논문KCI 등재
타이타늄 상악 주연결장치에 디자인에 따른 주조성 및 견고성 비교
2
조회
0
다운로드
0
인용
0
참고문헌
주제분류치의학
초록
Abstract
3. For titanium major connector, less strain rate was observed when the force is appliedto the first premolar area rather than to the second molar area indicating more strengthwith shorter length of lever.4. In comparison of Co-Cr major connector with titanium major c onnector, palatal strapand U-shaped bar designs showed higher strength under torsional force that is stat-ically significant, and under compressive force, no significant difference was observed
참고문헌 (32)
- "The effect ofdesign modifications on the torsional andcompressive rigidity of U-shaped palatal ma-jor connectors", 89, pp.400~440 (2003)
- "Casting titanium partialdenture frameworks: A radiographic eval-uation", 87, pp.277~283 (2002)
- "Comparative study ofcircumferential clasp retention force fortitanium and cobalt-chromium removablepartial dentures", 88, pp.290~296 (2002)
- "Effect of partial denture designon bilateral force distribution", pp.373~85
- "Design of partial denturecomponents", pp.586~9
- "Lateral force dis-tribution in partial denture design", pp.359~64
- "Stress analysis in distal ex-tension partial dentures"
- "DentalClinics of North America 1973;17", pp.661~78
- "Stiffness of different designs and cross-sec-tions of maxillary and mandibular majorconnectors of removable partial dentures", 81, pp.526~532 (1999)
- "Deformation properties of Ti-6Al-7Nb alloy castings for removable par-tial denture frameworks", 23, pp.497~503 (2004)
- "Maintaining supportingstructures with a removable partial pros-thesis", pp.167~74
- "Comparison of ti-tanium and cobalt-chromium removable par-tial denture clasps", 78, pp.507~516 (1997)
- "Comparison ofmajor connectors for removable partialdentures", pp.242~4
- "Selection of a majorconnector for the extension-base removablepartial denture", pp.102~6
- "The ef-fect of the major connector on abutmenttooth and denture base movement", pp.545~9
- "Comparison ofDeformation by stereophotogrammetry ofVarious kinds of major connectors in max-illary Kennedy Class I removalble partialdentures", 14, pp.71~76 (2001)
- "The distortion of cast cobalt-chromium alloy partial denture frameworks fitted toa working cast", 78, pp.382~391 (1997)
- "Rigidity of major connectors whensubjected to bending and torsion forces", pp.557~62
- "Aphotoelastic study of a split palatal majorconnector"
- "Titanium for prostho-dontics applications: A review of the lit-erature", 27, pp.401~408 (1996)
- "Comparisonof castability and surface roughness ofcommercially pure titanium and cobalt-chromium denture frameworks", 86, pp.93~98 (2001)
- "Accuracy of titani-um RPD castings Journal of DentalResearch"
- "Titanium for removable dentures. I.Laboratory procedures", 24, pp.338~341 (1997)
- "Internal porosity of casttitanium removable partial dentures:Influence of sprue direction on porosity incircumferential clasps of a clinical frame-work design", 88, pp.151~158 (2002)
- "Enha-ncement of a titanium denture framemodel: mold temperature and spruingfactors", 14, pp.256~262 (1995)
- "The effects of sprue design on theroughness and porosity of titanium cast-ings", 78, pp.400~404 (1997)
- "Titaniumfor removable partial dentures. II. Two-yearclinical observations", 24, pp.414~418 (1997)
- "Titanium for removable partialdentures (III): 2-year clinical follow-up inan undergraduate programme", 27, pp.979~985 (2000)
- "A short-term clin-ical follow-up study of superplastic titaniumalloy for major connectors of removablepartial dentures", 77, pp.583~587 (1997)
- "Effect of casting technique on sur-face roughness and consequent mass lossafter polishing of Ni-Cr and Co-Cr base met-al alloys: A comparative study with tita-nium", 92, pp.274~277 (2004)
- "Cobalt-chromium and nickel-chromi-um alloys for removable prosthodontics", pp.144~50
- "Advances in Dental research 1992;24"
관련 논문AI추천
컴퓨터 시뮬레이션을 이용한 임플란트 상부 티타늄구조물의 주조방안심준성, 오세욱, 이근우, 이호용대한치과보철학회 · 대한치과보철학회지2003 · 제41권 제4호주입선 형태가 티타늄 주조관의 변연재현성에 미치는 영향박재경, 전영찬, 정창모대한치과보철학회 · 대한치과보철학회지2002 · 제40권 제4호임플란트 고정체와 지대주 연결 형태의 차이에 따른 유지 나사 안정성에 대한 연구방몽숙, 양재식, 조규종대한치과보철학회 · 대한치과보철학회지2004 · 제42권 제1호티타늄과 니켈-크롬 합금의 도재결합강도 비교박세영, 전영찬, 정창모대한치과보철학회 · 대한치과보철학회지2003 · 제41권 제1호유지구 설계가 주조연결강도에 미치는 영향에 관한 삼차원 유한요소법적 연구김정우, 윤미정, 전영찬, 정창모대한치과보철학회 · 대한치과보철학회지2009 · 제47권 제1호임플랜트-지대주의 연결방법에 따른 임플랜트 보철의 유한요소 응력분석계기성, 정재헌, 허진경대한치과보철학회 · 대한치과보철학회지2005 · 제43권 제4호
이 간행물의 다른 논문 (11건)
불산 식각 농도 및 시간이 lithium disilicate 도재와레진시멘트의 전단결합강도에 미치는 영향서재민, 박찬운, 안승근pp. 407-418도재 수리시스템에 따른 도재와 복합레진의 전단결합강도김경규, 이정렬, 김영수, 신상완pp. 419-430하악피개의치에서 임플랜트의 식립각도에 따른칸틸레버 길이의 감소효과가 응력분포 양상에 미치는 영향 -삼차원 유한요소법을 이용한 분석-이성복, 박준수, 권긍록, 우이형pp. 444-456수종의 실란처리 유리섬유를 첨가한 의치상용 레진의강도변화 및 마모전?후 표면성상분석김명주, 김창회, 임영준, 이상일, 윤석대pp. 457-468다양한 골질에서 임플랜트 수용부 형성방법이 임플랜트 1차 안정성에 미치는 영향방몽숙, 오희균, 최득철pp. 469-481
