임플랜트 지대주 나사와 드라이버의 설계가 보철물 장착 및 철거 시간에 미치는 영향에 관한 연구
THE EFFECTS OF THE DESIGN OF ABUTMENT SCREW DRIVER ON THE AMOUNT OF TIME FOR INSERTION OF SCREW DRIVER INTO ABUTMENT SCREW HEAD
0
조회
0
다운로드
1
인용
0
참고문헌
초록
Abstract
Statement of problem. Implant screw loosening has been remained a problem in implant prosthodontics. The time needed to insert screw driver into abutment screw head should be shortened for the purpose of decreasing the chair time. Purpose. The purpose of this study was to investigate the effects of the design of abutment screw driver on the amount of time for insertion of screw driver into abutment screw head. Material and methods. Hexagonal and rectangular types of abutment screw drivers were used. The original abutment screw drivers were modified by grinding acute angle of the screw driver tip (modified drivers). Group 1 : hexagonal type abutment screw and original driver Group 2 : hexagonal type abutment screw and modified driver Group 3 : rectangular type abutment screw and original driver Group 4 : rectangular type abutment screw and modified driver UCLA lab analogues were located in acrylic resin block. The angulations of them were 0 and 20 degrees. The times needed for insertion were measured. Group 1 and 3 were used as controls. Results. 1. Group 2 showed shorter insertion time than group 1, regardless of implant angulations (p<.05). 2. Group 4 showed shorter insertion time than group 3, regardless of implant angulations (p<.05). Conclusion. Modified abutment screw drivers required less amount of time to insert screw driver into abutment screw head. Modification of abutment screw driver was beneficial.
참고문헌 (11)
- "Failuresand complications in 92 consecutively in-serted overdentures supported by Bra-nemark implants in severely resorbededentulous maxillae:a study from prosthetictreatment to first annual check-up", 7(2), pp.162~7 (1992)
- "Optimum torque values for implant abut-ment screws", 72, pp.191~3 (1993)
- "The longitudinalclinical effectiveness of osseointegrateddental implants", pp.185~94 (1990)
- "Torque required to loosen single-tooth implant abutment screw before and aftersimulated function", pp.435~9 (1993)
- "Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants", 7(1), pp.26~33 (1992)
- "Clinical evaluation of single-tooth restorations supported by osseointegrated implants", pp.179~83 (1994)
- "Single-tooth restorations supported by osseointegrated implants:resultsand experiences from a prospective study after 2 to 3 years", 10, pp.702~11 (1995)
- "Implants in partially edentulous patients", pp.49~56 (1992)
- "3-year follow-up study on single implant treatment", pp.203~8 (1993)
- "A swedishmulticenter study of 8139 consecutively inserted Nobelphama implants", pp.287~96 (1988)
- "Tightening characteristic for screwed joint in osseointegrated dental implant", 71, pp.592~5 (1994)