본문 바로가기
KERD
논문KCI 등재

태양열 축열조가 없는 변유량 제어 방식의 지역난방용 태양열시스템 실증시험연구

The Development of the Climatic Design Tool for Energy Efficient Building Design

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류기타공학

초록

In this study, the design of the solar heating system for district heating as well as it’s operating characteristics and the performance analysis was carried out. This solar district heating system was composed of two different types of solar collector circuit, flat plate and vacuum tube solar collector, in a system. This system supply constant temperature of hot water without solar buffer tank. For this, the proportional(variable flow rate) control was used. The experimental facility for this study was used the Bundang district solar heating system which was installed in the end of 2006. The operating characteristics and behaviour of each collector circuits are investigated especially for the system design and control. The yearly solar thermal efficiency is 47.5% on the basis of aperture area and 39.8% on the basis of gross area of collector. As a result this solar heating system without solar buffer tank and with proportional controller was testified a very effective and simplified system for district heating. It varied especially depend on the weather condition like as solar radiation and ambient temperature.

Abstract

In this study, the design of the solar heating system for district heating as well as it’s operating characteristics and the performance analysis was carried out. This solar district heating system was composed of two different types of solar collector circuit, flat plate and vacuum tube solar collector, in a system. This system supply constant temperature of hot water without solar buffer tank. For this, the proportional(variable flow rate) control was used. The experimental facility for this study was used the Bundang district solar heating system which was installed in the end of 2006. The operating characteristics and behaviour of each collector circuits are investigated especially for the system design and control. The yearly solar thermal efficiency is 47.5% on the basis of aperture area and 39.8% on the basis of gross area of collector. As a result this solar heating system without solar buffer tank and with proportional controller was testified a very effective and simplified system for district heating. It varied especially depend on the weather condition like as solar radiation and ambient temperature.

참고문헌 (4)

  1. 백남춘, "대규모 태양열 지역냉난방 및 급탕시스템 개발 및 적용연구" (2007)
  2. 백남춘, "태양열시스템 최적화와 신뢰성 향상을 위한 설계 및 성능기준 개발과 실증시험 연구" (2002)
  3. 신우철, "설비형 태양열시스템 설계분석 프로그램 개발", 한국태양에너지학회 논문집, 23(4), pp.11~20 (2003), 한국태양에너지학회
  4. "TRNSYS 14.2 Reference manual", University of Wisconsin -Maidison (1996)