The purpose of study is to estimate heating, cooling load performance and economic efficiency in office building with applied the functional paint. this paint can reduced SHGC(Solar Heat Gain Coefficient) on the glazing surface by coating. In this study, estimated to compared with double glazing, low-e glazing, IP(Insulation Paint) and IPu(Insulation UV-Cut Paint) coating glazing. As a result of this study, 1)heating & cooling load Analysis, SHGC value and U-factor of double glazing is about 0.70 and 3.29(W/㎡K). low-E glazing is about 0.65 and 2.70(W/㎡K). Two-side it is about 0.27 and 3.25(W/㎡K). When compared to double glazing, annual heating & cooling load of low-E glazing, Two-side IPu and IP paint coating glazing is 3,012MWh(124kWh/㎡), 2,910MWh(120kWh/㎡), 2,867MWh(118.4kWh/㎡) and 2,867MWh(118.4kWh/㎡). It is reduced to 2.0%, 5.2%, 6.7%, and 6.7% respectively. 2)the estimation of economic efficiency, low-e glazing installed in office building can not recover the investment within a lifetime 40years. but IPu and IP paint, two-side coating in glazing, have a payback period of 13 years respectively.
Abstract
The purpose of study is to estimate heating, cooling load performance and economic efficiency in office building with applied the functional paint. this paint can reduced SHGC(Solar Heat Gain Coefficient) on the glazing surface by coating. In this study, estimated to compared with double glazing, low-e glazing, IP(Insulation Paint) and IPu(Insulation UV-Cut Paint) coating glazing. As a result of this study, 1)heating & cooling load Analysis, SHGC value and U-factor of double glazing is about 0.70 and 3.29(W/㎡K). low-E glazing is about 0.65 and 2.70(W/㎡K). Two-side it is about 0.27 and 3.25(W/㎡K). When compared to double glazing, annual heating & cooling load of low-E glazing, Two-side IPu and IP paint coating glazing is 3,012MWh(124kWh/㎡), 2,910MWh(120kWh/㎡), 2,867MWh(118.4kWh/㎡) and 2,867MWh(118.4kWh/㎡). It is reduced to 2.0%, 5.2%, 6.7%, and 6.7% respectively. 2)the estimation of economic efficiency, low-e glazing installed in office building can not recover the investment within a lifetime 40years. but IPu and IP paint, two-side coating in glazing, have a payback period of 13 years respectively.
참고문헌 (12)
- 장철용, "초단열 슈퍼 윈도우의 개발 방향", 한국생태환경건축학회 학술발표대회 논문집, 통권 : 7, pp.349~354 (2007)
- 한국에너지기술연구소, "첨단 일사조절 창호의 에너지 성능 평가 기술 개발" (1998), 과학기술부
- 임오연, "오피스 창호의 適定 및 最少 透過率 선정에 관한 연구", 대한건축학회논문집 계획계, 19(9), pp.155~161 (2003), 대한건축학회
- 김병수, "투명단열 축열벽 시스템을 적용한 주거용 건물의 냉난방에너지 성능분석", 대한건축학회논문집 계획계, 20(7), pp.283~290 (2004), 대한건축학회
- 윤종호, "대전지역 직달일사량 실측치 통계분석을 통한 국내일사량자료의 신뢰성 검증연구", 공기조화냉동공학회 대전 충청지부 강연회, ~ (1999)
- 김병수, "LED램프를 적용한 사무소 건물의 실내조명환경 및 에너지 성능분석", 대한건축학회논문집 계획계, 25(07), pp.329~336 (2009), 대한건축학회
- 김재웅, "사무소 건물에 적용된 에너지 세이버 도료 코팅 창호의 냉난방에너지 성능분석 및 경제성 평가", 대한건축학회논문집 계획계, 26(09), pp.209~216 (2010), 대한건축학회
- 한국건설기술연구원, "건축물의 LCA를 위한 원단위 작성 및 프로그램 개발 연구" (2004), 건설교통부
- 윤종호, "열관류율 민감도 분석에 따른 고단열 삼중창호 시스템의 단열성능평가 연구", 대한건축학회논문집 계획계, 23(10), pp.159~166 (2007), 대한건축학회
- 성욱주, "알루미늄 창호의 구성요소에 따른 단열성능예측", 대한건축학회 학술발표대회 논문집 (2006)
- 송수빈, "창호의 단열특성에 따른 공동주택의 에너지 절감효과 및 경제성 분석" (2009), 대한건축학회 춘계 우수졸업논문전수상논문 개요집
- Windows, "WINDOW 6.0", THERM 6.0ResearchVersionUser Manual,Lawrence Berkeley National Laboratory Berkeley,CA 94720 USA, LBNL-941, 2008