본문 바로가기
KERD
논문KCI 등재

CFD analysis of the effect of different PAR locations against hydrogen recombination rate

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기계공학

초록

Many studies have been conducted on the performance of a passive autocatalytic recombiner (PAR), but not many have focused on the locations where the PAR is installed. During a severe accident in a nuclear reactor containment, a large amount of hydrogen gas can be produced and released into the containment, leading to hydrogen deflagration or a detonation. A PAR is a hydrogen mitigation method that is widely implemented in current and advanced light water reactors. Therefore, for this study, a PAR was installed at different locations in order to investigate the difference in hydrogen reduction rate. The results indicate that the hydrogen reduction rate of a PAR is proportional to the distance between the hydrogen induction location and the bottom wall.

Abstract

Many studies have been conducted on the performance of a passive autocatalytic recombiner (PAR), but not many have focused on the locations where the PAR is installed. During a severe accident in a nuclear reactor containment, a large amount of hydrogen gas can be produced and released into the containment, leading to hydrogen deflagration or a detonation. A PAR is a hydrogen mitigation method that is widely implemented in current and advanced light water reactors. Therefore, for this study, a PAR was installed at different locations in order to investigate the difference in hydrogen reduction rate. The results indicate that the hydrogen reduction rate of a PAR is proportional to the distance between the hydrogen induction location and the bottom wall.

참고문헌 (9)

  1. 송진호, "Severe Accident Issues Raised by the Fukushima Accident and Improvements Suggested", Nuclear Engineering and Technology, 46(2), pp.207~216 (2014), 한국원자력학회
  2. COGAP: A Nuclear Power Plant Containment Hydrogen Control System Evaluation code, "R. G. Gido", Los Alamos National Lab, ~, pp.NUREG (1983), CR-2847; LA-9459-MS ON: DE83006406
  3. W. Breitung, "Procedure and tools for deterministic analysis and control of hydrogen behavior in severe accidents", Nuclear Engineering and Design, 202(2-3), pp.249~268 (2000)
  4. E. Bachellerie, "Generic approach for designing and implementing a passive autocatalytic recombiner PAR-system in nuclear power plant containments", Nuclear Enginnering and Design, 221(1-3), pp.151~165 (2003)
  5. S. J Han, "An investigation of potential risks of nuclear system from hydrogen production", Nuclear Engineering and Design, 270, pp.119~132 (2014)
  6. E. A. Reinecke, "Studies on innovative hydrogen recombiners as safety devices in the containments of light water reactors", Nuclear Engineering and Design, 230(1), pp.49~59 (2004)
  7. J. Deng, "A study on evaluating a passive autocatalytic recombiner PAR-system in the PWR large-dry containment", Nuclear Engineering and Design, 238(10), pp.2554~2560 (2008)
  8. C. Appel, "Catalytic combustion of hydrogen-air mixtures over platinum: validation of hetero", homogenous chemical reaction schemes, 2004, pp.5(1), ~
  9. J. W. Park, "Demonstrative testing of honeycomb passive autocatalytic recombiner for nuclear power plant", Nuclear Engineering and Design, 241(10), pp.4280~4288 (2011)