PV모듈의 음영 상태 및 바이패스 다이오드 단락 고장특성 분석
The Characteristics of PV module under the Partial Shading Condition and with a Failure of Bypass Diode with Short
2
조회
0
다운로드
8
인용
0
참고문헌
키워드
초록
A bypass diode is connected in parallel to solar cells with opposite polarity. The advantage of using the bypass diode is circumvented a destructive efforts of hot-spot heating in the photovoltaic(PV) module. In addition, it is possible to reduce a energy loss under the partial shading on the PV module. This paper presents a characteristic of photovoltaic module under partial shading condition and with defective bypass diode by using the experimental data. The results of field testing for each photovoltaic modules, when photovoltaic system which is connected power grid is operating, the inner junction-box temperature of shading photovoltaic module is high 5℃ because of difference of flowing current through into bypass diode. And incase of not operating photovoltaic system, the inner junction-box temperature of module with defective bypass diode is greatly higher than partial shading PV module.
Abstract
A bypass diode is connected in parallel to solar cells with opposite polarity. The advantage of using the bypass diode is circumvented a destructive efforts of hot-spot heating in the photovoltaic(PV) module. In addition, it is possible to reduce a energy loss under the partial shading on the PV module. This paper presents a characteristic of photovoltaic module under partial shading condition and with defective bypass diode by using the experimental data. The results of field testing for each photovoltaic modules, when photovoltaic system which is connected power grid is operating, the inner junction-box temperature of shading photovoltaic module is high 5℃ because of difference of flowing current through into bypass diode. And incase of not operating photovoltaic system, the inner junction-box temperature of module with defective bypass diode is greatly higher than partial shading PV module.
참고문헌 (10)
- 소정훈, "PV시스템 최적화를 위한 손실요인 분석", 전력전자학회 논문지, 11(1), pp.22~28 (2006), 전력전자학회
- Kang Gi-Hwan, "The type of complaints and failure of photovoltaic system", Bulletin of the Korea Photovoltaic Society, 1(1) (2015)
- Ji Yang-Geun, "The Characteristic of the Performance of the Bypass Diode with Composition Change of the String in Si-PV Module", Journal of Korea Institute of Electronics Engineers, 50(7), pp.985~996 (2014)
- Chae Myoung-Suk, "A Study on Bypass Characteristics for Photovoltaic Module", 전력전자학회, 전력전자학술대회논문집, pp.79~80 (2014)
- 소정훈, "계통연계형 태양광발전시스템의 손실 산출방법", 한국태양에너지학회 논문집, 33(5), pp.18~23 (2013), 한국태양에너지학회
- 소정훈, "3kW급 계통연계형 태양광발전시스템의 성능특성 비교분석에 관한 연구", 한국태양에너지학회 논문집, 24(2), pp.9~15 (2004), 한국태양에너지학회
- Pearsall NM, "Progress on the Modernisation of the European PV System Monitoring Guidelines", European Photovoltaic Solar Energy Conference, pp.3208~3216 (2008)
- Lijun Gao, "Parallel-Connected Solar PV System to Address Partial and Rapidly Fluctuating Shadow Conditions", Journal of the Institute of Electrical and Electronics Engineers, 56(5) (2009)
- Kim Seung-Tae, "The Electrical Characteristics of Shading Effect in Photovoltaic Module", Journal of the Korean Solar Energy Society, pp.257~262 (2008)
- 신우균, "PV 모듈 내 바이패스 다이오드 손상에 의한 열적 전기적 특성 변화 분석", 한국태양에너지학회 논문집, 35(4), pp.67~76 (2015), 한국태양에너지학회