심혈관 OCT의 임상적 응용
Clinical Applications of Intracoronary OCT (Invited Paper)
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
심혈관 질환은 심장마비의 가장 흔한 원인으로 관상동맥의 협착으로 심근에 산소와 영양분을 제대로 공급하지 못하게 되어 발생하게 된다. 이를 내과적으로 치료하기 위해 심혈관 중재술이 시행되는데 이때 스텐트 삽입 여부, 위치, 크기, 그리고 스텐트삽입 후 혈관벽과의 밀착 여부를 평가하기 위해 혈관 내 광간섭단층촬영(OCT, optical coherence tomography) 내시경 진단검사를시행한다. 본 논문에서는 이러한 심혈관 OCT 원리와 기술 동향, 그리고 실제 의료현장에서 심혈관 OCT의 임상적 응용 및 활용가치를 소개하고자 한다.
Abstract
The most common cause of a heart attack is known as coronary artery disease, which narrows the arteries and reduces theblood flow to the heart. To treat coronary artery stenosis, percutaneous coronary intervention (PCI) (a nonsurgical procedure toinstall a stent, which holds the artery wall open) is performed. Intracoronary optical coherence tomography (OCT) is acatheter-based, invasive optical imaging system. To determine whether PCI is appropriate, and to perform stent evaluation in acatheterization laboratory, OCT examinations are carried out. This review details the fundamental principles and technologicalstatus of intracoronary OCT imaging, and discusses the ongoing clinical applications to determine the benefits of OCT-guided PCI.
참고문헌 (25)
- R. Lozano, "Global and regional mortality from 235 causes of death for 20 age groups in 1990 and 2010: a systematic analysis for the global burden of disease study 2010", Lancet, 380, pp.2095~2128 (2012)
- G. S. Mintz, "Clinical utility of intravascular imaging and physiology in coronary artery disease", J. Am. Coll. Cardiol, 64, pp.207~222 (2014)
- D. Huang, "Optical coherence tomography", Science, 254, pp.1178~1181 (1991)
- R. Leitgeb, "Performance of fourier domain vs. time domain optical coherence tomography", Opt. Express, 11, pp.889~894 (2003)
- S. H. Yun, "High-speed optical frequency domain imaging", Opt. Express, 11, pp.2953~2963 (2003)
- H. C. Lowe, "Intracoronary optical diagnostics current status, limitations, and potential", J. Am. Coll. Cardiol. Cardiovasc. Interv, 4, pp.1257~1270 (2011)
- T. Wang, "Intravascular optical coherence tomography imaging at 3200 frames per second", Opt. Lett, 38, pp.1715~1717 (2013)
- H. S. Cho, "High frame-rate intravascular optical frequency-domain imaging in vivo", Biomed. Opt. Express, 5, pp.223~232 (2014)
- R. Ross, "Atherosclerosis-an inflammatory disease", New England Journal of Medicine, 340, pp.115~126 (1999)
- A. V. Finn, "Concept of vulnerable", unstable plaque, 2010, pp.30, 1282~1292
- N. H. Pijls, "Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenosis", New England Journal of Medicine, 334, pp.1703~1708 (1996)
- N. H. Pijls, "Coronary pressure measurement after stenting predicts adverse events at follow-up: a multicenter registry", Circulation, 105, pp.2950~2954 (2002)
- J. E. Sousa, "Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-dimensional intravascular ultrasoundstudy", Circulation, 103, pp.192~195 (2001)
- S. Garg, "Coronary stents: looking forward", J. Am. Coll. Cardiol, 56, pp.S43~S78 (2010)
- T. F. Lüscher, "Drug-eluting stent and coronary thrombosis biological mechanisms and clinical implications", Circulation, 115, pp.1051~1058 (2007)
- G. Guagliumi, "Examination of the in vivo mechanisms of late drug-eluting stent thrombosis: findings from optical coherence tomography and intravascular ultrasound imaging", J. Am. Coll. Cardiol. Intv, 5, pp.12~20 (2012)
- J. Ha, "Assessing neointimal coverage after DES implantation by 3D OCT", J. Am. Coll. Cardiol. Img, 5, pp.852~853 (2012)
- J. S. Kim, "The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis", JACC Cardiovasc. Interv, 7, pp.641~651 (2014)
- V. Farooq, "Three-dimensional optical frequency domain imaging in conventional percutaneous coronary intervention:the potential for clinical application", Eur. Heart J, 34, pp.875~885 (2013)
- J. Ha, "3D OCT versus FFR for jailed side-branch ostial stenosis", JACC Cardiovasc. Imaging, 7, pp.204~205 (2014)
- A. M. Fard, "Optical coherence tomography-near infrared spectroscopy system and catheter for intravascular imaging", Opt. Express, 21, pp.30849~30858 (2013)
- H. Yoo, "Intra-arterial catheter for simultaneous microstructural and molecular imaging in vivo", Nat. Med, 17, pp.1680~1684 (2011)
- S. D. Giattina, "Assessment of coronary plaque collagen with polarization sensitive optical coherence tomography (PS-OCT)", International Journal of Cardiology, 107, pp.400~409 (2006)
- S. Liang, "Trimodality imaging system and intravascular endoscopic probe: combined optical coherence tomography, fluorescence imaging and ultrasound imaging", Opt. Lett, 39, pp.6652~6655 (2014)
- M. I. Papafaklis, "vivo assessment of the three-dimensional haemodynamic microenvironment following drug-eluting bioresorbable vascular scaffold implantation in a human coronary artery: fusion of frequency domain optical coherence tomography and angiography", EuroIntervention (2013)