본문 바로가기
KERD
논문KCI 등재

3차원 동적 열전달해석 방법론을 이용한 BIPV 시스템의 열전달특성 및 발전성능 분석

Analysis of Heat Transfer Characteristics and Electrical Performance of BIPV Systems Using a 3D Thermal Analysis

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타공학

초록

A building-integrated photovoltaic (BIPV) system integrates solar modules into the exterior structure of buildings. Particularly, in countries with limited land area and many high-rise buildings, such as Korea, BIPV is a favorable technology for securing building energy production capacity. Herein, a three-dimensional dynamic thermal analysis was conducted on the most widely applied curtain wall-integrated and spandrel-integrated BIPV systems in Korea. The analysis involved deriving the rear temperature of the module to examine the power-generation efficiency and output under actual operating conditions. The power generation efficiency of the curtain wall-integrated BIPV system decreased by a maximum of 4.35% compared with that of the individual modules, whereas it decreased by a maximum of 5.10% for the spandrel-integrated system.

Abstract

A building-integrated photovoltaic (BIPV) system integrates solar modules into the exterior structure of buildings. Particularly, in countries with limited land area and many high-rise buildings, such as Korea, BIPV is a favorable technology for securing building energy production capacity. Herein, a three-dimensional dynamic thermal analysis was conducted on the most widely applied curtain wall-integrated and spandrel-integrated BIPV systems in Korea. The analysis involved deriving the rear temperature of the module to examine the power-generation efficiency and output under actual operating conditions. The power generation efficiency of the curtain wall-integrated BIPV system decreased by a maximum of 4.35% compared with that of the individual modules, whereas it decreased by a maximum of 5.10% for the spandrel-integrated system.

참고문헌 (9)

  1. Jhumka, H., "Assessing Heat Transfer Characteristics of Building Envelope Deployed BIPV and Resultant Building Energy Consumption in a Tropical Climate", Energy and Buildings, 298, pp.113540~ (2023)
  2. Boafo, F. E., "Study on Thermal Characteristics and Electrical Performance of a Hybrid Building Integrated Photovoltaic(BIPV)System Combined with Vacuum Insulation Panel(VIP)", Energy and Buildings, 277(23), pp.112574~ (2022)
  3. Kaplanis, S., "PV Temperature and Performance Prediction in Free-Standing, BIPV and BAPV Incorporating the Effect of Temperature and Inclination on the Heat Transfer Coefficients and the Impact of Wind", Efficiency and Ageing, Renewable Energy, 181, pp.235~249 (2022)
  4. Yu, G., "A Review on Developments and Researches of Building Integrated Photovoltaic(BIPV)Windows and Shading Blinds", Renewable and Sustainable Energy Reviews, 149, pp.111355~ (2021)
  5. "EN ISO 6946:2017, Building Components and Building Elements-Thermal Resistance and Thermal Transmittance-Calculation Methods", International Organization for Standardization, ~ (2022)
  6. "EN ISO 10211:2017, Thermal Bridges in Building Construction-Heat Flows and Surface Temperatures-Detailed Calculations", International Organization for Standardization, ~ (2022)
  7. Kim, G. J., "BIPV System Performance Test Evaluation Technology", The Korean Institute of Electrical Engineers, 63(3), pp.37~42 (2014)
  8. Min istry of Land, nIfrastructure and Tarnsport, "Standard for Energy Conservation ni Buidling", ~ (2023)
  9. Str opnik, R., "Increasing the Efficiency of PV Panel with the Use of PCM", Renewable Energy, 97, pp.671~679 (2016)[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (11건)