임프란트 고정체와 지대주 직경의 차이가 응력분포에 미치는 영향
THE EFFECT OF THE DIFFERENCE OF THE IMPLANT FIXTURE AND ABUTMENT DIAMETER FOR STRESS DISTRIBUTION
2
조회
0
다운로드
0
인용
0
참고문헌
초록
Abstract
Statement of problem: Stress concentration on the neck bone affects the bone resorption, and finally the implant survival Purpose: In order to examine the stress distribution on the neck bone and prosthesis abutment for implants, decreasing abutment sizes were used. Material and methods: Axisymmetric models were used to obtain the data required. These models were composed of 4mm implants with 3.4mm and 4mm abutments, 5mm implants with 3.4mm and 5mm abutments and 6mm implants with 3.4mm and 6mm abutments. All abutments were designed to received a 10mm high by 10mm diameter gold crown. Functional element analysis was used to obtain these results using data that consisted of 50 N vertical and 45 degree inclination forces. Results: 1. Changing the diameter of the abutment on the implant affects the effect of the inclination forces more than the effect of the vertical forces. 2. Changing the diameter of the abutment on the implant affects the effect of the inclination forces more than the effect of the vertical forces. 3. Experimentation showed that the larger diameter implants provided a decreased neck bone stress, whereas a larger diameter abutment provided a decrease marginal abutment stress. 4. Experimentation showed that the neck bone and abutment received more stress from inclination forces than vertical forces. Conclusions: By decreasing the size of the abutment on the implant we were able to diminishneck bone stress.
참고문헌 (27)
- "Comparison of load transferby implant abutments of various diameters", 5, pp.79~83 (1997)
- "Finite elementanalysis of stress distribution with loadtransfer characteristics of the implant", boneinterface, 2003, pp.22, 48~56
- "Evaluating parametersof osseointergated dental implant using finiteelement analysis a two-dimensionalcomparative study examining the effects ofimplant diameter, implant shape, andload direction", 24, pp.80~88 (1998)
- "A finite element stress analysisof the bone around implant following cervicalbone resorption", 22(1), pp.38~48 (2003)
- "Evaluation ofdesign parameters of osseointegrated dentalimplants using finite element analysis", 29, pp.565~574 (2002)
- "Three-dimensional finite elementanalysis of stress-distribution around singletooth implants as a function of bony support,prosthesis type, and loading duringf", 67(6), pp.633~640 (1996)
- "Stress analysis around implantsystem using an axiosymmetric modellingapproach" (2002)
- "Biomaterials andbiomechanics of oral and maxillofacialimplants: Current status and future developments", 15, pp.15~46 (2000)
- "Mechanical loading of Branemark implantsaffects interfacial bone modellingand remodelling", 9, pp.345~360 (1994)
- "Bone resorption around fixtures in edentulouspatients treated with mandibularfixed tissue-integrated prostheses", 59, pp.59~63 (1988)
- "Strategies to affectbone remodelling", 8, pp.583~593 (1993)
- "Three-dimensionalstress distribution around a dental implantat different stages of interface development", 62, pp.155~159 (1983)
- "A 15year study of osseointegrated implantsin edentulous jaw", 10, pp.387~416 (1981)
- "Studiesof osseointegrated implant-models onstress distribution", 38, pp.526~542 (2000)
- "Two dimensional FEM analysis of hy-droxyapatite implants: Diameter effects onstress distribution.", 16(6), pp.6~11 (1990)
- "Finiteelement survey of eleven endosseous implants", 63(4), pp.457~465 (1990)
- "Use of an axisymmetric finite elementmethod to compare maxillary bone availablesfor a loaded implant", 2, pp.183~189 (1993)
- "Implant design consideration forthe posterior regions of the mouth", 8(4), pp.376~385 (1999)
- "Bone dentistry, A key derterminantfor clinical success in contempororyimplant dentistry", pp.109~118 (1999), Mosby yearbook. Inc
- "Radiographic assessment ofperi-implant vertical bone loss, DICRGinterim report No 9", 55(5), pp.62~71 (1997)
- "Functional surface area:thread form anddiameter optimization for implant body design", 19, pp.4~9 (1998)
- "Finiteelement stress analysis of implant prosthesisaccording to platform width of fixture", 41(5), pp.674~688 (2003)
- "Bone stress distribution forthree endosseous implants", 61(2), pp.223~228 (1989)
- "Five-mm-diameter implants without asmooth surface collar:Report on 98 consecutiveplacements", 14, pp.101~107 (1999)
- "Microleakage at the abutment-implantinterface of osseointergrated implants", 14, pp.94~100 (1999)
- "Forcetransfer by osseointegration implants devices", 1, pp.11~14
- "Quanification of compressivestresses and it’s effects on bone remodelling", pp.90~3