Analysis of the experimental cooling performance of a high-power light-emitting diode package with a modified crevice-type vapor chamber heat pipe

1

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류기계공학

초록

The experimental analysis of a crevice-type vapor chamber heat pipe (CVCHP) is investigated. The heat source of the CVCHP is a high-power light-emitting diode (LED). The CVCHP, which exhibits a bubble pumping effect, is used for heat dissipation in a high-heat-flux system. The working fluid is R-141b, and its charging ratio was set at 60 vol.% of the vapor chamber in a heat pipe. The total thermal conductivity of the falling-liquid-film-type model, which was a modified model, was 24% larger than that of the conventional model in the LED package. Flow visualization results indicated that bubbles grew larger as they combined. These combined bubbles pushed the working fluid to the top, partially wetting the heat-transfer area. The thermal resistance between the vapor chamber and tube in the modified design decreased by approximately 32%. The overall results demonstrated the better heat dissipation upon cooling of the high-power LED package.

Abstract

The experimental analysis of a crevice-type vapor chamber heat pipe (CVCHP) is investigated. The heat source of the CVCHP is a high-power light-emitting diode (LED). The CVCHP, which exhibits a bubble pumping effect, is used for heat dissipation in a high-heat-flux system. The working fluid is R-141b, and its charging ratio was set at 60 vol.% of the vapor chamber in a heat pipe. The total thermal conductivity of the falling-liquid-film-type model, which was a modified model, was 24% larger than that of the conventional model in the LED package. Flow visualization results indicated that bubbles grew larger as they combined. These combined bubbles pushed the working fluid to the top, partially wetting the heat-transfer area. The thermal resistance between the vapor chamber and tube in the modified design decreased by approximately 32%. The overall results demonstrated the better heat dissipation upon cooling of the high-power LED package.

참고문헌 (10)

  1. J. Hu, "Thermal and mechanical analysis of high-power LEDs with ceramic packages", IEEE Transactions, pp.297~303 (2008)
  2. I. Kim, "Thermal analyssis of LED array system with heat pipe", Thermochim, Acta, 455(1-2), pp.21~25 (2007)
  3. Y. Tang, "A high power LED divice with chips directly mounted on heat pipes", Applied Thermal Engineering, 66(1-2) (2014)
  4. J. W. Yeo, "Development of Cooling System for Automobile LED Headlamp using Heat Pipe with Crevice Type Vapor Chamber", M.S, Department of Refrigeration and Air-Conditioning Engineering, pp.2012
  5. J. W. Yeo, "LED headlamp cooling performance using crevice type vapor chamber", Proceedings of SAREK, pp.343~346 (2011)
  6. J. Heo, "Study on the development of high-efficiency heat dissipation device using vapor chamber type heat pipe for ships and offshore plants", Proceedings of the Korean Society of Mechanical Engineers, pp.231~235 (2013)
  7. B. D. Kang, "Evaluation of fule consumption between LED headlamp and halogen headlamp", KSAE 2009 Annual Conference, pp.1709~1714 (2009)
  8. 고만석, "팬과 히트 싱크를 이용한 LED 전조등의 냉각성능 해석", 대한기계학회논문집 B, 33(12), pp.947~951 (2009), 대한기계학회
  9. D. A. Ready, "Heat pipes" (2005), Butterworth Heinemann
  10. 감기술, "열전대 구조변화에 의한 열시정수 특성 변화", 센서학회지, 18(2), pp.103~109 (2009), 한국센서학회

관련 논문AI추천