실측 데이터 기반 교육시설 건물의 Grey-box 모델 개발 및 MPC 시뮬레이션
Grey-box Model Develop and MPC Simulation of Campus Office Zone Based on Actual Measurement
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This study aimed to develop a grey-box building model in a zone of a high-rise building on a university campus and to simulate model-based predictive control. Grey-box modeling was performed using various indoor and external environment data measured within a single-person office space on a high floor. The residence schedule was indirectly calculated using values such as indoor CO2 concentration and plug power. In addition, the catalog rating value was applied as the cooling energy value of the indoor 4-ways air conditioner as this could not be measured. Measurements were performed for approximately 4-weeks, and operating data of the heat pump and non-operating (i.e., free-floating) data were obtained according to the weekday and weekend schedules. The grey-box model was parameterized using the linear time-invariant and linear time-variant models. Both models showed good predictive performance with a root mean square error of less than 1°C in the 2-week estimation and 2-week validation results. Based on these results, an MPC simulation was performed. MPC simulation in a single zone were conducted for various electricity cost structures to derive quantitative electricity cost savings compared to those of feedback control.
Abstract
This study aimed to develop a grey-box building model in a zone of a high-rise building on a university campus and to simulate model-based predictive control. Grey-box modeling was performed using various indoor and external environment data measured within a single-person office space on a high floor. The residence schedule was indirectly calculated using values such as indoor CO2 concentration and plug power. In addition, the catalog rating value was applied as the cooling energy value of the indoor 4-ways air conditioner as this could not be measured. Measurements were performed for approximately 4-weeks, and operating data of the heat pump and non-operating (i.e., free-floating) data were obtained according to the weekday and weekend schedules. The grey-box model was parameterized using the linear time-invariant and linear time-variant models. Both models showed good predictive performance with a root mean square error of less than 1°C in the 2-week estimation and 2-week validation results. Based on these results, an MPC simulation was performed. MPC simulation in a single zone were conducted for various electricity cost structures to derive quantitative electricity cost savings compared to those of feedback control.
참고문헌 (13)
- "News" (2021)[URL]
- "Terms"[URL]
- 조진균, "병원건물에너지 절감을 위한 진단", 평가방법 체계화 및 에너지관리 프로세스 개발, 2018, pp.30(8), 388~399[DOI]
- 양수현, "에너지절감기술 도입 효과 분석을 위한 건물에너지소비량 예측 및 평가 도구 개발", 한국건축친환경설비학회 논문집, 13(4), pp.270~280 (2019), 한국건축친환경설비학회[DOI]
- Joe, J., "Theoretical Consideration and Applicability of Model-based Predictive Control (MPC) Research using Grey-box", Korea Green Building Council, 22(2), pp.7~13 (2021)
- Yanfei Li, "Grey-box modeling and application for building energy simulations - A critical review", Renewable and Sustainable Energy Reviews, 146, pp.111174~ (2021), Elsevier BV[DOI]
- 박세미, "기계학습 적용을 위한 건물에너지 데이터의 생성 방법론 개발", 한국태양에너지학회 논문집, 41(4), pp.107~114 (2021), 한국태양에너지학회[DOI]
- O.M. Brastein, "Parameter estimation for grey-box models of building thermal behaviour", Energy and Buildings, 169, pp.58~68 (2018), Elsevier BV[DOI]
- Jaewan Joe, "A model predictive control strategy to optimize the performance of radiant floor heating and cooling systems in office buildings", Applied Energy, 245, pp.65~77 (2019), Elsevier BV[DOI]
- "Input Output Reference" (2022)[URL]
- M. Mirsadeghi, "Review of external convective heat transfer coefficient models in building energy simulation programs: Implementation and uncertainty", Applied Thermal Engineering, 56(1-2), pp.134~151 (2013), Elsevier BV[DOI]
- "Inha Introduction"[URL]
- "Automated Synoptic Observing System"[URL]