논문KCI 등재
Surface characteristics of anodic oxidized titanium according to the pore size
1
조회
0
다운로드
0
인용
0
참고문헌
주제분류치의학
참고문헌 (39)
- "Correlation betweensubstratum roughness and wettability cell adhesion and cell migration", 36, pp.99~108 (1997)
- "Optimization of surface micro-morphology for enhanced osteoblast responsesin vitro", 7, pp.302~310 (1992)
- "Modulationof matrix vesicle enzyme activity and phos-phatidylserine content by ceramic implant ma-terials during endosteal bone healing", 51, pp.429~437 (1992)
- "Uptake and biodistributionof 99mtechnetium methylene 32P diphosphonateduring endosteal healing around titanium stainless steel and hydroxyapatite implants in rat tibialbone", 16, pp.1373~1380 (1995)
- "Aspect of surface physics ontitanium implants"
- "Microarray based expression analysis of human osteoblast like cell response to anodized titanium surface" (2004), Seoul National University
- "Osseointegrated titanium implants", 52, pp.155~170 (1981)
- "Optimum surface properties of oxidized implants for reinforcement of osseointegration surface chemistry oxide thickness porosity roughness and crystal structure", 20, pp.349~359 (2005)
- "Immediateloading of Branemark System with TiUnite and machined surfaces in the posterior mandible a randomized open ended trial", 5(1), pp.57~63 (2003)
- "Immediateocclusal loading of branemark MkIV TiUnite implants placed predominantly in soft bone 1yearresults of a prospective clinical study", 5(1), pp.47~56 (2003)
- "Immediate occlusalloading of Branemark implants applied in variousjawbone regions a prospective 1year clinicalstudy", 3, pp.204~213 (2001)
- "Osseointegration enhanced by chemical etchingof the titanium surface", 8, pp.442~447 (1997)
- "The Interface between bone and metalswith different surface properties" (1997), teborg university
- "Bone response to surface modified titanium implants studies on the tissue response after 1 year to machined and electropolished implants with different oxide thickness", 8, pp.721~729 (1997)
- "Resonance frequency and removaltorque analysis of implants with turned and anodized surface oxides", 13, pp.252~259 (2002)
- "Influence of surface characteristics onbone integration of titanium implants.A histo-morphometric study in miniature pigs", 29, pp.889~902 (1991)
- "Surfacecharacterizations of variously treated titaniummaterials", 16, pp.333~342 (2001)
- "Clinical evaluation ofdental implants with surfaces roughened by anodicoxidation dual acidetched implants and machined implants", 20, pp.793~798 (2005)
- "Comparativepush-out data of bioactive and non-bioactive ma-terials interface", orgi(m), pp.350~356 (1991), University ofToronto Press
- "Histomorphometricevauation of the thin hydroxyapatite layer formedthrough anodization followed by hydrothermaltreatment", 35, pp.199~206 (1997)
- "Properties of a new porous oxide surface on titanium implants", 1, pp.5~8 (2001)
- "Histologic evaluation of bone response to oxidized and turned titanium microimplants in human jawbone", 18, pp.341~348 (2003)
- "Effect of topography and compositionof titanium surface oxides on osteoblast responses", 25, pp.4087~4103 (2004)
- "Characteristicsof the surface oxides on turned and electrochem-ically oxidized pure titanium implants up to dielecticbreakdown", pp.11879~11886
- "Osseointegration of anodized titaniumimplants" (2003), Seoul National University
- "Effectof titanium oxide passive film crystal structure thickness and crystallinity on C3 adsorption", 11, pp.73~80 (1996)
- "Substratum surface topography alters cell shape and regulates fibronectin mRNA level mRNA stability secretion and assembly in human fibroblasts", 108, pp.1563~1573 (1995)
- "Effect of roughness fibronectin andvitronectin on attachment spreading and proliferation of human osteoblast like cells Saos2 ontitanium surface", 64, pp.499~507 (1999)
- "Cytoskeletal changes in fibroblast adhesion and de-tachment", 43, pp.379~390 (1980)
- "Effect of titanium surface roughness onproliferation differentiation and protein synthesis of human osteoblast like cells", 29, pp.389~401 (1995)
- "Bioactive metals preparation and properties", 15, pp.99~107 (2004)
- "Implant fixation improved by close fit", 59(3), pp.272~275 (1988)
- "Enhanced ex-tracellular matrix production and mineralizationby osteoblasts cultured on titanium surfaces in vit-ro", 101, pp.209~217 (1992)
- "Surface characteristics and structure of anodic oxide films containing Ca and P on a titanium implant material", 60, pp.333~338 (2002)
- "The optimum pore size for the fixation of poroussurfaced metal implants by the ingrowth of bone", 150, pp.263~270 (1980)
- "Interface mechanics of porous ti-tanium implants", 15, pp.73~82 (1981)
- "The humanbone oxidized titanium implant interface A lightmicroscopic scanning electron microscopic and energy dispersive X-ray study of clinically retrieveddental implants", 7(1), pp.36~43 (2005)
- "Effect of surface topology on the osseointegration of implant materials in trabecular bone", 29, pp.1567~1575 (1995)
- "Cellular reactions of os-teoblasts to micron- and submicron-scale porous"
관련 논문AI추천
Characterization of Titanium Implant Anodized in Various ElectrolytesByung-Won, Hyng-SunKim, Joon-Bong, Won-IlCho, Yin-SikHur한국전기화학회 · 전기화학회지2002 · 제5권 제2호Surface analyses of titanium substrate modified by anodization and nanoscale Ca-P deposition김명주, 김창회, 이정민, 임영준대한치과보철학회 · 대한치과보철학회지2007 · 제45권 제6호양극산화에 의한 티타늄 산화막의 표면 특성 및 생체 활성에 관한 연구이상한, 조인호대한치과보철학회 · 대한치과보철학회지2007 · 제45권 제1호Biological responses of osteoblast-like cells to different Titanium surface by anodizing modification김명주, 김창회, 박현주, 임영준대한치과보철학회 · 대한치과보철학회지2005 · 제43권 제6호Surface characteristics and bioactivity of an anodized titanium surface김결, 김영준, 이보아, 정현주, Xing-Hui Piao대한치주과학회 · Journal of Periodontal & Implant Science2013 · 제43권 제4호양극산화처리를 통한 다공성 임플랜트 표면의 표면거칠기 증대에 대한 연구송광엽, 윤태호대한치과보철학회 · 대한치과보철학회지2006 · 제44권 제5호
이 간행물의 다른 논문 (6건)
Marginal fit of the digident cad/cam zirconia ceramic crowns양재호, 김용선pp. 275-283Photocatalytic antifungal activity against Candida albicans by TiO2 coated acrylic resin denture base정재헌, 김희중, 양지연pp. 284-294Application of finite element analysis to evaluate implant fractures임영준, 김창회, 김양수, 김명주pp. 295-313A study on the correlation between implant stability values and initial insertion torque이종혁, 양재호pp. 314-324Effect of implant designs on insertion torque and implant stability quotient(ISQ)value박춘매, 한종현, 곽재영, 김성균, 허성주, Xian-Hao Fangpp. 325-332