This paper is focused on the effect of indoor temperature rise according to the use of windows and blinds in double skin facade in summer. For the experiment, we set up the mock-up of double skin facede and measuring temperature and solar radiation. Total 7 cases were used for measuring solar transmittance and indoor temperature rise. When the venetian blind was not installed, solar transmittance was 44.5%, and solar transmittance for the case that installed the venetian blind (angle 0) was 22.5%. Cases that opened inner and outdoor windows for ventilation showed lower indoor temperature rise than cases with closed windows. In addition, Case5 (opened inner and outdoor windows with the venetian blind (angle 0) to reduce solar transmittance) indicated lower indoor temperature rise than Case3 (opened inner and outdoor windows). Consequently, Case5 which uses inner and outdoor window for ventilation and venetian blind to reduce solar transmittance is the most effective way to reduce indoor temperature rise among all cases tested in this research.

Abstract

This paper is focused on the effect of indoor temperature rise according to the use of windows and blinds in double skin facade in summer. For the experiment, we set up the mock-up of double skin facede and measuring temperature and solar radiation. Total 7 cases were used for measuring solar transmittance and indoor temperature rise. When the venetian blind was not installed, solar transmittance was 44.5%, and solar transmittance for the case that installed the venetian blind (angle 0) was 22.5%. Cases that opened inner and outdoor windows for ventilation showed lower indoor temperature rise than cases with closed windows. In addition, Case5 (opened inner and outdoor windows with the venetian blind (angle 0) to reduce solar transmittance) indicated lower indoor temperature rise than Case3 (opened inner and outdoor windows). Consequently, Case5 which uses inner and outdoor window for ventilation and venetian blind to reduce solar transmittance is the most effective way to reduce indoor temperature rise among all cases tested in this research

참고문헌 (5)

  1. 김강수, "건물개구부의 에너지 성능 평가에 관한연구", pp.45~ (1998), 한국건설기술연구원
  2. 박주현, "소규모 사무공간 외피 존의 에너지 절감을 위한 투과체 및 차양계획에 관한 연구", 대한건축학회논문집 계획계, 25(08), pp.321~328 (2009), 대한건축학회
  3. AliFallahi, "Energyperformanceassessment ofdouble-skinfacadewiththermalmass", EnergyandBuilding, 42(9) (2010)
  4. 엄정원, "이중외피 시스템의 에너지성능평가를 위한 하절기 열환경 및 자연환기 분석", 한국태양에너지학회 논문집, 22(4), pp.68~76 (2002), 한국태양에너지학회
  5. 김덕우, "유닛 타입 이중외피 시스템의 형상 및 구성요소에 따른 에너지 성능 평가", 대한건축학회논문집 계획계, 26(01), pp.379~387 (2010), 대한건축학회