본문 바로가기
KERD
논문KCI 등재

창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석

A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타공학

초록

This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 m2. The analysis results were as follows. First, as the window glass’s thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m X 1m window’s thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m X 2 m window. Secondly, in the comparison of performance for increasing area with 2 m X 2 m and 3 m X 3 m windows, the 3 m X 3 m window’s thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model’s total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

Abstract

This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 m2. The analysis results were as follows. First, as the window glass’s thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m X 1m window’s thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m X 2 m window. Secondly, in the comparison of performance for increasing area with 2 m X 2 m and 3 m X 3 m windows, the 3 m X 3 m window’s thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model’s total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

참고문헌 (10)

  1. Ministry of Land, Infrastructure and Transport (MOLIT), "Act on Supporting Green Building construction, Korea National Law, No. 16418", ~ (2019)
  2. Ministry of Land, Infrastructure and Transport (MOLIT), "Building Energy Saving Design Criteria, Ministry of Land, Infrastructure and Transport Notice, No. 2017-881", ~ (2017)
  3. Korean Agency for Technology and Standard, "Standard test method for thermal resistance for windows and doors(KS F 2278)", Korean Industrial Standards, ~ (2017)
  4. Korean Agency for Technology and Standard, "Testing method for the determination of solar heat gain coefficient of fenestration product using solar simulator (KS L 9107)", Korean Industrial Standards, ~ (2014)
  5. 장향인, "창호 크기와 성능이 열관류율에 미치는 영향에 대한 연구", 한국건축친환경설비학회 논문집, 8(1), pp.14~20 (2014), 한국건축친환경설비학회
  6. 문정현, "창호 크기 변화 시 고정창 열관류율 변화에 관한 연구", 한국건축친환경설비학회 논문집, 13(1), pp.70~80 (2019), 한국건축친환경설비학회[DOI]
  7. Mitchell, R., "THERM 7", WINDOW 7 NFRC Simulation Manual, 2017
  8. Lawrence Berkeley National Laboratory, "Energy Plus Manual, Energy Plus™Version 9.2.0 Documentation", ~ (2019)
  9. 박소희, "공동주택의 재실, 조명, 기타 발열기기 이용 스케줄 작성에 관한 연구", 대한건축학회논문집, 30(9), pp.57~64 (2014), 대한건축학회[DOI]
  10. 윤재옥, "신축 공동주택에서 감압법을 이용한 기밀성능 실측 연구", KIEAE Journal, 13(3), pp.27~32 (2013), 한국생태환경건축학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (4건)