치과용 임플란트 나사의 풀림에 미치는 표면코팅 효과
EFFECTS OF SURFACE COATING ON THE SCREW RELEASE OF DENTAL IMPLANT SCREW
1
조회
0
다운로드
0
인용
0
참고문헌
초록
Abstract
Statement of problem: Implant screw loosening has been remained problem in restorative practices. Surface treatment of screw plays a role of preventing screw from loosening in implant screw mechanism. Purpose: The purpose of this study was to investigate surface characteristics of TiN and ZrN film ion plated screw with titanium and gold alloy screw and to evaluate wear resistance, surface roughness, and film adhesion on screw surface using various instruments. Material and methods: GoldTite screws and titanium screws provided by 3i (Implant Innovation, USA) and TorqTite screws or titanium screws by Steri-Oss (Nobel Biocare, USA) and gold screws and titanium screws by AVANA (Osstem Implant, korea) were selected. Ion plating which is much superior to other surface modification techniques was carried out for gold screws and titanium screws using Ti and Zr coating materials with nitrogen gas. Ion nitrided surface of each abutment screw was observed with field emission scanning electron microscopy(FE-SEM), micro-diamond scratch tester, vickers hardness tester, and surface roughness tester. Results: 1) The surface of gold screw and GoldTite is more smooth than ones of other kinds of non coated screw. 2) The ZrN and TiN coated surface is the more smooth than ones of other kinds of screw. 3) The hardness of TiN and ZrN coated surface showed higher than that of non coated surface. 4) The TiN coated titanium screw and ZrN coated gold screw have a good wear resistance and adhesion on the surface. 5) The surface of ZrN coated screw showed low surface roughness compared with the surface of TiN coated screw. Conclusion: It is considered that the TiN and ZrN coated screw which would prevent a screw from loosening can be appilcable to implant system and confirmed that TiN and ZrN film act as lubricant on surface of screw due to decrease of friction for recycled tightening and loosening.
참고문헌 (27)
- Albrektsson T, "Osseointegrated titaniumimpla", pp.155~70, nemark PI
- Richard LB, "Tighteningcharacteristics for screwed joints in osseointegrateddental implants", 71, pp.592~529 (1994)
- McGlumpy EA, "Optimum torque values for implant abutmentscrews", 72, pp.191~3 (1993)
- Shedden BA, "Significanceof nitrogen mass transfer mechanism on thenitriding behavior of austenitic stainlesssteel", pp.935~9
- Larry CB, "Torque required to loosen single-toothimplant abutment screw before and aftersimulated function", 6, pp.435~9 (1993)
- Kim H, "Corrosion of stainlesssteel, nickel-titanium, coated nickel-titanium,and titanium orthodontic wires.", 69, pp.39~44 (1999)
- Will CM, "Implant abutment screw rotations andpreloads for four different screw materialsand surface", 86, pp.24~32 (2001)
- Charles JG, "Clinical complications of osseointegrated implants", 81, pp.537~52 (1999)
- Miller RB, "Comparison of abutment screw preload indifferent implant designs" (1994)
- Motosch N, "Development of design chartsfor bolts preloaded up to the plastic range", 98, pp.849~51 (1976)
- Burguette RL, "Tightening characteristic for screwedjoint in osseointegrated dental implant", 71, pp.592~5 (1994)
- Gil FJ, "Improvementof the friction behavior of NiTi orthodonticarchwires by nitrogen diffusion", 8, pp.335~42 (1988)
- Cui FZ, "Hgihly adhesivehydroxyapatite coatings on titanium alloyformed by ion beam assited depostion", 8, pp.403~5 (1997)
- Motosch N, "Development of design chartsfor bolts preloaded up to the plastic range", 98, pp.849~51 (1976)
- Keating K, "Connecting abutments to dentalimplants", pp.43~6 (2001)
- Haack JE, "Determination of preload stress indental implant screws"
- Shin JH, "Metals as Biomaterials", 3, pp.28~38 (1999)
- US Patent 5, "Retrpspective review of 1170 endosseousimplants placed in partially edentulousjaws", pp.257 415~367 21 (1993)
- Perry AJ, "The residual stress in TiN films depositedonto cemented carbide by high-ratereactive sputtering", pp.387~95 (1989)
- Martin WC, "Implant abutment screw rotations andpreloads for four different screw materialsand surfaces", 86, pp.24~32 (2001)
- Koak JY, "The study on the removaltorque of the diamond like carbon coatedtitanium abutment screws", 41, pp.128~35 (2003)
- Calister WD, "Materials Science andEngineering An Introduction", pp.30~59 (2000), .Jhon Willey & Sons, Inc
- Thornton JA, "edited by Vossen JL and KernW", pp.75~118, Academic Press 1978
- Porter SS, "Increasing implantabutmentpreload by thin-gold coatingabutment screws", 77, pp.~837 (1998)
- William JD, "Dental Materials and their selection.2nd Edition", pp.16~7 (1997), Quintessence PublishingCo Inc
- Jemt T, "Osseointegrated implants for single toothreplacement:A 1-year report from a multicenterprospective study", 6, pp.29~36 (1991)
- Binon PP, "Implants and components:Entering the new millennium", 15, pp.76~94 (2000)
