본문 바로가기
KERD
논문KCI 등재

의치상용 자가중합레진의 중합조건에 따른 파괴인성

FRACTURE TOUGHNESS OF SELF-CURING DENTURE BASE RESINS WITH DIFFERENT POLYMERIZING CONDITIONS

0

조회

0

다운로드

3

인용

0

참고문헌

주제분류치의학

초록

Abstract

Purpose. The intent of this study was to evaluate the effects of curing conditions on selfcuring denture base resins to find out proper condition in self-curing resin polymerization. Materials and methods. In this study, 3 commercial self-curing denture base resins are used: Vertex SC, Tokuso Rebase and Jet Denture Repair Acrylic. After mixing the self curing resin, it was placed in a stainless steel mold(3×6×60mm). The mold containing the resin was placed under the following conditions: in air at 23℃; or in water at 23℃; or in water at 23℃ under pressure(20psi); or in water at 37℃ under pressure(20psi); or in water at 50℃ under pressure(20psi); or in water at 65℃ under pressure(20psi), respectively. Also heatcuring denture base resin is polymerized according to manufacturers’instructions as control. Fracture toughness was measured by a single edge notched beam(SENB) method. Notch about 3mm deep was carved at the center of the long axis of the specimen using a dental diamond disk driven by a dental micro engine. The flexural test was carried out at a crosshead speed 0.5mm/min and fracture surface were observed under measuring microscope. Results and conclusion. The results obtained were summarized as follows : 1. The fracture toughness value of self-curing denture base resins were relatively lower than that of heat-curing denture base resin. 2. In Vertex SC and Jet Denture Repair Acrylic, higher fracture toughness value was observed in the curing environment with pressure but in Tokuso Rebase, low fracture toughness value was observed but there was no statistical difference. 3. Higher fracture toughness value was observed in the curing environment with water than air but there was no statistical difference. 4. Raising the temperature in water showed the increase of fracture toughness.

참고문헌 (10)

  1. "DentalMaterials" (1995), Koonja Publishing Inc p159-90
  2. "Effect of polymerization temperature andtime on the residual monomer content ofdenture base polymers", 106, pp.588~93 (1998)
  3. "Physical properties of acrylic resin poly-merized by four different techniques", 54, pp.522~4 (1985)
  4. "Thelevel of residual monomer in self-curing den-ture-base materials", 62, pp.118~20 (1983)
  5. "Effect of glass fiber rein-forcement on some mechanical proper-ties of autopolymerizing polymethylmethacrylate", 79, pp.580~4 (1998)
  6. "The effect of vacuum-mixed autopoly-merizing acrylic resins on porosity andtransverse strength", 60, pp.517~9 (1988)
  7. "Effect ofwater temperature during polymerizationon strength of autopolymerizing resin", 84, pp.222~4 (2000)
  8. "Thelevel of residual monomer in self-curing den-ture-base materials", 62, pp.118~20 (1983)
  9. "Influence of thickness and locationon the residual monomer content of den-ture base cured by three processing meth-ods", 72, pp.19~22 (1994)
  10. "Conversion in den-ture base polymers", 16, pp.741~54 (1982)

관련 논문AI추천

이 간행물의 다른 논문 (9건)