Statement of problem: There are many articles that showed that the magnetism affected the bone formation around titanium implant. It means that a proper magnetism made the osseointegration improved around the implant. So after additional research on the other effect of magnetism on bone formation in implant therapy, we can conclude its possibility of clinical application on implant treatment. Purpose: The purposes of this study were to find out the intensity of magnetic field where magnetism in the titanium implant specimen inserted into the bone could affect the bone formation, and to discover the possibility of clinical application in the areas of dental implants and bone grafts. Material and method: Ten adult male rabbits(mean BW 2Kg) were used in this study. Titanium implant specimens were surgically implanted on the mesial side of the tibia of rabbits. Neodymium magnets(Magnedisc 500, Aichi Steel Corp. Japan) were placed into the implants of experimental group except control group, just after placement of the titanium implants. At 2, 4 and 8 weeks after the surgery, the animals were sacrificed, specimens were obtained and stained with Hematoxylin-Eosin for light microscopic evaluation and histomorphometric analysis. Conclusion: The results were as follows: 1. In radiographic findings, increased radiopacity downward from crestal bone was observed along the titanium implant specimen at experimental period passed by 2,4, and 8 weeks in both control and experimental group. 2. In histoiogic findings, increased new bone formation was shown in both control and experimental group through the experiment performed for 2,4, and 8 weeks. More new bone formation and bone remodeling were shown in experimental group. 3. In histomorphometric analysis, the bone contact ratios were 11.9% for control group and 38.5% for experimental group(p<0.05).

참고문헌 (25)

  1. "Electricallyinduced osteogenesis", pp.3~19 (1985)
  2. "Fundamental problems in the treatment offracture", 4, pp.395~406 (1953)
  3. "Piezoelectricity of living bone", 53, pp.325~ (1953), JKyoto PrefUniv Med
  4. "On the piezoelectriceffect of bone", 12, pp.1158~1162 (1957)
  5. "Augmentation of bone repair by inductivelycoupled electromagnetic fields", 184, pp.575~577 (1974)
  6. "Effects of electromagnetic fields in experimentalfracture repair", 355, pp.90~104 (1998)
  7. "A multicenter study of the treatment ofnon-union with constant current", 63, pp.2~13 (1981)
  8. "Treatment of recalcitrantnon-union with a capacitively coupledelectrical field", 67, pp.577~585 (1985)
  9. "A nonoperative salvage of surgically resistantpseudarthoses and nonunions bypulsing electromagnetic fields:a preliminaryreport", 1245, pp.128~143 (1977)
  10. "Overview of effects of electrical stimulationon osteogenesis and alveolar bone", 66, pp.1~10 (1995)
  11. "Electrical stimulationof osteogenesis in pathological osseousdefects", 47, pp.311~319 (1976)
  12. "Anew orthodontic force system of magneticbrackets", 92, pp.241~248 (1987)
  13. "Pulsed electromagneticfields promote bone formationaround dental implants inserted into thefemur of rabbits", 11, pp.354~360 (2000)
  14. "The Effect ofElectrical Stimulation on OsteoblastSurrounding Dental Implant", 19, pp.196~206 (2003)
  15. "Electrical stimulation of Hard andSoft Tissues in Animal Models", 12, pp.243~257 (1985)
  16. "Theeffects of electrical stimulation on thebone differentiation to the bone", 7, pp.501~507 (1980), Orthop ResSci
  17. "The electrical induction ofCallus Formation and external skeletal fixationusing methyl methacrylate for delayedunion of open tibial fracture with segmentalloss", 124, pp.92~96 (1977)
  18. "Pulsedelectromagnetic field stimulation of MG63osteoblast-like cells affects differentiationand local factor production", 18, pp.637~646 (2000)
  19. "The biological effects of implantedmagnetic fields on the bone tissue of dog", 6, pp.345~349 (1991)
  20. "Effects of staticmagnetic fields on bone formation of ratfemurs", 20, pp.397~402 (1998)
  21. "Effect of a static magnetic field on fracturehealing in a rabbit radius", 222, pp.300~306 (1987)
  22. "Strong static magnetic fieldstimulates bone formation to a definite orientationin vitro and in vivo", 17, pp.1814~1821 (2002)
  23. "Physical stress by magnetic force acceleratesdifferentiation of human osteoblasts", 311, pp.32~38 (2003)
  24. "The effect ofMagnetism(Neodymium)on Activity ofOsteoblast", 19, pp.186~193 (2003)
  25. "Effect of themagnetism(neodymium magnet)on growthfactor receptors of osteoblast", 19, pp.88~96 (2003)

관련 논문AI추천

티이타늄 임프랜트 시편 내부에 설치한 자석의 자성강도에 따른 골형성 변화이성복, 최대균, 최부병, 황윤태대한치과보철학회 · 대한치과보철학회지2005 · 제43권 제2호비침습적인 전기자극이 임프란트의 골융합에 미치는 영향 : 토끼경골에서의 조직계측학적 평가박진우, 서조영, 손성배대한치주과학회 · Journal of Periodontal & Implant Science2005 · 제35권 제3호임플란트에 연결한 영구자석이 임플란트 주위 뼈모세포의 분포와 부착에 미치는 영향에 관한 연구백진, 권긍록, 오나희, 이성복, 최부병대한치과보철학회 · 대한치과보철학회지2005 · 제43권 제4호가토 두개부 골결손에서 맥동전자기장이 골형성에 미치는 영향에 관한 연구김명진, 김종원, 신광섭, 이종환, 황경균대한구강악안면외과학회 · 대한구강악안면외과학회지2002 · 제28권 제4호임플랜트에 연결한 영구자석의 자력이 뼈의 세포외 기질 생성에 미치는 영향에 관한 실험실적 연구백진, 권긍록, 원인재, 이성복대한치과보철학회 · 대한치과보철학회지2006 · 제44권 제5호가토 두개골 결손부에 이식된 .-TCP의 골치유과정에서맥동전자기장의 영향에 관한 연구김상우, 박창주, 백승삼, 심광섭, 임병섭, 정일혁, 황경균대한구강악안면외과학회 · 대한구강악안면외과학회지2006 · 제32권 제4호

이 간행물의 다른 논문 (12건)