Purpose: The image registration of radiographic image and digital surface data is essential in the computer-guided implant guide system. The purpose of this study was to examine the effects of using micro-screw on the working time and convenience of operators in the process of image matching for guided implant surgery. Materials and methods: A mandibular dental model was prepared in partial edentulism for Kennedy class I classification. Two micro-screws were placed on the each side of retromolar area. Radiographic and scan images were taken using computed-tomography and digital scanning. The images were superimposed by 12 operators in software in two different conditions: using remaining teeth image alone and using teeth and micro-screws images. Working time, operator convenience and satisfaction were obtained, and analyzed using the Mann-Whitney U test (α=.05). Results: The working time was not statistically different between image registration conditions (P>.05); however, operator convenience and satisfaction were higher in the teeth and micro-screw assisted condition than in the teeth-alone assisted condition (P<.001). Conclusion: The use of microscrew for the image registration has no effect in working time reduction, but improves operator convenience and satisfaction.

Abstract

Purpose: The image registration of radiographic image and digital surface data is essential in the computer-guided implant guide system. The purpose of this study was to examine the effects of using micro-screw on the working time and convenience of operators in the process of image matching for guided implant surgery. Materials and methods: A mandibular dental model was prepared in partial edentulism for Kennedy class I classification. Two micro-screws were placed on the each side of retromolar area. Radiographic and scan images were taken using computed-tomography and digital scanning. The images were superimposed by 12 operators in software in two different conditions: using remaining teeth image alone and using teeth and micro-screws images. Working time, operator convenience and satisfaction were obtained, and analyzed using the Mann-Whitney U test (α=.05). Results: The working time was not statistically different between image registration conditions (P>.05); however, operator convenience and satisfaction were higher in the teeth and micro-screw assisted condition than in the teeth-alone assisted condition (P<.001). Conclusion: The use of microscrew for the image registration has no effect in working time reduction, but improves operator convenience and satisfaction.

참고문헌 (21)

  1. Rungcharassaeng K, "Accuracy of computer-guided surgery : A comparison of operator experience", J Prosthet Dent, 114, pp.407~413 (2015)
  2. Kola MZ, "Surgical templates for dental implant positioning; current knowledge and clinical perspectives", Niger J Surg, 21, pp.1~5 (2015)
  3. Nickenig HJ, "Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical(guide)templates", J Craniomaxillofac Surg, 35, pp.207~211 (2007)
  4. Ganz SD, "Three-dimensional imaging and guided surgery for dental implants", Dent Clin North Am, 59, pp.265~290 (2015)
  5. Gargari M, "Development of patient-based questionnaire about aesthetic and functional differences between overdentures implant-supported and overdentures tooth-supported. Study of 43 patients with a follow up of 1 year", Oral Implantol (Rome), 5, pp.86~91 (2013)
  6. Schneider D, "A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry", Clin Oral Implants Res, 20, pp.73~86 (2009)
  7. Van Assche N, "Accuracy assessment of computer-assisted flapless implant placement in partial edentulism", J Clin Periodontol, 37, pp.398~403 (2010)
  8. 이두형, "Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study", The Journal of Advanced of Prosthodontics, 8(3), pp.207~213 (2016), 대한치과보철학회[DOI]
  9. Flügge T, "Registration of cone beam computed tomography data and intraoral surface scans-A prerequisite for guided implant surgery with CAD", CAM drilling guides, 2017, pp.28, 1113~1118
  10. DE Vico G, "Computer-assisted virtual treatment planning combined with flapless surgery and immediate loading in the rehabilitation of partial edentulies", Oral Implantol(Rome), 5, pp.3~10 (2012)
  11. Kim JE, "Accuracy of intraoral digital impressions using an artificial landmark", J Prosthet Dent, 117, pp.755~761 (2017)
  12. Oh JH, "Digital workflow for computer-guided implant surgery in edentulous patients : A case report", J Oral Maxillofac Surg, 75, pp.2541~2549 (2017)
  13. Widmann G, "Flapless implant surgery in the edentulous jaw based on three fixed intraoral reference points and imageguided surgical templates : accuracy in human cadavers", Clin Oral Implants Res, 21, pp.835~841 (2010)
  14. Lee DH, "Strategic use of microscrews for enhancing the accuracy of computer-guided implant surgery in fully edentulous arches : A case history report", Int J Prosthodont, 31, pp.262~263 (2018)
  15. Mai HN, "Optimizing accuracy in computer-guided implant surgery with a superimpositionanchor microscrew system : A clinical report", J Prosthet Dent, 120, pp.789.e1~789.e5 (2018)
  16. Orentlicher G, "Guided surgery for implant therapy", Oral Maxillofac Surg Clin North Am, 23, pp.239~256 (2011)
  17. Tahmaseb A, "Computer technology applications in surgical implant dentistry : a systematic review", Int J Oral Maxillofac Implants, 29, pp.25~42 (2014)
  18. Chen X, "Modular preoperative planning software for computer-aided oral implantology and the application of a novel stereolithographic template : a pilot study", Clin Implant Dent Relat Res, 12, pp.181~193 (2010)
  19. Jung RE, "Computer technology applications in surgical implant dentistry : a systematic review", Int J Oral Maxillofac Implants, 24, pp.92~109 (2009)
  20. Hultin M, "Clinical advantages of computer-guided implant placement : a systematic review", Clin Oral Implants Res, 23, pp.124~135 (2012)
  21. Scherer U, "Template-guided vs. non-guided drilling in site preparation of dental implants", Clin Oral Investig, 19, pp.1339~1346 (2015)

관련 논문AI추천

술자의 영상정합의 경험이 컴퓨터 단층촬영과 광학스캔 영상 간의 정합 정확성과 작업시간에 미치는 영향이두형, 마이항나대한치과보철학회 · 대한치과보철학회지2021 · 제59권 제3호디지털 가이드 수술의 이해와임상적 적용권긍록, 김형섭, 노관태, 배아란, 백장현, 이현종, 홍성진대한치과의사협회 · 대한치과의사협회지2018 · 제56권 제11호An assessment of template-guided implant surgery in terms of accuracy and related factors김명주, 김명진, 김성민, 박지만, 이재호, 이종호대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제4호Effects of a modified surgical protocol on the positional accuracy of dental implants placed using fully guided implant surgery in the partially edentulous posterior ridge with distal extension: a dentiform model study송영우, 유승하, 정의원대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제1호A Survey of Surgeons' Satisfactory Level on Using Zero-Setup Implant Surgical Guide System박정철, 신현승, 안일섭, 조인우, Pham Doung Hieu대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2022 · 제26권 제4호Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study안서영, 이규복, 이두형, 전경배, 홍민호대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제3호

이 간행물의 다른 논문 (14건)