대용량 포집장치를 적용한 다이옥신 수질분석과정에서 측정불확도의 추정
Uncertainty Assessment for PCDDs/Fs Measurement using Large Volume Sampler
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Uncertainties in measurements of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in ambient waters were estimated using large volume water sampler with polyurethane foam. According to the guidance of uncertainity measurement by International Standardization Organization, optimal procedure model was set up and then calculation and combination of each uncertainty source were performed. Factors affecting PCDD/F concentrations in ambient waters were selected as uncertainties of sampling, spike of internal standards, extraction of polyurethanefoam (PUF), and instrumental analysis. The major factor for each uncertainty procedure was instrumental analysis, and in the order of extraction of PUF, spike of internal standards and sampling. Relative amount of the uncertainty in the present study was estimated to be 13% to the measured concentrations of PCDD/Fs, consistent with the values for serum analysis in an earlier study.
Abstract
Uncertainties in measurements of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in ambient waters were estimated using large volume water sampler with polyurethane foam. According to the guidance of uncertainity measurement by International Standardization Organization, optimal procedure model was set up and then calculation and combination of each uncertainty source were performed. Factors affecting PCDD/F concentrations in ambient waters were selected as uncertainties of sampling, spike of internal standards, extraction of polyurethanefoam (PUF), and instrumental analysis. The major factor for each uncertainty procedure was instrumental analysis, and in the order of extraction of PUF, spike of internal standards and sampling. Relative amount of the uncertainty in the present study was estimated to be 13% to the measured concentrations of PCDD/Fs, consistent with the values for serum analysis in an earlier study.
참고문헌 (14)
- H. Otaka, , Anal. Bioanal. Chem, 378, pp.1854~1860 (2004)
- 최재원, "디스크타입 고상추출장치 및 컬럼커플링을 이용한 물시료의 PCDD Fs 간이분석법", 한국물환경학회지, 22(5), pp.879~886 (2006), 한국물환경학회
- J.W. Choi, , J. Chromatography. A, 1157, pp.17~22 (2007)
- H.K. Kim, , Org.Compd, 51, pp.135~140 (2001)
- R. Gotz, , Chemosphere, 28, pp.63~74 (1994)
- "Guide to the Expression of uncertainty in Measurements", ~ (1993), ISO
- 우진춘, , 한국분석과학회지, 13(2), pp.19A~26A (2000)
- Method 1613,US Environmental Protection Agency(EPA), "Method 1613, US Environmental Protection Agency (EPA)", ~ (1994)
- "JIS K 0312, Japanese Industrial Standards Committee (JIS)" (2005), Tokyo, Japan
- Method 3545-A,US Environmental Protection Agency(EPA), "Method 3545-A, US Environmental Protection Agency (EPA)", ~ (1986)
- J.W. Choi, , ~, in press
- "Application Note 323, DIONEX", ~ (1999)
- 문동호, "다이옥신 숙련도 시험용 시료의 제조", 한국환경분석학회지, 8(3), pp.143~153 (2005), 한국환경분석학회
- 문수정, , 한국분석과학회지, 16(6), pp.475~482 (2003)