실내 차양장치 결합형 창호의 태양열 취득률 평가에 대한 실험적 연구

A Experiment Study on Performance Evaluation of Solar Heat Gain Coefficient in Glazing with Shading Devices

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류기타공학

초록

The determination of the solar and thermal performance of fenestration is required for the evaluation of fenestration energy performance, estimating building load. Presently, there exist several methods for determining the thermal transmission(U-value) and solar heat gain coefficient(SHGC) of fenestration system. These method are commonly grouped under calculation or experimental methods. While U-value testing and calculation methods have been long established, SHGC has been evaluated only by the method of calculation under the lack of any established testing method. However, it is difficult to assess the exact SHGC for various types of fenestration with sun-shading or other solar control systems. The purpose of this study was to evaluate the effect of interior venetian blind and roll screen on the SHGC of glazing system. SHGC has been evaluated by the KS L 9107 test method and exiting calculation method for precise comparison of the energy performances of various shading devices. In this research, the test sample consists of three different types of double glazing unit with venetian blind and roll screen. Slat angles of venetian blind were changed to -45˚, 0˚, and –45˚. For the roll screen, measurements were taken with the roll screen in the closed position. In results, the venetian blind reduced SHGC by 21.2~28.4% at 45˚, when compared to the double glazing unit. The roll screen reduced SHGC by 34.4~41.7% at closed. The differences between the measured and calculated SHGC were found to range between 0.001(0.2%) and 0.047(11.1%) for all test cases. For the cases of venetian blind –45˚, 0˚and 45˚, the deviation ratio were 3.6~9.8%, 1.1~2.6%, 4.2~11.1%, respectively. For the case of roll screen, the deviation ratio were 4.1~5.7%.

Abstract

The determination of the solar and thermal performance of fenestration is required for the evaluation of fenestration energy performance, estimating building load. Presently, there exist several methods for determining the thermal transmission(U-value) and solar heat gain coefficient(SHGC) of fenestration system. These method are commonly grouped under calculation or experimental methods. While U-value testing and calculation methods have been long established, SHGC has been evaluated only by the method of calculation under the lack of any established testing method. However, it is difficult to assess the exact SHGC for various types of fenestration with sun-shading or other solar control systems. The purpose of this study was to evaluate the effect of interior venetian blind and roll screen on the SHGC of glazing system. SHGC has been evaluated by the KS L 9107 test method and exiting calculation method for precise comparison of the energy performances of various shading devices. In this research, the test sample consists of three different types of double glazing unit with venetian blind and roll screen. Slat angles of venetian blind were changed to -45˚, 0˚, and –45˚. For the roll screen, measurements were taken with the roll screen in the closed position. In results, the venetian blind reduced SHGC by 21.2~28.4% at 45˚, when compared to the double glazing unit. The roll screen reduced SHGC by 34.4~41.7% at closed. The differences between the measured and calculated SHGC were found to range between 0.001(0.2%) and 0.047(11.1%) for all test cases. For the cases of venetian blind –45˚, 0˚and 45˚, the deviation ratio were 3.6~9.8%, 1.1~2.6%, 4.2~11.1%, respectively. For the case of roll screen, the deviation ratio were 4.1~5.7%.

참고문헌 (14)

  1. Energy consumption survey Report, "Ministry of Trade, Industry and Energy", ~ (2011)
  2. M. R. Collins, "Calorimetric Measurement of the Inward-Flowing Fraction of Absorbed Solar Radiation in Venetian Blind", ASHRAE Transactions: Conference proceeding by ASHRAE, pp.1022~1030 (1999)
  3. Prospect of Electricpower, Consumption and supply in summer, "Ministry of Trade, Industry and Energy", ~ (2013)
  4. 박률, "주택 창의 SHGC가 에너지소비에 미치는 영향에 관한 연구", 설비공학 논문집, 22(4), pp.189~196 (2010), 대한설비공학회
  5. T. R. Nielsen, "Energy performance of glazing and windows", Solar energy, 69(6), pp.137~143 (2000)
  6. Fangzhi Chen, "Solar heat gain coefficient measurement of semi-transparent photovoltaic modules with indoor calorimetric hot box and solar simulator", Energy and Buildings, 53, pp.74~84 (2012)
  7. Deivis L. Marinoski, "Development of a calorimeter for determination of the solar factor of architectural glass", Building and Environment, 47, pp.232~242 (2012)
  8. Klems J. H., "A New method for Predicting the Solar Heat Gain of Complex Fenestration System", ASHRAE Transaction, 100, pp.303~312 (1993)
  9. 임재한, "NFRC 201 실험방법에 의한 내부 차양장치가 적용된 창호의 일사획득계수 평가", 한국태양에너지학회 논문집, 30(3), pp.47~54 (2010), 한국태양에너지학회
  10. 임재한, "실내외 베네시안 블라인드가 결합된 창호시스템의 일사획득계수에 미치는 영향", 한국생활환경학회지, 17(5), pp.529~538 (2010), 한국생활환경학회
  11. "KS L 9107, Testing method for the determination of solar heat gain coefficient of fenestration product using solar simulator", ~ (2014)
  12. "KS C IEC60904-9, Photovoltaic devices-Part 9 : Solar simulator performance requirements", ~ (2010)
  13. "KS F 2278, Test method of thermal resistance for windows and doors", ~ (2008)
  14. "ISO 15099, Thermal performance of windows, doors and shading devices-Detailed calculations", ~ (2003)