Li-ion batteries are mainly used in energy storage system (ESS) systems, but they have the issue of significant battery fire incidents. Many thermal management technologies to respond to the heat load of batteries using phase change material (PCM) have been studied. We studied the thermal and power consumption properties depending on the charge/discharge and outside temperature of the ESS battery room through field survey data and an experiment. First, data for the heat pump power consumption and various temperature points of an ESS system were measured daily in the commercial operation of a 250 kWh PV-ESS for a year. Correlation analysis of the power consumption of a heat pump cooling and heating operation to maintain the temperature in the ESS battery room shows that the outside air temperature is the major factor. Furthermore, we conducted an experiment to determine the properties of temperature and power consumption by season at a fabricated ESS battery room with a 250 kWh Li-ion battery including 23°C PCM modules. PCM supports cooling and heating to maintain the room temperature as the heat pump operation cycles on and off. The ESS with applied PCM shows a reduction of heat pump power consumption and improved thermal management according to the load of the heating battery for charging/discharging and the day/night outside air temperature. The power consumptions for heating and cooling due to the battery heat load with a charging and discharging capacity of 150 kWh for each season condition for the only-heat-pump and PCM-applied system operations are 5.6 kWh and 0.88 kWh for changing seasons, 16.5 kWh and 15.8 kWh for summer, and 14.3 kWh and 12.2 kWh for winter, and the ratios of the power reductions are 84%, 3%, and 14%, respectively.
Abstract
Li-ion batteries are mainly used in energy storage system (ESS) systems, but they have the issue of significant battery fire incidents. Many thermal management technologies to respond to the heat load of batteries using phase change material (PCM) have been studied. We studied the thermal and power consumption properties depending on the charge/discharge and outside temperature of the ESS battery room through field survey data and an experiment. First, data for the heat pump power consumption and various temperature points of an ESS system were measured daily in the commercial operation of a 250 kWh PV-ESS for a year. Correlation analysis of the power consumption of a heat pump cooling and heating operation to maintain the temperature in the ESS battery room shows that the outside air temperature is the major factor. Furthermore, we conducted an experiment to determine the properties of temperature and power consumption by season at a fabricated ESS battery room with a 250 kWh Li-ion battery including 23°C PCM modules. PCM supports cooling and heating to maintain the room temperature as the heat pump operation cycles on and off. The ESS with applied PCM shows a reduction of heat pump power consumption and improved thermal management according to the load of the heating battery for charging/discharging and the day/night outside air temperature. The power consumptions for heating and cooling due to the battery heat load with a charging and discharging capacity of 150 kWh for each season condition for the only-heat-pump and PCM-applied system operations are 5.6 kWh and 0.88 kWh for changing seasons, 16.5 kWh and 15.8 kWh for summer, and 14.3 kWh and 12.2 kWh for winter, and the ratios of the power reductions are 84%, 3%, and 14%, respectively.
참고문헌 (12)
- Kim, D., "Operation Strategy of Shared ESS Based on Power Sensitivity Analysis to Minimize PV Curtailment and Maximize Profit", IEEE Access, 8, pp.197097~197110 (2020)
- Prajapati V. K., "Congestion Management of Power System with Integration of Renewable Resources and Energy Storage System", Proc. IEEE 8th Power India Int. Conf, pp.1~6 (2018)
- 정윤이, "에너지 저장 시스템 (ESS)용 배터리의 운전조건에 따른 성능 저하 및 태양광 연계형 ESS 모니터링 연구", 한국수소및신에너지학회논문집, 25(3), pp.311~318 (2014), 한국수소및신에너지학회[DOI]
- "Plan for Implementation of Renewable Energy 3020" (2019)[URL]
- Chen, J., "Effects of Different Phase Change Material Thermal Management Strategies on the Cooling Performance of the Power Lithium Ion Batteries: A Review", Journal of Power Sources, 442(1), pp.227228~ (2019)
- 김성은, "PCM을 적용한 패시브 및 액티브 기술의 에너지 절감 효과", 한국생활환경학회지, 29(4), pp.341~347 (2022), 한국생활환경학회[DOI]
- Ping, P., "Investigation on Thermal Management Performance of PCM-fin Structure for Li-ion Battery Module in High-temperature Environment", Energy Conversion and Management, 176(15), pp.131~146 (2018)
- Lazrak, A., "An Innovative Practical Battery Thermal Management System Based on Phase Change Materials: Numerical and Experimental Investigations", Applied Thermal Engineering, 128(5), pp.20~32 (2018)
- Ling, Z., "A Hybrid Thermal Management System for Lithium Ion Batteries Combining Phase Change Materials with Forced-air Cooling", Applied Energy, 148(15), pp.403~409 (2015)
- Wu, W., "An Experimental Study of Thermal Management System Using Copper Mesh-enhanced Composite Phase Change Materials for Power Battery Pack", Energy, 113(15), pp.909~916 (2016)
- Luo, J., "Battery Thermal Management Systems (BTMs) Based on Phase Change Material (PCM): A Comprehensive Review", Chemical Engineering Journal, 430(15), pp.132741~ (2022)
- Patel, J. R., "Recent Developments in the Passive and Hybrid Thermal Management Techniques of Lithium-ion Batteries,", Journal of Power Sources, 480(31), pp.228820~ (2020)