The advanced counties effort to the supplement of the zero energy buildings for the global building energy saving. In the middle of the development of passive technology, the government has to effort to the energy saving of buildings by enhanced performance of the window thermal insulation. By the method of enhanced performance of window thermal insulation, the use of vacuum double glazing saves the energy consumption in building. This glazing has low U-value(heat transmission coefficient) than normal double glazing. The vacuum glazing enhanced thermal insulation performance by vacuum space of between the glass and glass. For this vacuum glazing, pillar maintain the space between glass and glass. But this structure cause the raising the heat transmission coefficient in pillar approaching glass. This study confirmed the U-value by the test method of thermal resistance for windows and doors. Also this study confirmed the variation of heat transmission coefficient by the structure of vacuum glazing. And this study measured the surface temperature of the vacuum glazing about pillar approaching glass and vacuum space in cool chamber and hot box. That result, this study confirmed U-value of 0.422 W/㎡·K of vacuum glazing. Also this study confirmed U-value of 0.300∼0.422 W/㎡·K by various the structure of vacuum glazing. And this study confirmed the heat flow in pillar approaching glass.

Abstract

The advanced counties effort to the supplement of the zero energy buildings for the global building energy saving. In the middle of the development of passive technology, the government has to effort to the energy saving of buildings by enhanced performance of the window thermal insulation. By the method of enhanced performance of window thermal insulation, the use of vacuum double glazing saves the energy consumption in building. This glazing has low U-value(heat transmission coefficient) than normal double glazing. The vacuum glazing enhanced thermal insulation performance by vacuum space of between the glass and glass. For this vacuum glazing, pillar maintain the space between glass and glass. But this structure cause the raising the heat transmission coefficient in pillar approaching glass. This study confirmed the U-value by the test method of thermal resistance for windows and doors. Also this study confirmed the variation of heat transmission coefficient by the structure of vacuum glazing. And this study measured the surface temperature of the vacuum glazing about pillar approaching glass and vacuum space in cool chamber and hot box. That result, this study confirmed U-value of 0.422 W/㎡·K of vacuum glazing. Also this study confirmed U-value of 0.300∼0.422 W/㎡·K by various the structure of vacuum glazing. And this study confirmed the heat flow in pillar approaching glass.

참고문헌 (5)

  1. Korea Institute of Energy Technology Evaluation and Planing, "Green Energy strategy road map Energy saving Building", ~ (2011)
  2. 황일선, "진공유리의 설계 조건에 따른 단열 성능 연구", 한국생산제조시스템학회지, 21(4), pp.582~587 (2012), 한국생산제조시스템학회[DOI]
  3. 송태호, "단열 진공유리의 제작 및 열전달계수 측정에 관한 실험적 연구", 대한기계학회논문집 B, 30(8), pp.772~779 (2006), 대한기계학회
  4. Kim. J. K., "The strength Simulation and Test of Glass According to Array Separation of Pillars to Maintain Vacuum Gap", 2013 Air-conditioning and Refrigerating Engineers of Korea winter conference, pp.133~135 (2013)
  5. "KS F 2278, Standard test method for thermal resistance for windows and doors", ~ (2014)