An efficient cooling system is an essential part of the electronic packaging such as a high-luminance LED lighting. A special technology, Pulsating Heat Pipe (PHP), can be applied to improve cooling of a sealed, explosion-proof LED light fixture. In this paper, the characteristics of the pulsating heat pipes in the imposed thermal boundary conditions of LED lightings were experimentally investigated and a PHP device that works free of alignment angle was investigated for cooling of explosion-proof LED lights. Five working fluids of ethanol, FC-72, R-123, water, and acetone were chosen for comparison. The experimental pulsating heat pipe was made of copper tubes of internal diameter of 2.1 mm, 26 turns. A variable heat source of electric heater and an array of cooling fins were attached to the pulsating heat pipe. For the alignment of the heating part at bottom, an optimum charging ratio (liquid fluid volume to total volume) was about 50% for most of the fluids and water showed the highest heat transfer performance. For the alignment of the heating part on top, however, only R-123 worked in an un-looped construction. This unique advantage of R-123 is attributed to its high vapor pressure gradient. Applying these findings, a cooling device for an explosion-proof type of LED light rated 30 W was constructed and tested successfully.
Abstract
An efficient cooling system is an essential part of the electronic packaging such as a high-luminance LED lighting. A special technology, Pulsating Heat Pipe (PHP), can be applied to improve cooling of a sealed, explosion-proof LED light fixture. In this paper, the characteristics of the pulsating heat pipes in the imposed thermal boundary conditions of LED lightings were experimentally investigated and a PHP device that works free of alignment angle was investigated for cooling of explosion-proof LED lights. Five working fluids of ethanol, FC-72, R-123, water, and acetone were chosen for comparison. The experimental pulsating heat pipe was made of copper tubes of internal diameter of 2.1 mm, 26 turns. A variable heat source of electric heater and an array of cooling fins were attached to the pulsating heat pipe. For the alignment of the heating part at bottom, an optimum charging ratio (liquid fluid volume to total volume) was about 50% for most of the fluids and water showed the highest heat transfer performance. For the alignment of the heating part on top, however, only R-123 worked in an un-looped construction. This unique advantage of R-123 is attributed to its high vapor pressure gradient. Applying these findings, a cooling device for an explosion-proof type of LED light rated 30 W was constructed and tested successfully.
참고문헌 (12)
- M.S. Yoon, "Present and future of lighting industry", Bulletin of KIEEME, 21, pp.21~26 (2008)
- M. H. Shin, "State of the art on a large output of power LED packaging", Physics & High Technology, pp.16~21 (2008), The Korea Physical Society,
- Groll M, "Pulsating Heat Pipes: Progress and Prospects", Proceeding of the International Conference on Energy and the Environment, 1, pp.723~730 (2003)
- Jong-SooKim, "Flow Visualization of Oscillation Characteristics of Liquid and Vapor Flow in the Oscillating Capillary Tube Heat Pipe", Journal of Mechanical Science and Technology, 17(10), pp.1507~1519 (2003), 대한기계학회
- S. Rittidech, "Heat-transfer characteristics of a closed-loop oscillating heat-pipe with check valves", Applied Energy, 84, pp.565~577 (2006)
- B. Y. Tong, "Closed-loop pulsating heat pipe", Applied Thermal Engineering, 21, pp.1845~1862 (2001)
- J. L. XU, "Start-up and steady thermal oscillation of a pulsating heat pipe", Heat Mass Transfer, 41, pp.685~694 (2005)
- P. Charoensawan, "Closed loop pulsating heat pipes – Part A: Parametric experimental investigations", Applied Thermal Engineering, 23, pp.2009~2020 (2003)
- S. Khandekar, "Understanding operational regimes of pulsating heat pipes: an experimental study", Applied Thermal Engineering, 23, pp.707~719 (2003)
- Honghai Yang, "Operational limit of closed loop pulsating heat pipes", Applied Thermal Engineering, 28, pp.49~59 (2008)
- Zhang, Yuwen, "Advances and Unsolved Issues in Pulsating Heat Pipes", Heat Transfer Engineering, 29(1), pp.20~44 (2008)
- H. T. Kim, "A Study on Cooling of Flameproof LED Lightings using Pulsating Heat Pipes", 석사, pp.2012