열적으로 활성화된 광선반 시스템의 냉방 효과 시뮬레이션 연구
Simulation Study on Cooling Effect of Thermally Activated Light Shelf (TALS) System
1
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
A light shelf is commonly used to mitigate glare discomfort and overheating by preventing solar radiation from penetrating the indoor space. If the light shelf can be thermally activated, it can also be used for space cooling, particularly for the perimeter zone in buildings. In this study, a thermally activated light shelf (TALS) system was proposed, where the light shelf was integrated with a radiant cooling panel system. To examine the applicability of the TALS system, heat transfer simulations were conducted using the Physibel software. Based on the simulation results, the layer of TALS was determined to maximize cooling capacity at the lower panel surface while minimizing the lower surface temperature. Transient simulations were also conducted to evaluate the cooling effect of the TALS system during the summer season. Simulation results showed that the TALS system could reduce the average perimeter and interior zone temperature by 2.23°C and 2.19°C, respectively. With the TALS system, the maximum temperature was reduced by 3.2°C in both the perimeter and interior zones. It was found that the TALS system could effectively reduce the room air temperature, which could lead to cooling energy savings. The impact of the TALS system on cooling energy consumption needs to be investigated in future studies.
Abstract
A light shelf is commonly used to mitigate glare discomfort and overheating by preventing solar radiation from penetrating the indoor space. If the light shelf can be thermally activated, it can also be used for space cooling, particularly for the perimeter zone in buildings. In this study, a thermally activated light shelf (TALS) system was proposed, where the light shelf was integrated with a radiant cooling panel system. To examine the applicability of the TALS system, heat transfer simulations were conducted using the Physibel software. Based on the simulation results, the layer of TALS was determined to maximize cooling capacity at the lower panel surface while minimizing the lower surface temperature. Transient simulations were also conducted to evaluate the cooling effect of the TALS system during the summer season. Simulation results showed that the TALS system could reduce the average perimeter and interior zone temperature by 2.23°C and 2.19°C, respectively. With the TALS system, the maximum temperature was reduced by 3.2°C in both the perimeter and interior zones. It was found that the TALS system could effectively reduce the room air temperature, which could lead to cooling energy savings. The impact of the TALS system on cooling energy consumption needs to be investigated in future studies.
참고문헌 (15)
- Lim, Y. W., "Dynamic Internal Light Shelf for Tropical Daylighting in High-rise Office Buildings", Building and Environment, 106, pp.155~166 (2016)
- Ebrahimi-Moghadam, A., "Sensitivity Analysis and Multi-objective Optimization of Energy Consumption and Thermal Comfort by Using Interior Light Shelves in Residential Buildings", Renewable Energy, 159, pp.736~755 (2020)
- Mangkuto, R. A., "Optimisation of Daylight Admission Based on Modifications of Light Shelf Design Parameters", Journal of Building Engineering, 18, pp.195~209 (2018)
- 이행우, "실내공간 깊이와 광선반 규격 변화에 의한 광선반 성능평가 시뮬레이션 연구", 대한건축학회논문집, 29(03), pp.335~344 (2013), 대한건축학회
- 김정민, "PV 부착 광선반의 채광성능 및 에너지 저감 기초 연구", 설비공학 논문집, 30(8), pp.376~387 (2018), 대한설비공학회[DOI]
- 장민우, "광선반 채광성능 개선을 위한 프리즘시트 적용 방안 연구", 설비공학 논문집, 30(9), pp.401~412 (2018), 대한설비공학회[DOI]
- 전강민, "빛환경 및 냉난방환경 기반 광선반 성능평가 연구", KIEAE Journal, 16(5), pp.47~55 (2016), 한국생태환경건축학회
- Bahdad, A. A. S., "Sensitivity Analysis Linked to Multi-objective Optimization for Adjustments of Light-shelves Design Parameters in Response to Visual Comfort and Thermal Energy Performance", Journal of Building Engineering, 44, pp.102996~ (2021)
- Chaloeytoy, K., "Comparing the Occupants’ Comfort between Perimeter Zone and Interior Zone in Asian Office", IOP Conference Series: Earth and Environmental Science, 294(1), pp.012075~ (2019)
- Schiavon, S., "Influence of Raised Floor on Zone Design Cooling Load in Commercial Buildings", Energy and Buildings, 42(8), pp.1182~1191 (2010)
- Ning, B., "Cooling Capacity Improvement for a Radiant Ceiling Panel with Uniform Surface Temperature Distribution", Building and Environment, 102, pp.64~72 (2016)
- Shin, M. S., "Design of Radiant Floor Heating Panel in View of Floor Surface Temperatures", Building and Environment, 92, pp.559~577 (2015)
- Babiak, J., "Low Temperature Heating and High Temperature Cooling: REHVA Guidebook, No. 7" (2007)
- Climate Data of Seoul, "KSES", ~ (2015)
- 정기범, "일사차단용 설비를 이용한 냉방 에너지 절약 방안", 한국태양에너지학회 논문집, 30(3), pp.108~115 (2010), 한국태양에너지학회