- "A 15-year study of osseointegrated im-94plants in the treatment of the edentulousjaw", pp.387~416, Bra nemarkPI
- "Long term evaluation of non submerged ITIimplants", 8, pp.161~172 (1997)
- "Osseoint-egrated implants for single-tooth re-placement Progress report from a multi-center prospective study after 3 years", pp.49~54
- "A multicenterretrospective analysis of the ITI implant system used for single tooth replacements Preliminary results at 6 or more months ofloading", 12, pp.237~242 (1997)
- "The Frialit 2 implantsystem Five year clinical experience in single tooth and immediately post extraction applications", 12, pp.299~309 (1997)
- "Osseoint-egrated implants for single tooth replace-ment A 1-year report from a multicenterprospective study", pp.29~36
- "The long-term efficacy of cur-rently used dental implants a reviewand proposed criteria of success", pp.11~25
- "Complications with osseointe-grated implants", pp.581~5
- "The longitudinalclincal effectiveness of osseointegratedimplants"
- "Failuresand complications in 127 consecutivelyplaced fixed partial prostheses supportedby Branemark implants From prosthet-ic treatment to first annual check up", pp.40~4
- "A5 year follow up study", pp.635~40
- "Loose gold screwsfrequently occur in full arch fixed prosthesessupported by osseointegrated implantsafter 5 years"
- "Fixed implant supported prost-heses in the edentulous maxilla", pp.142~7
- "Registration of localization occlusionand occluding materials for failing screw joints in the Bra nemark implant system", 6, pp.47~53 (1995)
- "Replacement ofmaxillary and mandibular molars withsingle endosseous implant restorations retrospective study", 74, pp.51~55 (1995)
- "A comparative study of one implant versus two replacing a single molar", 11, pp.372~378 (1996)
- "Implants and components Entering the new millennium", 15, pp.76~94 (2000)
- "An invitro evaluation of thestrength of an internal conical interfacecompared to a butt joint interface in implant design", 8, pp.290~298 (1997)
- "Assessment of cold weldingproperties of the internal conical interfacetwo commercially available implant systems", 81, pp.159~166 (1999)
- "Cemented versus screw retainedimplant prostheses Which is better?", 14, pp.138~139 (1999)
- "A mult icenter retrospective analysis of the ITI implant system used for singletooth replacements Results of loading for 2 of moreyears", 14, pp.516~520 (1999)
- "Crown to root ratio its significance in restorative dentistry", pp.34~8
- "A simple prosthetic approach using cement retained implant prosthesis after surgical treatment of ameloblastoma", 8, pp.407~412 (1999)
- "Stress analysis of porousrooted dental implants", pp.772~7
- "Three-dimen-sional stress distribution around a dentalimplant at different stages of interface de-velopment", pp.155~9
- "Americal society for metals" (1984)
- "How occlusal forces change in im plant patients", 126, pp.1130~ (1995)
- "Reduction of implant loading with therapeutic biomechanics", 7, pp.277~ (1998)
- "In vivo vertical forces on im plants", 10, pp.99~ (1995)
- "Implant protectedocclusion", 7, pp.25~ (1995)
- "Implant screw mechanics", 42, pp.71~89 (1998)
- "A 3-year follow-upstudy on single implant treatment", pp.203~8
- "Microbial leakage and marginal fit of the 96 implant abutment interface", 12, pp.527~540 (1997)
- "a compar-ison of ultimate failure force", pp.35~9
- "Comparativestudy of antirotational single tooth abutments", 73, pp.36~43 (1995)
- "The new restorative concept of theITI dental implant system", pp.409~31
- "The placement of mandibularposterior implants", pp.145~156 (1998)
- "Survival of the Bra nemark implantin partially edentulous jaws A 10yearprospective multicenter study", 14, pp.639~645 (1999)
- "Use of short endosseous implants andan overdenture in the extremely resorbedmandible a five year retrospective study", 58, pp.382~387 (2000)
- "Skinner’ s science of dentalmaterials" (1991)
- "Betatitaniumalloy for surgical implants", pp.2689~96 (1993), Steinemann SG
- "Nonlinearcontact analysis of preload in dental implantscrews", 10, pp.295~302 (1995)
관련 논문AI추천
수종의 임플랜트 시스템에 따른 유한요소법적 응력분석에 관한 연구박원희, 박주진, 유성현, 이영수대한치과보철학회 · 대한치과보철학회지2006 · 제44권 제2호임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석장종석, 정용태, 정재헌대한턱관절교합학회 · 구강회복응용과학지2005 · 제21권 제1호임플란트와 지대주간 내측 연결을 갖는 임플란트 보철의 유한요소 응력분석계기성, 안종관, 정재헌대한치과보철학회 · 대한치과보철학회지2004 · 제42권 제4호임프란트와 지대주 간 내측 연결을 갖는 2종의 임프란트에서 저작압이 임프란트 주위골 내응력 분포에 미치는 영향에 관한 연구유미경, 임성빈, 정진형, 홍기석대한치주과학회 · Journal of Periodontal & Implant Science2006 · 제36권 제2호내측연결 시스템에서 임플란트 고정체의 경부 형태에 따른 지지골에서의 유한요소 응력분석김희중, 박영남, 오상호, 정재헌대한턱관절교합학회 · 구강회복응용과학지2006 · 제22권 제1호3차원 유한요소법적 분석을 이용한 5종의첨형 임플랜트에 발생하는 응력의 비교연구박원희, 변상기, 이영수대한치과보철학회 · 대한치과보철학회지2006 · 제44권 제5호
이 간행물의 다른 논문 (11건)
투명 fiber 포스트를 통한 광중합형 접착레진의 중합 반응박상원, 양홍서, 안석, 방몽숙, 박하옥pp. 1-9다양한 포스트와 코어의 물성이 근관치료된 치근의 응력분산에 미치는 영향이청희, 조진현pp. 10-19주조티타늄과 기계절삭티타늄 코핑의 변연적합성에 관한 연구박상원, 박하옥, 오수연, 양홍서, 방몽숙pp. 20-28CAD/CAM을 이용한 구치부 전부도재 고정성 국소의치 지르코니아 코어의 연결부 설계에 따른 파절강도박인임, 이근우, 서준용pp. 29-39Periotest Value와 Implant Stability Quotient에 영향을 미치는 요소이영아, 이호용, 차인호, 한동후pp. 40-50