It is a great interest to convert more energy in the heat source into the power and to improve the efficiency of power generating processes. Since the efficiency of power generating processes becomes poorer as the temperature of the source decreases, to use an ammonia-water mixture instead of water as working fluid is a possible way to improve the efficiency of the system. In this work performance of ammonia-water regenerative Rankine cycle is investigated for the purpose of extracting maximum power from low-temperature waste heat in the form of sensible energy. Special attention is paid to the effect of system parameters such as mass fraction of ammonia and turbine inlet pressure on the characteristics of system. Results show that the power output increases with the mass fraction of ammonia in the mixture, however workable range of the mass fraction becomes narrower as turbine inlet pressure increases and is able to reach 16.5 kW per unit mass flow rate of source air at 180 ℃.
Abstract
It is a great interest to convert more energy in the heat source into the power and to improve the efficiency of power generating processes. Since the efficiency of power generating processes becomes poorer as the temperature of the source decreases, to use an ammonia-water mixture instead of water as working fluid is a possible way to improve the efficiency of the system. In this work performance of ammonia-water regenerative Rankine cycle is investigated for the purpose of extracting maximum power from low-temperature waste heat in the form of sensible energy. Special attention is paid to the effect of system parameters such as mass fraction of ammonia and turbine inlet pressure on the characteristics of system. Results show that the power output increases with the mass fraction of ammonia in the mixture, however workable range of the mass fraction becomes narrower as turbine inlet pressure increases and is able to reach 16.5 kW per unit mass flow rate of source air at 180 ℃.
참고문헌 (10)
- Prisyazhniuk,V.A, "Alternativetrends indevelopmentofthermalpowerplant", Applied ThermalEngineering, 28, pp.190~194 (2008)
- Ibrahim,O.M, "Absorption powercycles", Energy, 21, pp.21~27 (1996)
- Ibrahim,O.M, "Designconsiderationfor ammonia-waterRankinecycle", Energy, 21, pp.835~841 (1996)
- Zamfirescu,C.,DincerI, "Thermodynamic analysisofanovelammonia-watertrilateral Rankinecycle", Thermo-chemicaActa, 477, pp.7~15 (2008)
- Roy,P, "Thermo-dynamicanalysis ofapowercycleusingalow-temperature sourceandabinary NH3-H2O mixture asworking fluid", Int.J.ThermalSci, 49, pp.48~58 (2010)
- Lolos,P.A, "A Kalina powercycledrivenbyrenewableenergy sources", Energy, 34, pp.457~464 (2009)
- Ogriseck,S, "IntegrationofKalinacycle in acombined heatand powerplant,a casestudy", AppliedTher.Eng, 29, pp.2843~2848 (2009)
- Yang,T, "ExtensionoftheWong-Sandlermixing rule to the three-parameter Patel-teja equationofstste:Applicationuptothe near-criticalregion", Chem.Eng.J, 67, pp.27~36 (1997)
- Xu,F, "Thermodynamic properties of ammonia-water mixtures for power-cycle application", Energy, 24, pp.525~536 (1999)
- SmithJ.M, "Introductiontochemicalengineering thermodynamics" (2005), McGraw-Hill