해수열원 스크류 히트펌프의 연간 난방운전 성능 모사
A Simulation Study on the Annual Heating Performance of the Seawater-Source Screw Heat Pump
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below -2.4℃, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance (COPH) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.
Abstract
In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below -2.4℃, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance (COPH) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.
참고문헌 (10)
- Han, S. K., "A design case study on sea and river water source heat pump", Proceedings of the SAREK Summer Annual Conference, 1212-1217 (2011)
- Kim, J. Y, "Experimental Study on the Cooling and Heating Operation Characteristics of a Sea Water Source Heat Pump", Proceedings of the SAREK Summer Annual Conference, pp.544~549 (2009)
- Park, J. Y, "Economical Evaluation for Cooling System using Seawater", Proceedings of the SAREK Summer Annual Conference, pp.861~866 (2010)
- Park, J. T, "Introduction and new trends in Unutilized energy", Magazine of the SAREK, 40, pp.13~20 (2011)
- 김환용, "냉·난방 부하계산을 위한 전국 17개 도시의 표준기상데이터 및 TAC 맵 작성", 대한건축학회논문집 계획계, 23(9), pp.197~204 (2007), 대한건축학회
- Kim, S. M, "A study of the actual analysis of using hot water heating in apartment housing with district heating system", Proceedings of the SAREK Summer Annual Conference, pp.892~898 (2007)
- "ANSI", AHRI Standard 540, 2004
- Stoecker, W. F, "Industrial Refrigeration Handbook" (1998), McGraw-Hill
- AHRI, "Standard for Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment", ~ (2009)