M) for each of them respectively. The overall mean voltage difference of M-18 with the lowest power output and M-14 with the highest output is -2.13V and it was identifiable that voltage difference was more concentrated to Group B. In addition, in case of M-2 and M-7, M-8, when compared with M-14, the overall mean voltage difference was -0.92V, -1.56 and -0.91V respectively showing the more concentration to Group A. When the temperature of module went up by 1℃, the mean voltage was reduced by 0.35V. For current, Group A was lower than Group B by -0.022A and the ratio of each group was 49.68% and 50.32% respectively, presumably the module with deteriorated properties were more concentrated to Group A relatively. From the comparison of relations with the comprehensive accumulation, M-2, M-7, M-8, M-16 and M-18 were those with deterioration of performance to the worst, thereby requiring precision examination. In comparative efficiency, M-14 was the most excellent one as 12.19% while M-18 as 10.53% was identified that its efficiency was comparatively rapidly reduced

Abstract

This study was conducted to estimate the relative performance of modules with changed characteristics due to long term exposure to the outdoor environment, with a specially made test device for simultaneous measurement of real time power output from the photovoltaic array, taking into account the inclined panel, direct irradiation, power being generated, temperature as well as the optimal analysis timing. In terminology description, M is an abbreviation of module and Group A, Group B are 10 modules series connection (1∼10 of M), (11∼20 of M) for each of them respectively. The overall mean voltage difference of M-18 with the lowest power output and M-14 with the highest output is -2.13V and it was identifiable that voltage difference was more concentrated to Group B. In addition, in case of M-2 and M-7, M-8, when compared with M-14, the overall mean voltage difference was -0.92V, -1.56 and -0.91V respectively showing the more concentration to Group A. When the temperature of module went up by 1℃, the mean voltage was reduced by 0.35V. For current, Group A was lower than Group B by -0.022A and the ratio of each group was 49.68% and 50.32% respectively, presumably the module with deteriorated properties were more concentrated to Group A relatively. From the comparison of relations with the comprehensive accumulation, M-2, M-7, M-8, M-16 and M-18 were those with deterioration of performance to the worst, thereby requiring precision examination. In comparative efficiency, M-14 was the most excellent one as 12.19% while M-18 as 10.53% was identified that its efficiency was comparatively rapidly reduced

참고문헌 (5)

  1. 에너지관리공단 신.재생에너지센터 & 산업자원부, "신.재생에너지 RD&D전략 2030", ~ (2007)
  2. 강기환, "태양전지모듈의 노화현상에 따른 전기적 특성 고찰", 전기전자재료학회논문지, 17(12), pp.1289~1295 (2004), 한국전기전자재료학회
  3. LG산전주식회사 Hyperion LG태양광발전 시스템, "제품사양서", ~ (2002)
  4. PV시스템 구성요소 기기의 성능평가법 및 기술기준(안) 확립연구, , ~ (2004)
  5. 산업자원부, "태양광발전 용어집", ~ (2007)

관련 논문AI추천

이 간행물의 다른 논문 (19건)