논문KCI 등재
Detorque force of TiN-coated abutment screw with various coating thicknessafter repeated closing and opening
1
조회
0
다운로드
0
인용
0
참고문헌
주제분류치의학
참고문헌 (31)
- "Clinical complications of osseointegrated im-plants", 81, pp.537~552 (1999)
- "Implant abutment screw rotations and preloads forfour different screw materials and surfaces", 86, pp.24~32 (2001)
- "Single-tooth restorations supported by osseointegrated im-778plants : Results and experiences from a prospectivestudy after 2 to 3 years", 10, pp.702~711 (1995)
- "Clinical effectiveness ofimplant-supported single tooth replacement : theToronto study", 11, pp.311~321 (1996)
- "A study on the fit of the im-plant-abutment-screw interface", 41(4), pp.503~518 (2003)
- "Harris D. Osseointegrated im-plants for single tooth replacement: A 1-year reportfrom a multicenter prospective study. Int J OralMaxillofac Implants 1991", pp.~36
- "van Steenberghe D. A six-yearprosthodontic study of 509 consecutively insertedimplants for the treatment of partial edentulism.J Prosthet Dent 1992", pp.~245
- "Clinical complications with implants and implantprostheses", 90, pp.121~132 (2003)
- "Implant prosthodontic and restora-tive complications", 18, pp.766~767 (2003)
- "Cement-retained versusscrew-retained implant restorations: Achievingoptimal occlusion and esthetics in implant dentistry", 77, pp.28~35 (1997)
- "Implantscrew mechanics", 42, pp.71~89 (1998)
- "Jorneus L. Forces and mo-ments of Branemark implants. Int J Oral MaxillofacImplants 1989", pp.~247
- "The anterior can-tilever in the implant-supported screw-retainedmandibular prosthesis", 89, pp.244~249 (2003)
- "Patterson EA.Tightening characteristics for screwed joints inosseointegrated implants. J Prosthet Dent 1994", pp.~599
- "Elongation and preload stress in dental implantabutment screws", 10, pp.529~535 (1995)
- "The effect of implant", abutment hexag-onal misfit on screw joint stability, 1996, pp.9, 149~160
- "Motosh N. Development of design charts for boltspreloaded up to the plastic range. J Eng Ind 1976:98:849-851."
- "Implants and components : Entering thenew millenium", 15, pp.76~94 (2000)
- "Influence of Tungsten Carbide", Carbon coat-ing on the preload of implant abutment screws, 2006, pp.44(2), 229~242
- "A clinical study of the efficacy of Gold-Tite square abutment screws in cement-retained im-plant restorations", 18(2), pp.273~278 (2003)
- "Creugers NH. Titanium nitride coat-ings in clinical dentistry. J Dent 1992", pp.~344
- "Surface change andfit of TiN-coated abutment screw after repeated clos-ing and opening", 45(1), pp.119~130 (2007)
- "King T. Tightening char-acteristics for screwed joints in osseointegrated den-tal implants. J Prosthet Dent 1994", pp.~599
- "Effects of surfacecoating on the screw release of dental implantscrew", 42(2), pp.210~225 (2004)
- "Effect of TiN coat-ing of abutment screw on detorque force", 45(3), pp.329~344 (2007)
- "Mechanical properties of TiNcoated film with various coating thickness on ti-tanium alloy" (2007)
- "Implantscrew mechanics and the settling effect : Anoverview", 29, pp.242~245 (2003)
- "Carlsson L. Loads and designsof screw joints for single crowns supported byosseointegrated implants. Int J Oral MaxillofacImplants 1992", pp.~359
- "Nonlinear contactanalysis of preload in dental implant screws", 10, pp.295~302 (1995)
- "Sopwith DG. The distribution of load in screwthreads. Proc Inst Mech Eng 1948", pp.~383
- "Gross MD. Effect of repeated"
관련 논문AI추천
Effect of TiN coating of abutment screw on detorque force김희중, 정재헌, 주한철대한치과보철학회 · 대한치과보철학회지2007 · 제45권 제3호Abrasion of abutment screw coated with TiN김희중, 손미경, 정석원, 정재헌대한치과보철학회 · The Journal of Advanced of Prosthodontics2009 · 제1권 제2호치과용 임플란트 나사의 풀림에 미치는 표면코팅 효과구철인, 정재헌, 최한철대한치과보철학회 · 대한치과보철학회지2004 · 제42권 제2호Changes of abutment screw after repeated closing and opening김희중, 오상호, 정재헌, 최한철대한치과보철학회 · 대한치과보철학회지2004 · 제42권 제6호DLC 표면 처리에 따른 임플랜트 지대주 나사의 풀림 현상에 관한 연구곽재영, 이광렬, 이종엽, 임순호, 장익태, 허성주대한치과보철학회 · 대한치과보철학회지2003 · 제41권 제2호Effects of TiN Coating on the Fatigue Fracture of Dental Implant System with Various Cyclic Loads손미경, 정다운, 정재헌, 최한철한국표면공학회 · 한국표면공학회지2015 · 제48권 제6호
이 간행물의 다른 논문 (10건)
A strain gauge analysis of implant-supported cantilevered fixed prosthesis under distal static load장익태, 허성주, 곽재영, 김성균, 손병섭pp. 717-723The effect of thickness of the provisional crown and fixed partial denturematerials on the translucency and masking effect김성훈, 이석형, 배아란, 제현지pp. 724-734The effect of monomer to powder ratio on polymerization shrinkage-strainkinetics of polymer-based provisional crown and fixed partial denture materials김성훈pp. 735-742Effect of surface treatment methods on the shear bond strength of resincement to zirconia ceramic류재준, 신상완, 서기원, 이호정pp. 743-752Biomechanics of abutments supporting removable partial dentures underunilateral loading이주희, 김성균, 곽재영, 허성주, 이정택, 로현기, 김효진, 이석형pp. 753-759